  • Page 1 (4 L) ULTRA-QUIET Air Compressor Model no. 058-1978-2...
  • Page 2 TABLE OF CONTENTS TECHNICAL SPECIFICATIONS SAFETY GUIDELINES KEY PARTS DIAGRAM KEY PARTS LIST INTENDED USE ASSEMBLY OPERATING INSTRUCTIONS MAINTENANCE TROUBLESHOOTING EXPLODED VIEW PARTS LIST WARRANTY NOTE: If any parts are missing or damaged, or if you have any questions, please call our toll-free helpline at 1-888-670-6682. SAVE THESE INSTRUCTIONS Keep this instruction manual for future use.
  • Page 3 RISK OF BURSTING. Check the maximum pressure rating in the manual or identification label. The compressor outlet pressure must be regulated so that it does not exceed the maximum pressure rating. Relieve all pressure in the hose before removing or attaching accessories.
  • Page 4 058-1983-8 | contact us 1-888-670-6682 model no. 058-1978-2 | contact us 1-888-670-6682 Extension cords RISK OF BURNS. The pump and the check valve generate high temperatures. In order to avoid burns or other injuries, do not touch As the distance from the supply outlet increases, you must use a heavier gauge the pump, the check valve or the transfer tube while the compressor is extension cord.
  • Page 5 058-1978-2 | contact us 1-888-670-6682 A. ELECTRIC MOTOR: The motor is used to power the pump. It is equipped with a thermal overload protector. If the motor overheats for any reason, the thermal PRESSURE overload protector will shut it down in order to prevent the motor from being damaged.
  • Page 6 The procedures described in this manual are solely for this 1 gallon (4 L) air compressor at a maximum pressure of 135 PSI. The device has been designed and constructed for household use only. Compatible compressor and air tool: proper usage and operation Always ensure the use of appropriately-matched air tools with your MAXIMUM Ultra-Quiet Air Compressor.
  • Page 7 058-1978-2 | contact us 1-888-670-6682 onnect air hose to compressor. Assembly • Connect air hose (not provided) to the compressor’s air outlet (H). Unpack the air compressor. Inspect the unit for damage. If the unit has been damaged, contact the retailer immediately.
  • Page 8 058-1978-2 | contact us 1-888-670-6682 Breaking-in the pump 5. Set the pressure switch (C) to the AUTO position. The compressor will start. Run the compressor for 30 minutes. If it falls, turn it off immediately and call the foll-free 1.
  • Page 9 OPEN WARNING! Risk of bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for all CAUTION! tools and accessories. The regulator outlet pressure must never Escaping air and moisture can propel debris that may cause eye exceed the maximum pressure rating.
  • Page 10 058-1978-2 | contact us 1-888-670-6682 To depressurize in emergency. SERVICE ITEM DESCRIPTION/REASON INTERVAL If it is necessary to quickly depressurize the air compressor, turn • the pressure switch (C) OFF. Then, pull on the ring on the safety Through normal operation of your air compressor, valve (D) to quickly release stored air pressure.
  • Page 11 058-1978-2 | contact us 1-888-670-6682 PROBLEM POSSIBLE CAUSES SOLUTIONS PROBLEM POSSIBLE CAUSES SOLUTIONS The power cord is not Plug the power cord into a The regulator or its regulator plugged in. grounded outlet. Replace the regulator. internal parts are dirty or...
  • Page 12 058-1978-2 | contact us 1-888-670-6682 DESCRIPTION QTY. DESCRIPTION QTY. Fan housing Bearing Bolt M5*125 Stator assembly Washer Φ 5 Cable sleeve Washer Φ 4 Bolt M6*10 Hand grip Crank shaft Inlet pipe Bearing Bolt M4*12 Washer Φ 4...
  • Page 13 JOURS J. This warranty will not apply to any product or part thereof if any part from another This MAXIMUM product is guaranteed for a period of manufacturer is installed therein or any repairs or alterations have been made or...
  • Page 14 If you are not completely satisfied with the performance of your MAXIMUM product for any liability or otherwise, exceed, in the aggregate, the amount paid by the purchaser to reason, you can return it within 90 days from the date of purchase with proof of purchase the retailer for the product to which this warranty applies.