Advertisement

Quick Links

cegard/Smart controller
Installation and Operation Manual
cegard/Smart-CGSM-B
cegard/Smart-CGSM-C
cegard/Smart-CGSM-E
together with EasyGate IP
together with EComgard
RoHS
C
US
CEDES AG is certified according to ISO 9001: 2015
English
Pages
1 – 28
Original version
117 845 | 240718 | V 1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the cegard/Smart-CGSM-B and is the answer not in the manual?

Questions and answers

Summary of Contents for Cedes cegard/Smart-CGSM-B

  • Page 1 Installation and Operation Manual cegard/Smart-CGSM-B cegard/Smart-CGSM-C cegard/Smart-CGSM-E together with EasyGate IP together with EComgard RoHS CEDES AG is certified according to ISO 9001: 2015 English Pages 1 – 28 Original version 117 845 | 240718 | V 1.1...
  • Page 2: Table Of Contents

    15.2 European kits REMARK: In the manual, for the expression transmitter - emitter is used. Receiver edge North America European Union CEDES AG reserves the right to modify or change technical data without prior notice. © CEDES | V 1.1...
  • Page 3: Safety Information

    Any alterations to the device(s) by the buyer, installer or  Consult the safety information in Chapter user may result in unsafe operating conditions. CEDES is 2 of this manual not responsible for any liability or warranty claim that results from such manipulation.
  • Page 4: Introduction

    With the built-in IoT functionality, diagnostic data of the elevator doors and other elevator parameters can be monitored by CEDES Elevate. Consult with your local CEDES representative for details. This document contains the technical specifications of the cegard/Smart controller and its installation procedure.
  • Page 5: Asme A17.1 / Csa B44 Compliance

    If this timer expires before an infringement of the cegard/Smart light curtain (i.e. person or object actually entered the elevator cab), the CabSafe 3D sensor will be rendered inoperative. If the cegard/Smart light curtain © CEDES | V 1.1...
  • Page 6: System Block Diagrams

    • one (1) CabSafe 3D sensor. 1st door 2nd door All other applications must be approved by CEDES. cegard/Smart light curtain Components and accessories not specifically addressed by this document or in the related documents listed in Chapter Figure 2: cegard/Smart 2D system - 1 door 1.2 must be approved by CEDES.
  • Page 7: Cegard/Smart Controller

    Smart Controller itself (other than DIP switch settings). Figure 4: [Bx Variant] cegard/Smart controller with EasyGate IP  Only the CEDES cegard/Smart light curtains and CabSafe 3D sensors can be connected to a cegard/ Smart controller.  Connection cords with a length exceeding 2 m shall be protected in a raceway.
  • Page 8: Mechanical Installation

    5.5.1 Two entrance applications Elevators with two entrances can be supported by a single cegard/Smart controller using an extension module. Different mounting arrangements are possible. Figure 9: cegard/Smart with separate extension module on the car roof surface © CEDES | V 1.1...
  • Page 9: Controller Sensor Configuration

    The cegard/Smart system is configured using twelve (12) DIP switches. The DIP switches are located on the sensor connection PCB as shown in Figure 13 below. For light curtain only (2D) operation, refer to Chapter 6.5. DIP Switches Figure 14: DIP switch location on sensor connection PCB © CEDES | V 1.1...
  • Page 10: Mounting Position

    • If DIP 1 and DIP 2 are both 0 / “OFF”, a configuration American Elevator Safety Code. fault occurs. If DIP 3 and DIP 4 are both 0 / “OFF”, a configuration fault occurs. © CEDES | V 1.1...
  • Page 11 Door position signal from retentive door position switch CEDES offers an optional magnetic reed switch that fulfills this retentive door position switch requirement. In this case, the magnetic reed switch and the actuator must be positioned so that the actuation occurs when the elevator door position (“W”...
  • Page 12: Door Opening Height

    The setting of DIP 9 = 1/”ON” causes that the cegard/ Smart controller to only operate with cegard/Smart light curtain (2D only mode). This functionality requires that the CabSafe 3D sensor be physically disconnected from the cegard/Smart controller, otherwise a configuration fault occurs. © CEDES | V 1.1...
  • Page 13: Output Logic Selector

    DIP 11= 0 DIP 11= 0 DIP 11= 0 Elevator Elevator Elevator DIP 11= 1 DIP 11= 1 DIP 11= 1 Elevator Elevator Elevator Figure 22: DIP 11 settings for multiple elevators positioned face to face © CEDES | V 1.1...
  • Page 14: Reduced Region Of Interest

    CabSafe 3D Timer inactive operative Status CabSafe-3D render inoperative Output to NO contact closed elevator control NC contact closed < 5 s ≥5 s Figure 24: Timing diagram (output logic selection DIP 10 = 0) © CEDES | V 1.1...
  • Page 15: System Installation / Integration

    (3D), install the CabSafe 3D sensor in (for the corresponding holes under the CEDES sticker. flush mounting) or on the back of (back of transom  Attach the interconnect cable between the extension mounting) the elevator transom.
  • Page 16: Startup Cegard/Smart Controller

    2. If not already the case, switch on power to the system. of the corresponding product page at: https://www.cedes. The POWER LED on the cegard/Smart controller will com/en/products-for/elevators-escalators/.
  • Page 17: Troubleshooting

    No error and normal operation. Two options Blinking  3D time out, 5 s timer active (Chapter 7)  Door closed Check error code according to the table next page (Puls error ON or ON or Blinking definition) © CEDES | V 1.1...
  • Page 18: Gateway Pcb Led Status Description

    Pause = 1’800 ms 11.2 Gateway PCB LED status description The Gateway PCB has LED indicators to provide system status. These LEDs are located as shown in Figure 28. LED indicators Figure 28: LED Indicators Gateway Interface PCB © CEDES | V 1.1...
  • Page 19: Maintenance

     3 pulse / Pause: Provisioned but no network connection.  Check connection to sensor connection PCB.  Check connection to extension module.  ON: HW error – Contact CEDES. Hardware replacement may be required.  1 pulse / pause: IoT-HW configuration mismatch on internal SIB PCB.
  • Page 20: Product Label

    The information on the product label includes: ON 1xx xxx Part Number used for ordering PN 1yy yyy Internal CEDES component part number cegard/Smart Controller CGSM-x Description of the cegard/Smart controller variant Manufacturing Date (yymmdd), manufacturing job number (mmmmmmmm), Lot Number...
  • Page 21: European Kits

    7‘ BOT NA 117 929 CGS-SY-B2-22D000 cegard/Smart Two Other cegard/Smart kit configurations are possible. Please CGSM-B2 EU contact your local CEDES representative for additional Light curtain & TOF 3D for front-only or front and rear information. doors: 117 930 CGS-SY-B2-13DBSTFL...
  • Page 22: Accessories

    Switching current 0.5 A, 2.3 mA provided by CabSafe controller at U = 24 VDC Mechanical life (operations) Weight 26 g Technical data - actuator Type BP 11 S Housing material Metal Weight 40 g © CEDES | V 1.1...
  • Page 23: Technical Data

    However, there is no guarantee that interference will not occur in a particular installation. © CEDES | V 1.1...
  • Page 24: Cegard/Smart Extension Module

    Weight 600 g CabSafe 3D sensor 6-pin (J13) WAGO 734-106 (*) Enclosure rating IP43 Gateway RJ-45 (J14) Internal connection to Gateway PCB (J6) or from an extension module to Gateway PCB (J6) * or equivalent © CEDES | V 1.1...
  • Page 25: Communication Interfaces

    18.2 EComgard controller (utilized with cegard/Smart-E variant) CEDES EComgard controller is hardware unit that provides cellular modem communication and ethernet router functionality. It should be located in the machine room or other location where the cellular signal is strong enough to provide consistent connectivity to the IoT Cloud.
  • Page 26 (included with the EComgard controller) for additional details, including LED status information The EComgard switch [LAN 4 connector] is connected and troubleshooting. Please contact your local CEDES to the cegard/Smart controller Gateway PCB [Connector representative if additional EComgard information is J8].
  • Page 27 English 19. Dimensions 19.1 cegard/Smart CGS-B / C / E variants 19.2 Dimensions cegard/Smart extension module 19.3 Dimensions Easygate IP © CEDES | V 1.1...
  • Page 28 English 19.4 Dimensions EComgard © CEDES | V 1.1...
  • Page 29 English © CEDES | V 1.1...
  • Page 30 CEDES AG, Science Park | CH-7302 Landquart Phone: +41 81 307 2323 | info@cedes.com | www.cedes.com...

Table of Contents