  • Page 1 ® ULTRA-QUIET Air Compressor 058-1980-4...
  • Page 2 TABLE OF CONTENTS TECHNICAL SPECIFICATIONS SAFETY GUIDELINES KEY PARTS DIAGRAM KEY PARTS LIST INTENDED USE ASSEMBLY OPERATING INSTRUCTIONS MAINTENANCE TROUBLESHOOTING EXPLODED VIEW PARTS LIST WARRANTY NOTE: If any parts are missing or damaged, or if you have any questions, please call our toll-free helpline at 1-888-670-6682.
  • Page 3 Make sure the regulator is adjusted so that the compressor outlet pressure is set lower than the maximum operating pressure of the spray gun or tool. Before starting the compressor, pull the ring on the safety valve to make sure the valve moves freely (see diagram on page 19).
  • Page 4 058-1980-4 | contact us 1-888-670-6682 Extension cords RISK OF BURNS. The pump and the manifold generate high temperatures. In order to avoid burns or other injuries, do not touch the pump, the manifold or the transfer tube As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power while the compressor is running.
  • Page 5 058-1980-4 | contact us 1-888-670-6682 A. ELECTRIC MOTOR: The motor is used to power the pump. It is equipped with a thermal overload protector. If the motor overheats for any reason, the thermal overload protector will shut it down in order to prevent...
  • Page 6 1.3 HP induction motor for powerful operation. Finishing Nailer (16-gauge) The procedures described in this manual are solely for this 10 gallon (38 L) air compressor at a maximum pressure of 150 PSI. The device has been designed/constructed for household use only.
  • Page 7 058-1980-4 | contact us 1-888-670-6682 4. Connect air hose to compressor. Assembly • Connect air hose (not provided) to the compressor’s air outlet (H). 1. Unpack the air compressor. Inspect the unit for damage. If the unit has been damaged, contact the retailer immediately.
  • Page 8 058-1980-4 | contact us 1-888-670-6682 Breaking-in the pump 5. Set the ON/OFF switch (C) to the ON position. The compressor will start. Run the compressor for 30 1. Set the ON/OFF switch (C) to the OFF position. minutes. If it fails, turn it off immediately and call the toll-free helpline at 1-888-670-6682. Please note that breaking-in the unit is only required prior to first use.
  • Page 9 Risk of bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s Escaping air and moisture can propel debris that may cause eye injury. Wear safety goggles when opening the maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed drain valve.
  • Page 10 058-1980-4 | contact us 1-888-670-6682 To check safety valve SERVICE ITEM DESCRIPTION/REASON INTERVAL Before starting compressor, pull the ring on the safety valve (D) to make sure • Through normal operation of your air compressor, condensation that the safety valve operates freely. If the valve is stuck or does not operate water will accumulate in the tank.
  • Page 11 058-1980-4 | contact us 1-888-670-6682 PROBLEM POSSIBLE CAUSES SOLUTIONS PROBLEM POSSIBLE CAUSES SOLUTIONS The regulator The power cord is not plugged in. Plug the power cord into a grounded outlet. The regulator or its internal parts does not Replace the regulator.
  • Page 12 058-1980-4 | contact us 1-888-670-6682 Description Description Qty. Qty. Air tank Exhaust pipe Solenoid valve Back panel Shock pad Inside buckle handle Power cord Four-way fitting Metal tube Socket Pressure switch Check valve Pressure regulator knob Right panel...
  • Page 13 Quebec, the warranty term will be extended for a period equal to the time during which the MAXIMUM Canada authorised repair centre (“Service Provider”). We will bear the Quebec retailer possesses the product in attempt fulfill warranty obligations; replaced product will not cost of any repair or replacement and any costs of labour relating thereto.
  • Page 14 Neither the retailer, MAXIMUM Canada, nor the manufacturer shall be liable for any other expense, In addition to the 3-Year Limited Warranty, this MAXIMUM product is covered by our: loss or damage, including, without limitation, any indirect, incidental, consequential or exemplary damages arising in connection with the sale, use or inability to use this product.