The Magiglo series of decorative fires are suitable to be installed into a
masonry or approved prefabricated fireplace and are designed to operate
with Natural and ULPG gases only. Approval Number GMK10098.
VERSION 21B (ODS MODELS ONLY)
C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAGIGLO MAG360 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Real Flame MAGIGLO MAG360

  • Page 1 MAGIGLO SERIES ® INSTALLATION & OPERATING MANUAL REFER THIS MANUAL FOR MAG360, MAG400, MAG540, MAG750 The Magiglo series of decorative fires are suitable to be installed into a masonry or approved prefabricated fireplace and are designed to operate with Natural and ULPG gases only. Approval Number GMK10098. VERSION 21B (ODS MODELS ONLY)
  • Page 2 WARRANTY INFORMATION The benefits provided to you under the following warranty are in addition to any other rights and remedies available to you under the law. 1. Warranty during the first 15 years from the date of purchase (Firebox Warranty Period), there is a defect in the firebox of the Gas Burner;...
  • Page 3 INSTALLATION NOTICE The installation of this appliance is only to be carried out by an authorised person in accordance with the Manufacturer’s Instructions, local gas fitting regulations, AS/NZS5601.1-2013 installation code for gas burning appliances and any other relevant statutory regulations. In all cases the installation of this appliance shall meet the requirements as set out in AS/NZS5601.1-2013 NOTE: A slight smell may be apparent for the first few hours of use.
  • Page 4: Table Of Contents

    CONTENTS Contents .........................4 Data Plate .......................5 Dimensions ......................6 Installation Instructions ...................9 Lighting Instructions....................10 Commissioning Procedure..................12 Typical Type 1 Installation to existing chimney .............13 Type 1 Installation into Victorian/Federation grate..........14 Typical Type 2 Installation of Prefabricated Fire Box into existing chimney ..15 User Instructions....................16 Troubleshooting ....................16 Conversion details ....................17...
  • Page 5: Data Plate

    DATA PLATE (Affixed to the base of the unit for reference to gas pressure & consumption) BURNER MODEL NATURAL GAS ULPG INJ. SIZE MJ/Hr TPP (kPa) INJ. SIZE MJ/Hr TPP (kPa) 2.40 0.80 1.20 2.60 2.50 0.80 1.30 2.70 2.60 0.80 1.30 2.70...
  • Page 6: Dimensions

    DIMENSIONS Magiglo 320 Burner PLAN FRONT Magiglo 360 PLAN FRONT...
  • Page 7 DIMENSIONS Magiglo 400 Burner PLAN FRONT Magiglo 540 PLAN FRONT...
  • Page 8 DIMENSIONS Magiglo 750 PLAN FRONT...
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS IMPORTANT This product is fitted with an OXYGEN DEPLETION SYSTEM which is an INTEGRAL PART OF THE PILOT. You must maintain the correct pressure for the oxygen depletion system to operate correctly (see data plate on page 5). When checking gas pressure at the appliance ALL OTHER GAS APPLIANCES IN PREMISES MUST BE OPERATING AT THE SAME TIME.
  • Page 10: Lighting Instructions

    FOR YOUR SAFETY READ BEFORE LIGHTING The appliance has a pilot which must be lit using the piezo ignition, when lighting the pilot follow the instructions exactly. Before lighting the appliance check for gas leaks. Use only your hand to push in and turn the gas control knob, never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician.
  • Page 11 LIGHTING INSTRUCTIONS - Magiglo 400, 540 & 750 To light the pilot, press in and turn the gas control knob anticlockwise to the pilot position. (Fig 1) Fig 1 Depress the knob and press the red button. If the pilot lights, continue to depress knob for 20 seconds and release.
  • Page 12: Commissioning Procedure

    COMMISSIONING PROCEDURE Once the fire is installed and operational the installer must check for spillage. Carry out the lighting procedure and turn the fire to high. Allow to warm up for 10 minutes and then using a smoke match set 25mm down and 25mm inside of the fire opening run the match across the width of the opening to check that all of the smoke is drawn away.
  • Page 13: Typical Type 1 Installation To Existing Chimney

    TYPICAL TYPE 1 INSTALLATION TO EXISTING CHIMNEY Optional For Type 1 installations models with an ODS pilot must be used. 225mm DIA GAS COWL Smoke match spillage test. Ensure gas log fire is set back into fire place in order that no waste products come into the room.
  • Page 14: Type 1 Installation Into Victorian/Federation Grate

    TYPE 1 INSTALLATION INTO VICTORIAN/FEDERATION GRATE EDWARDIAN/VICTORIAN GRATE AIR TUBES COALS CERAMIC BLANKET BURNER PORT CUT OUT SECTION CONTROL BASE GRATE FRONT IRON COAL PLACEMENT Place Air Tubes 5mm behind Burner Port and space evenly. (cut to size if too long). AIR TUBES BURNER 5mm GAP...
  • Page 15: Typical Type 2 Installation Of Prefabricated Fire Box Into Existing Chimney

    TYPICAL TYPE 2 INSTALLATION OF PREFABRICATED FIRE BOX INTO EXISTING CHIMNEY FOR INSTALLATION OF FIRE BOX REFER TO MANUFACTURER’S SPECIFICATIONS. SEAL FLANGE TO BRICKWORK 225mm Dia Gas Cowl Existing Chimney Flue to the required size if chimney does not draw properly Seal flange to brickwork Gather Convection Box...
  • Page 16: User Instructions

    2. Check for faulty thermocouple. 3. Excessive draught can cause flame to extinguish. WARNING Magiglo burn with a real flame which should be treated with same respect as any naked flame. A fireguard should be used for the protection of children and the elderly.
  • Page 17: Conversion Details

    CONVERSION DETAILS NATURAL GAS TO ULPG Turn appliance off. Turn gas supply off. Remove regulator cap and adjustment nut. Remove regulator spring and replace with correct gas type spring. Replace regulator cap. Remove pilot assembly cover. Remove from valve, oxy pilot thermocouple. Remove from pilot, spark lead and pilot gas tube.
  • Page 18: Parts List

    PARTS LIST PART No. DESCRIPTION PART No. 1/2˝ to 3/8˝ Hex Nipple BM733 Control Valve, Eurosit 630 Valve 5/16˝ 90O Union Elbow Regulator SC-75 S.I.T. ODS Pilot Assembly (Natural Gas) 1/4˝ Nut and Olive S.I.T. ODS Pilot Assembly (Propane Gas) Injector Holder Stem Injector 1/2˝...
  • Page 20: Glen Dimplex Contact Information

    www.realflame.com.au 1300 554 155...