  • Page 1 CCS 2 Two-gun fast charger 80KW manual V1.0 T-POWER Pty Ltd. 1 / 23...
  • Page 2: Table Of Contents

    Catalog FOREWORD ..........................4 SAFETY RESPONSIBILITY ACT ......................4 CHAPTER 1 PRODUCT INTRODUCTION ................... 5 DESCRIPTION OF PRODUCTS ......................5 ....................6 OUTWARD APPEARANCE INTRODUCE DESCRIPTION OF MAIN PARAMETERS ....................6 PRODUCT FEATURES ......................... 7 ..................... 8 REGULAR SERVICE CONGDITIONS ..........................
  • Page 3 DAILY MAINTENANCE METHOD OF CHARGER ................22 CHAPTER 6 LETTER OF GUARANTEE ..................... 23 LETTER OF COMMITMENT ....................... 23 WAY OF COMMITMENT ........................23 CHAPTER 7 AFTER-SALES SERVICE AND ORDERING GUIDANCE ............23 AFTER SALES SERVICE ........................23 ORDERING INSTRUCTIONS ......................
  • Page 4: Foreword

    Foreword Thank you for purchasing and using the company's development of chargers products, the company focuses on research and development and provision of new energy electric vehicle charging equipment and solutions, currently has AC chargers, DC chargers, charging operation and management software, such as a complete set of charging system product line, to meet the diverse needs of customers.
  • Page 5: Chapter 1 Product Introduction

    Chapter 1 Product Introduction 1.1 Description of products This product is a 80-120kW with two gun chargers, mainly used in the European standard and daily standard electric vehicle charging. Products with charging protection, swipe charging, scanning, mobile payment, network monitoring, remote upgrade and other functions. This product adopts the principles of industrial design, easy to install, quick to deploy, and has the following innovative design: 1)...
  • Page 6: Outward Appearance Introduce

    1.2 Outward appearance introduce Front view of cabinet 1.3 Description of main parameters detailed product CCS combo 2 description standard Product Two-gun fast charger designation Materiel Galvanized steel body,Acrylic Panel equipment 700*400* 1870 ( L*W*H ) size installation Floor type outward Installation appearance...
  • Page 7: Product Features

    The input 380VAC±20% / L1,L2,L3,N,PE voltage Input 50Hz±10% frequency electrical The power characteristic >0.99 factor <5% CCS2 output 200-1000VDC±5%,(200A) power Applicable Indoors/outdoors scenario Working -30℃ ~ +55℃ temperature Working 5% ~ 95% no condensation humidity Work at an <2000m altitude of Environment target Protection...
  • Page 8: Regular Service Congditions

    low temperature protection, lightning protection, dumping protection, to ensure safe and reliable operation of equipment; Interface-friendly: 7-inch display with real-time display of device status, operating data (voltage, current, ➢ power, charge and time) and fault information 1.5 Regular service condition No more than 2000m above sea level ➢...
  • Page 9: Chapter 2 Operating Instructions

    Chapter 2 Operating Instructions 2.1 Product installation 2.1.1 OUT of box audit After the chargers arrives, open the package and check the following items: ⚫ Exterior inspection: Check whether the chargers is damaged by collision in transit, if there is damage, please notify the carrier immediately.
  • Page 10: Cabinet Installation

    2.1.3 Cabinet installation The embedded parts are suggested as follows: (See installation drawing) The customer needs to pre-reserve the mounting hole by the second size on the mounting table, the equipment is supplied at this size to the good hole, and then with 4 M12 expansion bolts fixed. 2.2 system wiring The system wiring is three-phase, five-wire system, the input line in accordance with the system wiring ➢...
  • Page 11 PE Copper Row Zero-Wire Copper Row AC inline switch(L1、L2、L3 In-line to AC plastic shell circuit breaker) 11 / 23...
  • Page 12: Module Installation

    2.3 Module (charging module) installation After the input line is connected, open the module package, insert the module into the module box, and ➢ set the module address from top to bottom in order. Module installation box Module setup instructions ➢...
  • Page 13 5: After adjusting the address, press the "▽" button for a long time and save it. Power off the module, and power on after the digital tube is not displayed. 6: The default charger is 80kW. If 6 modules are inserted, the PMS needs to be modified ➢...
  • Page 14: Chapter 3 Instructions For The Use Of Chargers

    Module Status LED status Status Description Automatic shutdown protection when the ambient temperature or the internal radiator temperature of Over-temp the module exceeds the set value, and automatic shutdown recovery to the standby state after the temperature is lowered, and it is necessary to issue the power-on command again before starting to work.
  • Page 15 STEP Page instructions The interface is displayed when the charger is idle. Swipe card interface The swiped card interface, where you can see the card number information of the offset card. Click OK to go to the next step Start charging preparation interface 15 / 23...
  • Page 16 Charging information display interface On the charging interface, you can see various information related to the charging process. In the BMS information interface during charging, you can query the relevant information of BMS Home page display interface during charging Manually stop the charging interface. 16 / 23...
  • Page 17 Charging bill display interface Bill home page display interface Continuously click the upper left corner of the display screen to enter the setting page and enter the administrator password interface. initial password is 84726890 Enter the administrator settings interface? # 1 page of administrator setting interface 17 / 23...
  • Page 18 # 2 page of administrator setting interface # 3 page of administrator setting interface # 4 page of administrator setting interface When connecting to the OCPP background, you need to set the network IP address, gateway, stub number, and server IP address on this screen The charging QR code is generated successfully, and the interface is displayed # 5 page of administrator setting interface...
  • Page 19 # 5 page of administrator setting interface Charging information query interface Charging card query interface 19 / 23...
  • Page 20: Chapter 4 Common Failures And Treatment

    Chapter 4 Common Failures and Treatment For all faults, pull Alarm out the gun fault cause information is solution after displayed determining the shutdown Charging gun 1 is 100machine halt connected incorrectly Take gun and start again Charging gun 2 is 101machine halt connected incorrectly Take gun and start again...
  • Page 21: Chapter 5 Charging Machine Maintenance Guide

    gun is too high socket connection is loose BMS sends the command to 400machine halt stop charging If full, it is normal HMI sends the command to 800machine halt stop charging normal X module fault ErrY, X indicates which module is faulty, and Y indicates the fault number Check whether the communication cable of the...
  • Page 22 Current stabilizing accuracy: ≤± 1% ➢ Harmonic current: the total harmonic of input current under load of more than 50% shall not ➢ exceed 10% Efficiency: (full load) ≥ 94%, (more than half load) ≥ 92% ➢ Power factor: ≥ 0.98 ➢...
  • Page 23 safety protection, etc Chapter 6 letter of guarantee 6.1 letter of commitment After receiving the product, the product shall be carefully disassembled to ensure there is no damage and proper visual inspection. If there is any damage due to shipment or other quality problems, report to us in time.

Table of Contents