Page 1
Aurora Server and DM Instruction Manual – Sampling Applications Document 888-0114 Rev A Aurora Server & DM Instruction Manual Sampling Applications Document 888-0114 Revision A Applies to: DM-110e and DM-110h systems...
Page 2
Aurora Solar Technologies Inc. Copyright Information Page Notices The information contained herein is the property of Aurora Solar Technologies Inc., and shall not be disseminated or reproduced in whole or in part without prior written approval of Aurora Solar Technologies Inc. The information herein is subject to change without notice and should not be construed as a commitment by Aurora Solar Technologies Inc.
If the AST supplied AC power cable has to be modified, the work must be performed by a qualified electrician or factory trained technician. Aurora’s products do not contain any user serviceable components and must not be opened for any reason. Doing so will void the warranty. If service is required, please contact AST.
This document provides Installation and Specification information for AST’s measurement and control system consisting of an Aurora Server and a DM measuring head. In addition to the information in this document, the customer should contact and work with an AST Applications Engineer during design and installation.
Central to the system is the Aurora Server which is a common operations and administration controller for the measurement and data collection components on a solar cell production line. The Aurora Server is offered in 1U and 2U rack mount configurations as well as a fanless mini configuration.
Document 888-0114 Rev A 5 Equipment Installation 2U Rack Mount Aurora Server Power off the Aurora Server while locating, mounting and connecting cables Figure 5-1: 2U Rack Mount Aurora Server Ethernet adaptor for DM communication 3 x PCI/PCIe expansion slots for...
The 2U Rack Mount Veritas Server is equipped with two Ethernet adaptors. The left-most adaptor is spare and can be used to connect the Aurora Server to factory networks (i.e. for remote access and support). The right most adaptor is for DM measuring head communication.
5.1.5 Power The 2U Rack Mount Aurora Server accepts a wide range of AC voltages and frequencies. Refer to Section 6.1.1 for more details. It is highly recommended that the AC power connection to the Aurora Server be provided with surge protection. Damage to the equipment due to power surges is not covered by the warranty.
The 1U Rack Mount Veritas Server is equipped with two Ethernet adaptors. The left-most adaptor is spare and can be used to connect the Aurora Server to factory networks (i.e. for remote access and support). The right most adaptor is for DM measuring head communication.
5.2.5 Power The 1U Rack Mount Aurora Server accepts a wide range of AC voltages and frequencies. Refer to Section 6.2.1 for more details. It is highly recommended that the AC power connection to the Aurora Server be provided with surge protection. Damage to the equipment due to power surges is not covered by the warranty.
The Fanless Mini Aurora Server is equipped with two Ethernet adaptors. The left-most adaptor is spare and can be used to connect the Aurora Server to factory networks (i.e. for remote access and support). The right most adaptor is for DM measuring head communication.
5.3.5 Power The DC power supply that is included with each Fanless Mini Aurora Server accepts a wide range of AC voltages and frequencies. Refer to Section 6.3.1 for more details. It is highly recommended that the AC power connection to the Aurora Server’s power supply be provided with surge protection.
Aurora Server and DM Instruction Manual – Sampling Applications Document 888-0114 Rev A Aurora Server communication External trigger input 24VDC power Figure 5-7: DM-110e and DM-110h connectors 5.4.1 Location & Environment Correct location and mounting of the measuring head are critical to satisfactory operation and consultation with an AST Applications Engineer is advised.
5.4.3 External Trigger DM-110e and DM-110h units are each supplied with a 5m trigger cable. As shown in Figure 5-8, one end of the cable is a DSUB-15 and the other end has two flying leads. Figure 5-8: DM external trigger cable...
Aurora Server and DM Instruction Manual – Sampling Applications Document 888-0114 Rev A DM measuring head power is supplied by the DM Power Supply that is included with each system. See Section 5.5 for additional information. DM Power Supply Power off the DM Power Supply while locating, mounting and connecting cables The DM Power Supply is a table top unit that accepts AC power and provides 24 VDC power for a single DM-110e or DM-110h measuring head.
Aurora Server and DM Instruction Manual – Sampling Applications Document 888-0114 Rev A 5.5.1 Location/Mounting The DM Power Supply is to be located within 3m of the DM measuring head that’s being powered. The unit can be placed on any flat surface (desk, etc.) provided it is protected from heat, moisture, vibration, and dust.
Aurora Server and DM Instruction Manual – Sampling Applications Document 888-0114 Rev A 6 Specifications Aurora Server – 2U Rack Mount Computer Configuration 6.1.1 Electrical Specifications Voltage: 100-240 VAC at 50/60 Hz Power: 500 W 6.1.2 Mechanical Specification Dimensions: 482 x 88 x 566 mm Weight: 13.7 kg...
Aurora Server and DM Instruction Manual – Sampling Applications Document 888-0114 Rev A 6.1.5 Support and Field Service Capability The Aurora Server is not field-serviceable. It is replaceable as a complete unit and must not be opened. 6.1.6 Interfaces Specification Monitor –...
6.2.4 Mounting Requirements Table top or 19” rack (1U high) 6.2.5 Support and Field Service Capability The Aurora Server is not field-serviceable. It is replaceable as a complete unit and must not be opened. 6.2.6 Interfaces Specification Monitor - VGA Keyboard/mouse/license dongle –...
Aurora Server and DM Instruction Manual – Sampling Applications Document 888-0114 Rev A 6.3.5 Support and Field Service Capability The Aurora Server is not field-serviceable. It is replaceable as a complete unit and must not be opened. 6.3.6 Interfaces Specification Monitor - HDMI Keyboard/mouse/license dongle –...
Figure 6-4: DM-110e and DM-110h mounting hole pattern The DM-110e and DM-110h measuring heads need to be installed 5mm +/- 0.5mm above wafers. The distance between a wafer and the DM measuring head is defined as the distance between the main DM bottom plate and the top side of wafers.
Document 888-0114 Rev A 6.4.5 Support and Field Service Capability The DM-110e and DM-110h measuring heads are replaceable by the customer as a complete unit. The internal components can only be field serviced by AST authorized personnel. 6.4.6 Interfaces Specification...
Aurora Server and DM Instruction Manual – Sampling Applications Document 888-0114 Rev A 6.5.5 Support and Field Service Capabilities The DM Power Supply is not field-serviceable. It is replaceable as a complete unit and must not be opened. 6.5.6 Interfaces Specification Power to Measurement Head cable –...