Idaho Jones TWAIN User Manual

Portable breast pump

Advertisement

Quick Links

Portable Breast Pump
Portable Breast Pump
Soft Silicone
360 Fit Technology
19, 21 and 29mm Attachments Sold Separately
1
User Guide
TWAIN
TWAIN
2x25mm

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TWAIN and is the answer not in the manual?

Questions and answers

Summary of Contents for Idaho Jones TWAIN

  • Page 1 User Guide TWAIN TWAIN Portable Breast Pump Portable Breast Pump Soft Silicone 360 Fit Technology 2x25mm 19, 21 and 29mm Attachments Sold Separately...
  • Page 2: Table Of Contents

    Table of Contents Important Safety Information What’s in the Box Cleaning How to Assemble Pump Motor Instructions How to Pump Finding the Correct Flange Fit Troubleshooting Technical Information Warranty...
  • Page 3 Idaho Jones® Twain Portable Pump INDICATIONS FOR USE The Idaho Jones Twain Portable Breast Pump with Silicone 360 Fit Flange Technology is a suction device intended to express and collect milk from a lactating person’s breasts. It’s one of the few dual breast pumps with completely...
  • Page 4: Important Safety Information

    Important Safety Information Read this user guide carefully before using your breast pump. Save the user guide for future reference. Failure to follow the instructions and safety information included in this guide can lead to danger from the device. • When using any electrical products, basic safety precautions should always be followed.
  • Page 5 Important Safety Information Important Safety Information Important Safety Information (cont’d) Make sure all parts are assembled correctly before pumping. • This product should never be left unattended when plugged in. • Keep the cord away from heated surfaces. • Always unplug electrical product immediately after use. •...
  • Page 6: What's In The Box

    What’s in the Box Shield cap Pump unit 25mm 360 Fit Flange with Bottle stand Integrated duckbill valve Wide neck bottle (4oz) Breast shield Narrow neck bottle Silicon diaphragm connector Diaphragm cap Bottle cap AC adapter Nipple Nipple collar Tubing connector Nipple cap Tubing...
  • Page 7: Cleaning

    Cleaning BEFORE FIRST USE • Disassemble all parts and put the pump motor aside. • Wash all silicone and plastic parts in warm soapy water. • Rinse well with clean water. • Submerge all parts in a pot of water and boil for no longer than 3 minutes.
  • Page 8 Wet or damp parts can cause poor suction. CLEANING THE TUBING • Since the Idaho Jones Twain Pump has a closed system, it is not necessary to clean the tubing. • If you see moisture in the tubes after pumping:...
  • Page 9: How To Assemble

    How to Assemble 1. Assemble the breast shield kit: Insert the soft silicone flange into the breast shield. Ensure the valve is securely attached to the breast shield at the top. Make sure the flange is fully attached to the breast shield Silicone Flange Breast shield...
  • Page 10 How to Assemble (cont’d) 2. Assembling the diaphragm: Press the silicone diaphragm down with your fingers so it’s flush with the top of the breast shield. Place the diaphragm cap on with the hole for the tubing insert positioned slightly to the right. Twist the cap to the left until it’s tightly in place.
  • Page 11 How to Assemble (cont’d) 3. Assembling the bottle and base: Twist the bottle to secure the breast shield kit on to the bottle. Place the bottle on the bottle stand, if using.
  • Page 12 How to Assemble (cont’d) 4. Connecting to the pump: Connect one end of the tubing to the diaphragm cap and the other end to the pump unit. Please make sure that both ends are attached securely. Failure to do so might affect the suction of the pump.
  • Page 13: Pump Motor Instructions

    Pump Motor Instructions Controls Displays Suction Mode Display: Left Side Pumping: Stimulation Mode Indicator Increase Suction Level Button Suction Mode Display: Left Side Pumping: Expression Mode Indicator Reduce Suction Level Button Left Side Pumping: Left Side Pumping: Suction Level Display On/Pause Button Child Lock Display: Press control buttons Alarm Clock Set Up Button...
  • Page 14: How To Pump

    How to Pump Powering the Pump Your Twain Pump can be operated either by using its in-built Lithium Ion battery or by using the provided AC adapter. If using the pump with its battery power: • Make sure that the battery is fully charged before use.
  • Page 15 1-9 using the plus “ ” or minus “ ” buttons. You can press the Left or Right Pumping On/Pause Buttons (or both) to pause pumping and press again to resume. NOTE: Your Twain Breast Pump is designed to turn off automatically after 30 minutes.
  • Page 16 How to Pump (cont’d) Additional Features • Child-Lock: ◦ Activate by pressing left side buttons at the same time. ◦ This feature locks the screen so if you (or your baby!) touches any of the buttons by accident, your pumping setting won’t change. •...
  • Page 17: Finding The Correct Flange Fit

    Finding the Correct Flange Fit Your Twain Breast Pump comes with a 25mm 360 Fit Flange with Integrated Duckbill Valve. Based on your nipple measurement, if you need to size up or down, you can separately purchase the Idaho Jones 360 Fit Flanges in the following...
  • Page 18: Troubleshooting

    Troubleshooting We summarize here the most common issues you can encounter while using your Twain Breast pump. If you are not able to solve the issue with the information below, please email us on hello@idaho-jones.com and we will do everything we can to help you.
  • Page 19 Troubleshooting (cont’d) Issue Solution Condensation or Ensure that the tubing, silicone diaphragm and white cap are dry before use. milk in tubing If condensation occurs, ensure tubing is dry before next use. To do this, disconnect tubing from breast shields and turn the pump back on to dry the tubing while you are storing away your breast milk.
  • Page 20 AC adapter, you might have a defective AC adapter. Please contact Idaho Jones to get a replacement. E3 on screen and Check to see if the pump is over or below the...
  • Page 21: Technical Information

    Technical Information Input 100-240V~ S0/60Hz Power Output 5V ~ 2A Li-ion Battery 3.7V ~ 3600mAh Total Power Stimulation Mode Cycle 60 - 100 cycles/min Speed 30 - 120 mmHg across 9 adjustable Stimulation Mode Vacuum levels Expression Mode Cycle 26 - 60 cycles/min Speed 120 - 247 mmHg across 9 adjustable Expression Mode Vacuum...
  • Page 22: Warranty

    Warranty There is a one-year warranty for the unit from the date of purchase. Proof of purchase in the form order number evidencing that the product is within the warranty period must be presented to obtain warranty. For warranty service, contact hello@idaho-jones.com. This is a single user product.
  • Page 23 SMALL AND MIGHTY PUMP OF DREAMS...

Table of Contents