qunda QD-HVAC10 Installation Manual

qunda QD-HVAC10 Installation Manual

Programmale thermostat

Advertisement

Quick Links

12
~12
Dear client,
Thanks for choosing QD-HVAC10(2S) thermostat
series. It's our best wish to bring you convenience
for your daily life. Before using, please read the
User's Manual carefully. It will help you to use it
correctly.
2.1 Application
Description
Yes
Single Stage Heat and Cool
Multistage Heat and Cool
Yes
Heat Pump without Backup Heat
Yes
Heat Pump with Backup Heat
Yes
Heat Only Systems
Yes
Heat Only Systems-Floor or Wall Furnaces
Yes
Cool Only Systems
Yes
Gas or Oil Heat
Yes
Electric Furnace
Yes
Yes
Millivolt
QD-HVAC10(2S)
2.2 Feature
Programmable thermostat
5+2 Programmable
Easy to program
6.8 square inch display
Battery power or 24V Hardwire
Single Stage Heat and Cool
Multistage Heat and Cool
Heat Pump without Backup Heat
Heat Pump with Backup Heat
No Emergency Heat
Separate heating and cooling swing(cycle
rate) adjustments
5 minutes compressor delay protection
(selectable on or off)
Gas, Electric or Oil
internal temperature sensor or remote sensor
Optional temperature display of Fahrenheit or
Celsius scale.
Low Battery Indicator
Display temperature calibration

Advertisement

loading
Need help?

Need help?

Do you have a question about the QD-HVAC10 and is the answer not in the manual?

Questions and answers

Summary of Contents for qunda QD-HVAC10

  • Page 1 ● (selectable on or off) Dear client, Gas, Electric or Oil ● Thanks for choosing QD-HVAC10(2S) thermostat internal temperature sensor or remote sensor ● series. It's our best wish to bring you convenience Optional temperature display of Fahrenheit or ●...
  • Page 2 Aux+2 symbol: it means the thermostat activates auxiliary heating Cool symbol: The cooling relay start to work when the symbol displayed. QD-HVAC10(2S) The symbol flashing means the cooling relay is in the set-up delay process. Heat symbol: The heating relay start to work when the symbol displayed.
  • Page 4: Terminal Designation

    Wiring-conventinal system: 1 transformer Wiring-conventinal system: 2 transformer Caution: Electrical Hazard Warning : REMOVE JUMPER Failure to disconnect the power All components of the control L1(HOT) L1(HOT) before beginning to install this system and the thermostat product can cause electrical installation must conform to shock or equipment damage.
  • Page 5 Press Default Display(Factory Step Press Buttons Description Defaults) to select parameters SET 5 seconds FA or SL Select fast cooling or slow cooling Select fast heating or slow heating FA or SL Select ℉ or ℃ Readout F or C Compressor Lockout delay time 0 to 5 0~5 minutes...
  • Page 6 01. Select cooling cycle rate 11. internal sensor or remote sensor The FA setting is used to produce shorter cooling cycles. The SL setting produces a longer cooling Users can select a sensor between internal sensor and remote sensor.If you select 0,the system cycle.

This manual is also suitable for:

Qd-hvac10 2s