ACP OmniCycle Connect User Manual

Advanced active-assist cycle
Hide thumbs Also See for OmniCycle Connect:
Table of Contents

Advertisement

Quick Links

®
OmniCycle
Connect
Advanced Active-Assist Cycle
User Manual
Revised 06/12/2024
Part No. A009-295 Rev 06
This manual contains confidential and proprietary information owned by Accelerated Care Plus ("ACP") which is protected by copyright. This manual or any
portion thereof may not be photocopied, reproduced, or translated to another language without the express prior written consent of ACP. This manual may only
be used by entities that have purchased the equipment or have implemented the ACP program and are covered by an executed lease agreement containing a
confidentiality agreement, which is incorporated by reference in its entirety. This manual may not be used for any other purpose.
Any additional copies of the manual shall be ordered from ACP. No changes or modifications shall be made to the manual without prior review and written
authorization from ACP. No authorization is given to market, sell, disclose, or exploit this manual except as for purposes of using the equipment as contemplated
by the Lease Agreement.
ACCELERATED CARE PLUS MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MANUAL, INCLUDING, BUT NOT LIMITED TO,
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Accelerated Care Plus shall not be liable for
errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this Manual.
The information contained in this document is subject to change without notice.
COPYRIGHT 2010 - 2024, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OmniCycle Connect and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ACP OmniCycle Connect

  • Page 1 This manual may not be used for any other purpose. Any additional copies of the manual shall be ordered from ACP. No changes or modifications shall be made to the manual without prior review and written authorization from ACP.
  • Page 2 ® OmniCycle Connect User Manual Congratulations! ® Opting for a OmniCycle Connect was a great choice. ® This user manual will help you get to know your OmniCycle Connect better. It will safely guide you through all functions and control options and provide you with tips and information on how best to use your new device.
  • Page 3: Table Of Contents

    ® OmniCycle Connect - User Manual USER GUIDE ..........................5 Warnings ........................... 5 Warning categories ........................5 Symbols in the user manual ....................... 6 Symbols on the product ......................7 SAFETY AND DANGERS ......................9 INTENDED USE ........................13 3.1 Medical purpose .......................... 13 3.2 Indications and patient target group ....................
  • Page 4 ® OmniCycle Connect - User manual Leg exercise ..........................43 Upper body exercise ....................... 43 Training programs ........................43 CONTROL ELEMENTS ......................45 10.1 Control and Display Unit 7" ..................... 45 EXPERT SECTION .......................... 51 USING CONTROL AND DISPLAY UNIT 7" ................52 11.1 Sub menu ..........................
  • Page 5: User Guide

    ® OmniCycle Connect - User Manual USER GUIDE The user manual and product are marked with a variety of symbols. These symbols and their functions help you to use the product safely and efficiently. 1.1 Warnings Structure of warnings SIGNAL WORD! Type and source of danger! ...
  • Page 6: Symbols In The User Manual

    ® OmniCycle Connect - User manual 1.3 Symbols in the user manual Instructions Structure of instructions:  Instruction to do something. Presentation of results if required. Lists Structure of non-numbered lists: ❑ List level 1 – List level 2 Structure of numbered lists: List level 1 List level 1 List level 2...
  • Page 7: Symbols On The Product

    ® OmniCycle Connect - User Manual 1.4 Symbols on the product Danger due to movable Review the user manual! parts Alternating current: ® The OmniCycle Follow the user manual! Connect uses alternating current. Device of protection Manufacturer class II Can be damaged due Unique device identifier to static charging Danger due to...
  • Page 8 ® OmniCycle Connect - User manual Temperature limit: Caution fragile between -25 °C (-13 °F) and +75 °C (+165 °F) Art. No.: A009-295_Rev 06 Last update: CW24/2024...
  • Page 9: Safety And Dangers

    ® OmniCycle Connect - User Manual SAFETY AND DANGERS Danger  Before beginning training, consult a healthcare professional to clarify whether users with cardiovascular diseases are allowed to exercise with the ® OmniCycle Connect.  Use OmniCycle ® Connect exclusively with an undamaged and functional power cord.
  • Page 10 ® OmniCycle Connect - User manual appropriate range of motion (ROM). This is particularly important when using ® the OmniCycle Connect with patients recovering from fractures, total hip or knee replacement procedures, etc.  Start with an initial exercise session of no longer than 15 minutes at a low load.
  • Page 11 ® OmniCycle Connect - User Manual  In the case of paralysis, abnormal tone, muscle spasms, or instability, use ® OmniCycle Connect exclusively with the leg support option.  When device is in use, do not touch moving parts (e.g., crank, radius adjustment, foot rests, etc.).
  • Page 12 ® OmniCycle Connect - User manual  The OmniCycle ® Connect may only be operated with the mains voltage indicated on the type plate. Only connect the device to a properly grounded power socket.  Leave OmniCycle ® Connect at room temperature for 1 hour before using it for the first time or after transporting it for a longer period of time.
  • Page 13: Intended Use

    ® OmniCycle Connect - User Manual INTENDED USE General description of the product The system is a therapeutic device for circular assisted, active-assisted or active movement of the upper and lower extremities. The transition from assisted to active therapy is seamless. The system is used in a seated position, e.g., in a wheelchair or suitable therapy chair.
  • Page 14: Indications And Patient Target Group

    ® OmniCycle Connect - User manual 3.2 Indications and patient target group Indications Mild to severe impairments of the movement-related functions. 3.3 Contraindications ® Do not use OmniCycle Connect ❑ In case of severe pain during movement ❑ for patients with open wounds in contact with the device (e.g. ulcer) ❑...
  • Page 15: Biocompatibility

    ® OmniCycle Connect - User Manual 3.6 Biocompatibility ® All components and options of the OmniCycle Connect the patient will touch continuously when using the unit as intended are designed to meet the biocompatibility requirements of the applicable standards.  For any questions, contact a trained supplier/distributor. 3.7 Adverse incident reporting requirement All serious incidents occurring in connection with the product shall be reported immediately to the manufacturer and to the competent authority.
  • Page 16: Clinical Benefits

    ® OmniCycle Connect - User manual 3.8 Clinical benefits Regulation of muscle tone and reduction of spasticity It is known that physical activity can help to regulate muscle tone, so it can be assumed that rhythmic cycling training with the motor driven exercise device can achieve the goal of regulating muscle tone.
  • Page 17: Scope Of Delivery And Equipment

    ® OmniCycle Connect - User Manual Decrease of disability It is well known that physical activity helps to reduce disability, which is why exercise therapy is an essential part of the overall rehabilitation process in most rehabilitation programs, so it can be assumed, that cycling training supports the decrease of disability.
  • Page 18: Removable Parts

    ® OmniCycle Connect - User manual 4.3 Removable Parts ❑ Self-operated anti-tip protection ❑ Leg support ❑ Foot fixing ❑ Grip adapter ❑ Therapy grips ❑ Therapy grips straight ❑ Control and display unit 7”/ Control and display unit 2.7” ❑...
  • Page 19: Available Options

    ® OmniCycle Connect - User Manual 4.4 Available options Name Article no. Molded arm rest attachment - 60239 Left Molded arm rest attachment - 54565 Right 10ft Hospital Grade Power Cord 19856 Barrier Film, 3" Tubing, 63574 1200’/roll 4.5 Model overview ®...
  • Page 20: Overview

    ® OmniCycle Connect - User manual OVERVIEW (1) Therapy grips (2) Crank (application part Type BF) (3) Upper body exerciser (4) Control and display unit 7" (5) USB interface (6) Locking-pin handle for height adjustment of safety handle/upper body exerciser (7) Adjustment of inclination for safety handle/upper body exerciser (8) Foot fixing (9) Foot rest (application part type BF)
  • Page 21: Start-Up

    ® OmniCycle Connect - User Manual START-UP WARNING! Danger to life due to magnetic field!  ® OmniCycle Connect Make sure that there is no direct body contact with the in the vicinity of the pacemaker or defibrillator.  Maintain a safety distance of at least 5 cm (2 inches). 6.1 Unpacking ®...
  • Page 22 ® OmniCycle Connect - User manual  Fold up securing system 1 of leg support by foot rest.  Loosen knurled head (small ridges) screw 2.  Insert leg support 3 the right way around into slot of securing system. ...
  • Page 23: Switching On Or Off

    ® OmniCycle Connect - User Manual  Insert device plug 3 into port 1.  Connect power cord plug 4 to AC power socket. ® The OmniCycle Connect is ready for use. 6.4 Switching on or off CAUTION! Risk of injury due to the OmniCycle® Connect starting up. Make sure that no arms or legs are in the OmniCycle ®...
  • Page 24: Transporting The Omnicycle Connect

    ® OmniCycle Connect - User manual ® 6.5 Transporting the OmniCycle Connect CAUTION! Risk of injury due to incorrect transport!  ® Pull OmniCycle Connect with transport castors exclusively across even and stable floors.  ® Transport OmniCycle Connect with at least two persons up steps. ®...
  • Page 25: Operation

    ® OmniCycle Connect - User Manual OPERATION 7.1 Exercise preparation DANGER! Risk of infection due to contaminated OmniCycle® Connect!  Wear gloves during cleaning and disinfection.  Observe general precautions to prevent users from being exposed to blood-borne pathogens.  Wear personal protective equipment (gloves, masks, lab coats) when contact to bodily fluids such as saliva, blood, semen, or vaginal secretion is likely to occur.
  • Page 26: Device Base Unit

    ® OmniCycle Connect - User manual 7.2 Device base unit Variants: ❑ Device base with transport castors 1 ❑ Device base flat 2 ❑ Flat device base with wheel set 3 The following applies for all variants: – Extendible device base for enlarging the base area. –...
  • Page 27: Self-Operated Anti-Tip Protection

    ® OmniCycle Connect - User Manual 7.3 Self-operated anti-tip protection To prevent the chair/wheelchair from tipping up during the training session, attach the self-operated anti-tip protection as follows:  Move chair/wheelchair in training position in front of OmniCycle ® Connect. ...
  • Page 28: Foot Fixing/Leg Support

    ® OmniCycle Connect - User manual 7.4 Foot fixing/leg support CAUTION! Risk of injury through unprotected metal parts!  Do not remove foot rests for upper body exercise. Foot rests Secure feet in foot rests as follows:  Make sure that the OmniCycle ®...
  • Page 29 ® OmniCycle Connect - User Manual  Make sure that feet are not in foot rests.  Unscrew screws 1 using a suitable tool. – right-hand crank = right-hand thread, unscrew screws in anti-clockwise direction – left-hand crank = left-hand thread, unscrew screws in clockwise direction ...
  • Page 30 ® OmniCycle Connect - User manual  Make sure that the OmniCycle ® Connect is not in training mode.  Press release lever 3 on foot fixing 2. Retaining bracket 1 opens.  Put feet into foot rests.  Make sure that feet are correctly positioned in foot rests. ...
  • Page 31: Upper Body Exerciser

    ® OmniCycle Connect - User Manual 7.5 Upper body exerciser CAUTION! Risk of injury due to moving parts!  The therapy grip must only be gripped in the designated grey marked area during the training. Upper body exerciser ❑ Permits active or assisted exercise for the entire upper body. ❑...
  • Page 32 ® OmniCycle Connect - User manual low seating position. The height setting is lower than the safety handle (see Setting height of upper body exerciser/safety handle). Setting height of upper body exerciser CAUTION! Risk of crushing!  Take care not to pinch any fingers when pushing the pipes together. To adapt upper body exerciser/safety handle individually to body size and sitting position: ...
  • Page 33: Locking/Unlocking The Crank

    ® OmniCycle Connect - User Manual Setting distance of upper body exerciser To set the distance:  Loosen star-shaped handle 1 below upper body exerciser.  Put upper body exerciser in required horizontal position.  Tighten star-shaped handle. 7.6 Locking/unlocking the crank ®...
  • Page 34: Hand/Arm Fixing

    ® OmniCycle Connect - User manual 7.7 Hand/arm fixing Grip adapter CAUTION! Material damage due to incorrect use!  Do not use grip adapter to support body weight. CAUTION! Risk of injury due to incorrectly installed grip adapter!  Slide grip adapter onto crank axle up to the stop. ...
  • Page 35 ® OmniCycle Connect - User Manual Arm rests Variants: ❑ Arm rests for therapy grips 1 ❑ Wristbands for arm rests with bar-shaped grips 2 ❑ Tetra special grips 3 ❑ Arm rests with bar-shaped grips, vertical 4 ❑ Arm rests with bar-shaped grips, horizontal 5 Arm rests serve to secure the arms of users with ❑...
  • Page 36 ® OmniCycle Connect - User manual The wristbands for therapy grips allow paralyzed/weakened hands to be fixed quickly and easily to the therapy grips. Securing both hands is exclusively possible with the help of an assistant.  Always have an assistant supervise training sessions with two secured hands.
  • Page 37: Safety Equipment

    ® OmniCycle Connect - User Manual 7.8 Safety equipment CAUTION! Risk of injury due to damaged safety equipment. To protect thumb against injuries:  Before every training, make sure that safety equipment is working correctly.  In case of any malfunction, have the unit repaired by a trained dealer/distributor. Voice-controlled emergency stop When the arms are fixed in the upper body exerciser so that manual control is not possible:...
  • Page 38 ® OmniCycle Connect - User manual  Reconnect power cord plug. ® If the OmniCycle Connect immediately starts with the training after you have pressed the START button:  Press EMERGENCY STOP button.  Contact trained supplier/distributor and notify them about the defect. ...
  • Page 39: User Section

    ® OmniCycle Connect - User Manual USER SECTION ® The user section addresses the user and describes how to use the OmniCycle Connect. Art. No.: A009-295_Rev 06 Last update: CW24/2024...
  • Page 40: Training Requirements

    ® OmniCycle Connect - User manual TRAINING REQUIREMENTS WARNING! Danger to life due to magnetic field!  ® Make sure that there is no direct body contact with the OmniCycle Connect in the vicinity of the pacemaker or defibrillator.  Maintain a safety distance of at least 5 cm (2 inches).
  • Page 41: Correct Posture

    ® OmniCycle Connect - User Manual 8.1 Correct posture  Exercise in an upright posture.  Assume physiological training position.  If necessary, consult a healthcare professional. 8.2 Training schedule To improve mobility, strength, and endurance:  Exercise regularly.  Exercise in short units to avoid overstrain. ...
  • Page 42: Training With Omnicycle Connect

    ® OmniCycle Connect - User manual ® TRAINING WITH OmniCycle Connect CAUTION! Risk of injury due to lack of independence! ® If the user cannot operate the OmniCycle Connect without assistance:  Make sure that the user exercises exclusively with a trained assistant. CAUTION! Danger of injury due to unsuitable chair/wheelchair.
  • Page 43: Leg Exercise

    ® OmniCycle Connect - User Manual 9.1 Leg exercise WARNING! Risk of injury due to unlocked arm trainer! During leg training, the cranks of the arm trainer must be locked horizontally. Otherwise, the thigh may become trapped.  OmniCycle ® Connect enables active or assisted leg exercise.
  • Page 44 ® OmniCycle Connect - User manual Training programs/Training Training program for users with neurological disorders such as hemiplegia, Neuro paraplegia, multiple sclerosis, Parkinson's disease. (basic setting) ❑ Training type: Pre-Set resistance. ❑ Training resistance setting will remain constant within the entire rpm range. ❑...
  • Page 45: Control Elements

    ® OmniCycle Connect - User Manual CONTROL ELEMENTS 10.1 Control and Display Unit 7" (1) Button Switch training program (2) Buttons Number of revolutions (3) Button Direction of rotation (4) Button Easy entry (only activate for leg training) (5) START button (6) STOP button (7) Emergency-Stop button (8) Button Switch training program...
  • Page 46 ® OmniCycle Connect - User manual  Press button: OmniCycle ® Connect interrupts current training session STOP button (break).  Press button twice: OmniCycle ® Connect stops current training session.  Control and display unit shows report of the training session. EMERGENCY ...
  • Page 47 ® OmniCycle Connect - User Manual  First foot rest is down.  Put first foot into foot rest.  Press the START button 1 again: Crank moves into second entry position.  Second foot rest is down.  Put second foot into foot rest. ...
  • Page 48 ® OmniCycle Connect - User manual  Press : scroll forwards.  Only select training programs recommended by healthcare professional or trained supplier/distributor.  Press button combination STOP button + button ® : OmniCycle Connect Button lock activates button lock. –...
  • Page 49 ® OmniCycle Connect - User Manual Displayed parameters - 7" User Interface Display before training session Display during training session (1) Display Training program (2) Calorie display (3) Power display (4) Covered distance (5) Remaining training time (6) Status bar (7) Wireless connection present (8) Wireless connection not present (9) Bluetooth on...
  • Page 50 ® OmniCycle Connect - User manual ❑ Indicates remaining training time. Remaining training time ❑ Connection symbol without X: Existing wireless connection between a Wireless ® connection OmniCycle Connect and a PC. ❑ Connection symbol with X: No existing wireless connection between a ®...
  • Page 51: Expert Section

    ® OmniCycle Connect - User Manual EXPERT SECTION ® The expert part describes how to use the OmniCycle Connect for the trained supplier/distributor or healthcare professional. Art. No.: A009-295_Rev 06 Last update: CW24/2024...
  • Page 52: Using Control And Display Unit 7

    ® OmniCycle Connect - User manual USING CONTROL AND DISPLAY UNIT 7" 11.1 Sub menu All information in this chapter is more information for the healthcare professional. Information on basic operation is contained in the user section. The software of the control and display unit with 7" ' color screen has a sub menu ®...
  • Page 53 ® OmniCycle Connect - User Manual Current section in sub menu Current selection Down/reduce  Move down in direction of arrow.  In menu items where a value is entered (e.g., motor power), the value entered will reduce. Save/confirm changes ...
  • Page 54 ® OmniCycle Connect - User manual 1. Level 2. Level Adjustable values, Factory settings functions Ortho Training time 1-180 min 15 min Biofeedback Symmetry bar Symmetry bar (inactive for upper body Symmetry road Assisted training) Motor power 2-22 Nm 10 Nm (2-8 Nm for upper body exerciser) Muscle support...
  • Page 55 ® OmniCycle Connect - User Manual 1. Level 2. Level Adjustable values, Factory settings functions Virtual cycling Training time 1-180 min 15 min (available as Motor power 2-22 Nm 10 Nm additional (2-8 Nm for upper option) body exerciser) Spasm detection fine medium medium...
  • Page 56 ® OmniCycle Connect - User manual CAUTION! Risk of injury due to inappropriate motor power  Before every training session and every time when changing the training program, check motor power setting. Spasm detection Enables setting the barrier at which the sensor system recognizes an impermissible user's movement and in order to minimize the risk of overstrain, stops the motor.
  • Page 57 ® OmniCycle Connect - User Manual If the user is working at 30 rpm instead of the set number of revolutions (lead Example ® speed) of 15 rpm, the OmniCycle Connect will gradually adjust the lead speed to 25 rpm after approx. 10 seconds. If the user becomes passive again, ®...
  • Page 58: Biofeedback

    ® OmniCycle Connect - User manual Display of operating hours in hours for: Operating hours – Upper body training – Leg exercise – Total Configuration It is possible to set the necessary configuration under menu item Configuration. ❑ The configuration requires an access code and is only to be used by trained suppliers/distributors.
  • Page 59 ® OmniCycle Connect - User Manual ❑ The leg exercise results will be falsified if – the cranks are set to different radii. – then user is not seated in the center. – the leg pushes and pulls. The colors of the biofeedback display can be adjusted in the sub menu by a trained supplier/distributor to accommodate users with red-green blindness (Basic settings/ Configuration).
  • Page 60 ® OmniCycle Connect - User manual Maximum height of bar corresponds to 100% of the power set as motor power. ❑ Value “START” indicates the average power provided by the motor during the first minute of exercise. ❑ The solid part of the bar and the percentage % at the bottom of the bar indicate how many % of the set motor power is required to move the arms or legs.
  • Page 61: Training Report

    ® OmniCycle Connect - User Manual Orange smiley face: ❑ Arms not working together harmonically, or they are moving jerkily. Sleeping smiley face: ❑ Too low or no arm activity. 11.3 Training report NOTE! The activity display may show incorrect values if you pull on the footrests or have set different crank radii.
  • Page 62 ® OmniCycle Connect - User manual The following results are shown: ❑ Training time Total training time without breaks (in minutes). Active ❑ Percentage of the training time, during which the user used his own percentage muscular power (in %). (with muscle power) ❑...
  • Page 63: Motor Power/Joint Force

    ® OmniCycle Connect - User Manual MOTOR POWER/JOINT FORCE 12.1 Motor power for leg exercise CAUTION! Risk of injury due to inappropriate motor power.  Check the configured motor power before every training session and adjust it to the user’s fitness level. ...
  • Page 64 ® OmniCycle Connect - User manual   ❑ = marks of stepless radius adjustment  ❑ = very small radius, for a 2-stepped radius adjustment roughly corresponds to mark 2  ❑ = very large radius, for a 2-stepped radius adjustment roughly corresponds to mark 6 Setting the motor power to fit the user's individual needs: ...
  • Page 65: Motor Power For Upper Body Exercise

    ® OmniCycle Connect - User Manual 12.2 Motor power for upper body exercise The joint forces acting on the user ❑ must be considered in every training session. ❑ increase with reduced radius adjustments and higher motor power settings. The motor power for the upper body exerciser is adjustable between 2 and 8 Nm. Joint forces in kg M (Nm) (1) Position 1 = radius adjustment 6.5 cm (2.6 inches)
  • Page 66: Processing Instructions

    ® OmniCycle Connect - User manual PROCESSING INSTRUCTIONS DANGER! Risk of infection due to contaminated accessories/options!  Wear gloves during cleaning and disinfection. WARNING! Danger to life due to electric shock! Risk of electric shock, fire, or damage to surfaces or materials due to noncompliance with the cleaning and disinfection instructions! ...
  • Page 67 ® OmniCycle Connect - User Manual Preparation before cleaning  Disconnect power cord plug.  check components and safety labels for damage. – If any damage is found, do not clean but contact trained supplier/distributor. Cleaning and disinfection  Clean and disinfect the OmniCycle ®...
  • Page 68: Maintenance And Repairs

    ® OmniCycle Connect - User manual Storage/additional information  Make sure that the clean and disinfected device is stored with a protective cover. Manufacturer contact Follow the instructions of the disinfectant manufacturer, as well as applicable legal provisions. MAINTENANCE AND REPAIRS WARNING! Danger to life due to electric shock! ...
  • Page 69: Troubleshooting

    ® OmniCycle Connect - User Manual TROUBLESHOOTING 15.1 Control and display unit 7'' Error code Troubleshooting ❑Pull power plug and plug it back in after approx. 5 s. Error 16 The OmniCycle ® Connect restarts. If error message occurs repeatedly: ❑Contact trained supplier/distributor.
  • Page 70: General Errors

    ® OmniCycle Connect - User manual 15.3 General Errors Error code Troubleshooting ❑ ® The OmniCycle Reduce crank radius setting. Connect has too little ❑ Increase motor power by one level. power Damage to tendons or joints due to overstraining is possible. ❑...
  • Page 71 ® OmniCycle Connect - User Manual ❑ Voice-controlled Increase microphone sensitivity setting. emergency stop does not respond ❑ Training settings Set and save basic settings again. are incorrect ❑ Reset basic settings to factory settings. ❑ Biofeedback Check if crank radius setting is the same on both sides. symmetry bar or ❑...
  • Page 72: Technical Data

    ® OmniCycle Connect - User manual TECHNICAL DATA ® OmniCycle Connect Dimensions: l x w x h approx. 58-83 cm (22.8 – 32.7 inches) x 47.3 cm (18.6 ❑ leg exerciser inches) x 63 -119 cm (24.8 – 46.85 inches) ❑...
  • Page 73 ® OmniCycle Connect - User Manual ® OmniCycle Connect Suitable for users with ❑ 120 cm (3 feet 11.24 Inches) to 200 cm (6 feet 6.67 Body height inches) ❑ Body weight 180 kg (396.8 lbs.) or120 kg (264.5 lbs.) if footrests with stepless radius adjustment (article no.
  • Page 74: Disposal

    ® OmniCycle Connect - User manual DISPOSAL To dispose of the ® OmniCycle Connect  Observe country-specific regulations and specifications.  Dispose of metal parts as scrap metal.  Dispose of plastic parts according to the type of material.  Dispose of electric and electronic components as electronic scrap. NOTES ON ELECTROMAGNETIC COMPATIBILITY 18.1 Lines, line lengths and accessories ®...
  • Page 75: User Information Acc. To Fcc15.21

    ® OmniCycle Connect - User Manual 18.5 User Information acc. to FCC15.21 Only valid for control and display unit ® 7'' with A006-672 OmniCycle Connect Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 18.6 Statement for Class B digital device acc.
  • Page 76 MANUFACTURER: THERA-Trainer medica Medizintechnik GmbH Blumenweg 8 88454 Hochdorf Germany Tel.: +49 7355-93 14-0 Fax: +49 7355-93 14-15 E-Mail: info@thera-trainer.com Internet: www.thera-trainer.com Art. No.: A009-295_Rev 06 Last update: CW24/2024 For declarations of conformity, see www.thera-trainer.com...

Table of Contents