Hochiki America Corporation HCV Series Installation And Operation Manual

Conventional fire alarm system

Advertisement

Quick Links

HCV Series

Conventional Fire Alarm System

(HCV-2, HCV-4, HCV-8)

Installation and Operation Manual

Hochiki America Corporation
7051 Village Drive, Suite 100
Version 1.03
Buena Park, CA 90621-2268
Created: 02/04/2010
714.522.2246 Corporate Headquarters
Updated: 11/08/2012
800.845.6692 Technical Support
HA-06-228
http://www.hochiki.com
HCV Series I & O Manual
1
V1.03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HCV Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hochiki America Corporation HCV Series

  • Page 1: Hcv Series

    (HCV-2, HCV-4, HCV-8) Installation and Operation Manual Hochiki America Corporation 7051 Village Drive, Suite 100 Version 1.03 Buena Park, CA 90621-2268 Created: 02/04/2010 714.522.2246 Corporate Headquarters Updated: 11/08/2012 800.845.6692 Technical Support HA-06-228 http://www.hochiki.com HCV Series I & O Manual V1.03...
  • Page 2: Table Of Contents

    20.2 Batt fail ........................... 19   20.3 CPU fault ........................19   20.4 Aux 24V fault ..........................19   20.5 Batt low .......................... 19   20.6 Earth fault HCV Series Panel I & O Manual Page 2 of 24 V1.03...
  • Page 3 20.9 Comms fault 21. Power supply ....................... 20  22. Maintenance ........................ 21  23. Zone designation label ....................21  24. Record of Configuration ....................22  25. Warranty ........................24  HCV Series Panel I & O Manual Page 3 of 24 V1.03...
  • Page 4: Introduction

    1. Introduction The HCV series CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2, 4 and 8 zone control panels. All control panels are available in two versions: HCV CP range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided).
  • Page 5: Technical Specification

    15.5 to 17.5 volts Zener clamp detector base to be used Cabling FP200 or equivalent (maximum capacitance 1uF Metal cable glands must be used maximum inductance 1 millihenry) HCV Series Panel I & O Manual Page 5 of 24 V1.03...
  • Page 6 Table 7 - Compatible I.S. barriers Model Type Manufac turer MTL5561 DETECTION ZONE GALVANIC ISOLATOR MTL 7778ac SOUNDER CIRCUITS SI AND S2 ONLY Note: Use galvanic isolator with Hochiki detectors only. HCV Series Panel I & O Manual Page 6 of 24 V1.03...
  • Page 7: Using Intrinsically Safe Barriers

    Zone classification rating (Gas class) this will be specified on the system diagram. Figure 1. Detection zone wiring through an MTL5561 I.S .barrier Figure 2. Sounder circuit wiring through an MTL 7778ac I.S. barrier HCV Series Panel I & O Manual Page 7 of 24 V1.03...
  • Page 8: Control Panel Fascia

    It is most important that the polarity of the red and black wires is observed as wrong connection of these will damage the control panel HCV Series Panel I & O Manual Page 8 of 24 V1.03...
  • Page 9: Connecting To The Circuit Board

    C 56 TH 1 SERIAL NUMBER R 75 D 1008 ISSUE 06 R 76 LED 17 LED 35 LED5 LED4 LED3 LED6 LED7 R 70 SOFTWARE VERSION LABEL HCV Series Panel I & O Manual Page 9 of 24 V1.03...
  • Page 10: Detection Zone Wiring

    (see figure 5 below). At least one sounder should be fitted to each detection zone. Each zone can be configured individually as a 2-wire type zone or a non 2-wire type zone using configuration options C1 to C8. HCV Series Panel I & O Manual Page 10 of 24 V1.03...
  • Page 11: Nac Circuit Wiring

    To activate these inputs, the remote 0 Volt (R0V) supply must be connected to the input via a normally open switch or contact and via a resistance of no greater than 100 ohms. All of the remote control inputs are non-latching. HCV Series Panel I & O Manual Page 11 of 24 V1.03...
  • Page 12: Aux 24V Dc Supply

    ENTER button to accept each remote annunciator that has been found. When all remote annunciator have been added, set the main panel Write Enable switch to off. Press the Watchdog reset switch on the main panel. HCV Series Panel I & O Manual Page 12 of 24 V1.03...
  • Page 13: Connection To Auxiliary Boards

    1 has been found. HCV Series Panel I & O Manual Page 13 of 24 V1.03...
  • Page 14: Panel Operation

    Failure of the mains power, disconnection of the standby battery or high impedance in the charging circuit will cause the Fault and Power Fault LEDs to light indicating an abnormality in the power supply to the control panel. 16.8 System fault HCV Series Panel I & O Manual Page 14 of 24 V1.03...
  • Page 15 Disablements and zone tests are cleared by repeating the sequence that is used to select them, i.e. the "db" function (for example) toggles between sounders disabled and sounders enabled. HCV Series Panel I & O Manual Page 15 of 24...
  • Page 16: Configuration Options

    SOUNDER DELAY TIME = 5 MINUTES SOUNDER DELAY TIME = 6 MINUTES SOUNDER DELAY TIME = 7 MINUTES SOUNDER DELAY TIME = 8 MINUTES SOUNDER DELAY TIME = 9 MINUTES HCV Series Panel I & O Manual Page 16 of 24 V1.03...
  • Page 17 ZONE 7 SHORT CIRCUIT INDICATES ALARM ZONE 8 SHORT CIRCUIT INDICATES ALARM ZONE 1 NON-LATCHING Renders the zone self-resetting so that it can be used to receive signals from ZONE 2 NON-LATCHING HCV Series Panel I & O Manual Page 17 of 24 V1.03...
  • Page 18: Watchdog Reset Switch

    This fault can only be cleared by pressing the WATCHDOG RESET button on the PCB inside the control panel. The control panel buzzer can not be silenced and will continue to sound until the watchdog activation is reset. HCV Series Panel I & O Manual Page 18 of 24 V1.03...
  • Page 19: Processor Reset Switch

    20.8 S1 fault and S2 fault Indicates a short or open circuit on sounder outputs. Remove wiring and refit end of line resistors. Check sounder circuit wiring. HCV Series Panel I & O Manual Page 19 of 24 V1.03...
  • Page 20: Comms Fault

    THE TERMINAL BLOCK WITH A CABLE TIE BLACK BATTERY LEAD TO - GREY LINK RED BATTERY TERMINAL LEAD TO + TERMINAL Figure 9 – Mains and battery connections HCV Series Panel I & O Manual Page 20 of 24 V1.03...
  • Page 21: Maintenance

    All HCV CP control panels are supplied with a zone designation label onto which zone designations can be written. This enables each zone to be given a text description allowing easier identification of any zones showing an abnormal condition. HCV Series Panel I & O Manual Page 21 of 24 V1.03...
  • Page 22: Record Of Configuration

    Detection threshold changed for use with IS barrier CONFIGURE Z2 FOR I.S BARRIER CONFIGURE Z3 FOR I.S BARRIER CONFIGURE Z4 FOR I.S BARRIER CONFIGURE Z5 FOR I.S BARRIER CONFIGURE Z6 FOR I.S BARRIER HCV Series Panel I & O Manual Page 22 of 24 V1.03...
  • Page 23 ZONE 7 WILL NOT OPERTATE FIRE RELAY SOFTWARE VERSIONS HCV242.HEX hex and above only ZONE 8 WILL NOT OPERTATE FIRE RELAY NOTE: Setting the options marked with asterisks does not comply with EN54-2 HCV Series Panel I & O Manual Page 23 of 24 V1.03...
  • Page 24: Warranty

    25. Warranty Hochiki America Corporation manufactured equipment is guaranteed to be free from defects in materials and workmanship for a period of three (3) year from date of original shipment. HOCHIKI will repair or replace, at its option, any equipment which it determines to contain defective material or workmanship.