Gima AlcoPatrol AP338 Manual
Gima AlcoPatrol AP338 Manual

Gima AlcoPatrol AP338 Manual

Professional breath alcohol analyzer with fuel cell sensor
Hide thumbs Also See for AlcoPatrol AP338:

Advertisement

Quick Links

Professional Breath Alcohol Analyzer
Model: FiT AP-338
Version: Version 1.4
IMPORTANT: Many factors (e.g. environment gas residue, smoke & various smell
mouth, etc...) may affect the Blood Alcohol Concentration (BAC) level, so the Readings are For
Reference Only.
Neither the reseller nor manufacturer accept any liability arising from the use of this unit.
DO NOT drink before you drive!
AP338 (GIMA 24486)
Manufacturer:
A&A Product Manufacturing Limited
Workshop 9, 18/F, Tower A, New Trade Plaza, 6 On Ping Street, ShaTin,
New Territories, Hong Kong
Made in China
With Fuel Cell Sensor
Imported by:
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
in human

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AlcoPatrol AP338 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gima AlcoPatrol AP338

  • Page 1 Blood Alcohol Concentration (BAC) level, so the Readings are For Reference Only. Neither the reseller nor manufacturer accept any liability arising from the use of this unit. DO NOT drink before you drive! AP338 (GIMA 24486) Manufacturer: Imported by: A&A Product Manufacturing Limited Gima S.p.A.
  • Page 2: Table Of Contents

    Contents Page …………………………………………………… Measuring instrument …………………………………………………… Packing List …………………………………………………… Basic Scientific Principles …………………………………………………… Maintenance …………………………………………………… Intended Use General Conditions …………………………………………………… Power & Charging …………………………………………………… …………………………………………………… Operation instructions …………………………………………………… Active Test Quick Test …………………………………………………… Test Record …………………………………………………… Sensor Test …………………………………………………… System Setting ……………………………………………………...
  • Page 3: Measuring Instrument

    Measuring instrument 1. LCD display with touch panel 2. Power Key 3. Back Key 4. Home Key 5. Function Key 6. Camera 7. Mouth piece 8. Inner tube 9. USB Jack (Connect computer/Charging) 10. Printer 11. Gas Outlet 1 12. Gas Outlet 2...
  • Page 4: Packing List

    Packing list 1. Measuring instrument 2. Mouthpiece, 10 pcs 3. Blowing Funnel, 1pc 4. Leather sheath, 1pc 5. Printer paper, 4pcs 6. USB cable , 1pc 7. Car adaptor, 1pc 8. USB Charger,1pc 9. CD for Download software,1pc 10.User manual 1pc...
  • Page 5: Basic Scientific Principles

    Thanks for purchasing our AP-338 Professional Fuel Cell Digital Alcohol Analyzer. AP-338 gives you a precision digital indication of your breath alcohol content and thus your possible concentration of intoxication. To achieve the high accuracy, user should study this manual carefully. And any use of the AP338 requires full understanding and strict observation of these instructions.
  • Page 6: Power & Charging

    Important: DO NOT EAT, DRINK, OR SMOKE FOR 15 MINUTES PRIOR TO UNDERTAKING A TEST. FAILURE TO DO SO MAY IMPAIR RESULTS AND DAMAGE THE UNIT. REMEMBER: NEVER DRINK & DRIVE – THE ONLY SAFE LEVEL IS ZERO Power & Charging ●If the battery symbol on the display indicates “empty”, please charge it as soon as possible.
  • Page 7: Operation Instructions

    Operation instructions 1. Active Test: Under this test mode, the device will initialize the sensor condition. In some case, it need take few seconds to 2 minutes. 1.1. I nsert a new mouthpiece in CORRECT orientation into the inner tube chamber inlet. 1.2.
  • Page 8 1.7. Press “Save” to input the relevant pictures below: After inputted the relevant information, the Print or Retest interface will display on the LCD. Press “Print” key to print out the test result or Press “Retest” to start another test or Press “Return” key to return back. The Printout contains: instrument name &...
  • Page 9: Quick Test

    2. Quick Test: Under this mode, the device allow to test without initialize sensor condition. Eg: temperature & residual alcohol. It can ready to test within 1 second. Repeat the 1.1 – 1.7 to do the quick breath alcohol test. Passive test: Press “Power”...
  • Page 10: Sensor Test

    4. Sensor Test: Press “Sensor Test” icon and enter the sensor test screen. Press “Auto” icon, then blow alcohol air (about 0.05%BAC) into chamber through the blow tube for about six seconds and observe the sensor sensitivity & waveform as attached. If the cure is a straight line, it means the sensor already lost the sensitivity and need to change a new sensor.
  • Page 11 ② “CAL Flow” Calibrate breath blowing flow/ pressure. Please blow to the device use 15 Liter/minute flow for 6 seconds, with device has Long “beep..!” Sound. A “beep beep” sound when finish. Screen shows flow data, press “Save” to save the date. Or press “Restart” to try again. Or press “return” icon to exit the flow calibration menu.
  • Page 12 ⑤ “Set Unit” Set the unit to Permillage ( ‰ AC), Percentage ( % AC) and mg/L, mg/ml, mg/100ml and g/l. as picture. For advanced user, it may set the BrAC ratio: 2100, 2000, 2200, 2300. ⑥ “USB CONNECT PC” User can download the records and photos to the PC computer with a PC software and USB cable.
  • Page 13: Gps

    ⑨ “SET WIFI” Scan and connect your Wi-Fi network. GPS: If user want the test result record with GPS coordinate position, please enter into the “ ”menu, to start the GPS postion detection. After successful locating, then make the alcohol test with GPS record. See picture below for your reference.
  • Page 14: Specification

    Specification 1. product description: Law Enforcement Alcohol Tester with Electrochemical / Fuel Cell Sensor 2. Built in thermal printer: Heat transfer printer 3. Display: 4.5 Inch iPS LCD display 4. Input: Touch Panel 5. Quick and precise analysis: Ensure a high sensitivity to alcohol and stable & reliable working life. 6.
  • Page 15: Calibration And Service

    Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by bringing it to a specific recycling point for electric and electronic equipment. GIMA WARRANTY TERMS The Gima 12-month standard B2B warranty applies. P/N: 338-01821 V1.4...

This manual is also suitable for:

24486