Advertisement

Quick Links

Titan 290 EHL
SYS-D63-IPC
INSTALLATION, USE AND WARNINGS MANUAL
Edition: 11/2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Titan 290 EHL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Seco Titan 290 EHL

  • Page 1 Titan 290 EHL SYS-D63-IPC INSTALLATION, USE AND WARNINGS MANUAL Edition: 11/2023...
  • Page 2 SYS-D63-IPC PAGE INTENTIONALLY LEFT BLANK Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 3: Table Of Contents

    CHARACTERISTICS AND COMPONENTS OF THE DEVICE ..............16 MEASUREMENT LAYOUT ..............................16 COMPONENTS ..................................17 INSTALLATION ..................................19 PERMITTED ENVIRONMENTAL CONDITIONS ....................19 INSTALLING THE DEVICE ...............................20 VERSIONS AVAILABLE ................................24 MAINTENANCE ..................................26 WASTE DISPOSAL .................................26 Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 4: Preliminary Information

    The SYS-D63-IPC device is a gateway enclosed in a metal box with a heat sink. The technology developed by SECO S.p.A. can be used and applied in various fields. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 5: Recipients

    (if not triggered by the device). The complete warranty terms are set out in the sales contract. IMPORTANT The Manufacturer is not liable for improper use of the device. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 6: Identification

    The device is equipped with an identification plate located on the side. The plate features the device identification information to be reported to SECO S.p.A. if necessary, as shown in the table: Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 7 • Commercial Operating Temperature Range = “C” • Product Revision Index = “x” CAUTION It is strictly forbidden to remove the identification plate and/or replace it with other plates. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 8: Technical Specifications

    Optional on-board M.2 Wi-Fi (802.11 ac / a / b / g / n) +BT 5.0 module, external antennas* Network connection Optional on-board M.2 LTE modem with nanoSIM slot, external antennas* *Certification upon request Dual USB 3.1 Gen1 Type-A connector Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 9 The power supply used must have an output rated ES1 according to IEC 62368-1 Microsoft® Windows 10 Enterprise Microsoft® Windows 10 IoT Core Operating System Linux Yocto Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 10 Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 11: Software Specifications

    • EN 55032:2015+A11:2020 • EN 55035:2017+A11:2020 • EN IEC 63000:2018 • EN 62326:2013 IMPORTANT The Manufacturer is not liable for improper use of the device. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 12: Fcc Disclaimer

    • Consult the dealer or an experienced radio/TV technician for help. IMPORTANT The Manufacturer is not liable for improper use of the device. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 13: Safety Devices

    Do not use liquid detergents or sprays for cleaning the device. CAUTION Do not pour liquids of any kind on the device. This may cause fires and/or electric shocks. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 14 For the mouse, keyboard, USB stick and other peripherals connected to the USB port, the plastic shell must have fire rating of V-0 or higher. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 15: Safety Pictograms Affixed On The Device And Used In The Manual

    Indicates the separate collection of electronic and electrical equipment according to Directive 2012/19/EU. Symbol used to indicate the need to consult the instruction manual before using the equipment. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 16: Characteristics And Components Of The Device

    When running, the device can reach very high temperatures, causing the danger of burns when in contact with the heat sink. Measurement layout Length (A) 180 mm Width (B) 107 mm Height 75 mm Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 17: Components

    “*Predisposition for the installation of the antenna (if present) for the cellular module (telephone). This part is not covered by the IEC 62368-1 certification. **See table in the following page. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 18 SYS-D63-IPC Power supply input IMAGE DESCRIPTION 1 GND (ground) pin 2 +12Vdc pin 12 Pole Bus Connector IMAGE Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 19: Installation

    SECO S.p.A. shall not be held liable if these instructions are not complied with. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 20: Installing The Device

    Proceed to connect the electric supply to the device. Once inserted, turn the connector clockwise in order to lock it in place; Proceed to electrically connect the destination machine. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 21 Once inserted, turn the connector clockwise in order to lock it in place; Proceed to electrically connect the destination machine. SECO S.p.A. shall not be held liable if these instructions are not complied with. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 22 Once inserted, turn the connector clockwise in order to lock it in place; Proceed to electrically connect the destination machine. SECO S.p.A. shall not be held liable if these instructions are not complied with. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 23 If the grounding connection will be used, the customer must have to carried out additional checks to prove compliance for the new installation configuration. SECO S.p.A. shall not be held liable if these instructions are not complied with. Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 24: Versions Available

    SYS-D63-IPC-x6xx-xxxx-Cx (D1) - Comm SYS-D63-IPC-xx0x-xxxx-Cx no eMMC SYS-D63-IPC-xx1x-xxxx-Cx eMMC 16GB Comm. SYS-D63-IPC-xx2x-xxxx-Cx eMMC 32GB Comm. SYS-D63-IPC-xx4x-xxxx-Cx eMMC 64GB Comm. SYS-D63-IPC-xxx1-xxxx-Cx No Module M2 KEY B Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 25 SYS-D63-IPC-xxxx-xx1x-Cx Microsoft® Windows 10 Enterprise (64 bit) on eMMC SYS-D63-IPC-xxxx-xx2x-Cx Linux Yocto (64 bit) on eMMC SYS-D63-IPC-xxxx-xxx1-Cx I/O board protection SYS-D63-IPC-xxxx-xxx2-Cx NO I/O board protection Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 26: Maintenance

    The substances and materials it contains must be disposed of separately in an appropriate manner. The device must be disposed correctly as it is a waste of electric and electronic equipment (WEEE). Information subject to change. Please visit www.seco.com to find the latest version of this manual.
  • Page 27 SYS-D63-IPC PAGE INTENTIONALLY LEFT BLANK Information subject to change. Please visit www.seco.com to find the latest version of this manual.

This manual is also suitable for:

Sys-d63-ipc

Table of Contents