Page 1
Window Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU 12,000 BTU 14,500 BTU SKU: HME030524N SKU: HME030525N SKU: HME030544N SKU: HME030545N SKU: HME030528N Thank you for purchasing our appliance. Please be sure to read the entirety of this user manual carefully prior to using this appliance.
Manufacturing Info ............. 30 Failure to keep the product in its original quality from the time of receipt may impede hOmeLabs’s ability to correct any legitimate Warning .................. 30 problem and may limit the extent to which hOmeLabs may provide recourse.
Page 3
Congratulations on bringing home your new appliance! Don’t forget to register your product at homelabs.com/reg for updates, coupons, and other relevant information. Although greatly appreciated, product registration is not required to activate any warranty.
important safety instructions • Always install a circuit breaker and a dedicated power circuit. Incorrect installation may cause fire READ THIS MANUAL and electric shock. Read all instructions thoroughly before use and save them for future reference. • Do not operate the unit with wet hands or in a damp environment. It may cause electric shock. Do not direct the airflow at room occupants only.
Page 5
• If water enters the unit, switch off the circuit breaker then unplug the unit from the power outlet. WARNING Isolate the power supply by disconnecting the power plug from the socket, then contact • Do not use other means to accelerate the defrosting process, or other means to clean this unit, a qualified technician.
Page 6
5. Information on Servicing 9) Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and Initial Service should only be performed by a qualified technician. safety checks shall include: 1) Inspect the area Ensuring that capacitors are discharged: this shall be done in a safe manner to avoid possible Before working on systems containing flammable refrigerants, it is necessary to ensure that the sparking;...
Page 7
12. Removal and Evacuation g) Start the recovery machine and operate in accordance with the manufacturer's instructions. When breaking into the refrigerant circuit to make repairs or for any other purpose, conventional h) Do not overfill the cylinders. (No more than 80% volume liquid charge). procedures shall be used.
Installation Instructions PARTS OVERVIEW FCC STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) IMAGE PART QUANTITY this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 9
Installation Instructions Installation Instructions TOOLS NEEDED (NOT SUPPLIED) PRIOR TO INSTALLING THE AIR CONDITIONER 1. Check for anything that could block the airflow. Check the area outside the window for things such as shrubs, trees, or awnings. Check the area inside the window to make sure curtains, drapes, or IMAGE PART blinds will not block proper airflow.
Page 10
Installation Instructions Installation Instructions 2. PREPARE THE AIR CONDITIONER Vinyl-Clad Window The Top Rail must be assembled prior to installing the Air Conditioner in the window. Offset Tools Needed: Phillips Screwdriver Exterior Wall Top Rail Hardware 3/8" Screw Inner Window Sill Top Rail Interior...
Page 11
Installation Instructions Installation Instructions 3. INSTALL THE ACCORDION PANELS 4. INSTALL THE AC UNIT IN THE WINDOW 6. INSTALL THE WEATHER STRIPPING Keep a firm grip on the Air Conditioner, then carefully NOTE: Before driving the screws, drill 5 pilot (ONLY APPLICABLE TO MODELS WITH place the unit into the window opening so the holes (through the holes in the Frame Lock...
Page 12
Celsius (°C) and Fahrenheit (°F). 7. LOCK Refer to the WINDOW AC PAIRING INSTRUCTIONS to pair your AC unit to the hOmeLabs smart app. Press both the °C/°F and TIMER OFF buttons You will need to download the app to your smart phone or a Wi-Fi connected device, such as a tablet.
Operation Operation TIMER SETTING (with the Remote Control) HOW TO USE THE BASIC FUNCTIONS You can set the timer to AUTO-ON, AUTO-OFF, or both. Follow the instructions below to set the timer. POWER ON/OFF Programming Startup Press the POWER button to turn the unit on or off. The unit will activate the Energy Saver function 1.
FRESH AIR VENT CONTROL WEAR AND TEAR NOTE: Only applicable to HME030524N (6K), HME030525N (8K), HME030544N (12K), To minimize wear and tear on the Air Conditioner, always wait at least 3 minutes before changing modes. HME030545N (12K), and HME030528N (14.5K) This will help prevent the compressor from overheating and the circuit breaker from tripping.
Troubleshooting Troubleshooting PROBLEM POSSIBLE CAUSES SOLUTIONS PROBLEM POSSIBLE CAUSES SOLUTIONS • Make sure the power plug is inserted The unit is unplugged Air movement sound • This is normal completely into the outlet The fuse is blown or the circuit •...
These are our general terms for warranty service, but we always urge our customers to reach out to us with any issue, regardless of warranty terms. If you have an issue with a hOmeLabs product, please contact Customer Service at homelabs.com/help or help@homelabs.com.
Page 17
For Household Use Only Distributed by hOmeLabs™, LLC 350 Springfield Avenue, Suite #200, Summit, NJ 07901 help@homelabs.com homelabs.com/help All rights reserved, hOmeLabs™. Made in China.
Need help?
Do you have a question about the HME030524N and is the answer not in the manual?