Stainless steel flush embalming station (23 pages)
Summary of Contents for MORTECH SS101-ADA
Page 1
All images and Drawing in this manual may not represent your model. Refer to your particular project for exact specifications JANUARY 2022 Mortech™ Manufacturing Inc. ISO Doc. #OM SS-ADA SERIES (REV A) 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
• Is unit draining properly? WARNING • Are all nuts, bolts, and pins secured in place? It is crucial that any work performed on Mortech If unit has an issue contact Mortech Manufacturing. Manufacturing manufactured items are carried out INSTRUCTION FOR HANDLING...
Drawings Step 4. Some stations are large and heavy so it is best to from Mortech for utilities is provided with the submittal packet use a mechanical lift to maneuver the station into position.
Parts listing SS101-ADA Single Scrub Station THERMOSTATICALLY CONTROLLED FAUCET OPERATED BY THERMOSTATICALLY SENSOR SOAP DISPENSER INFRARED SENSOR CONTROLLED FAUCET (SEE ATTACHED LITERATURE) SEE ATTACHED LITERATURE OPERATED BY SENSOR SOAP DISPENSER INFRARED SENSOR (SEE ATTACHED LITERATURE) SEE ATTACHED LITERATURE SENSOR SOAP D (SEE ATTACHED 23.00...
Installation SS101-ADA Single Scrub Station CONNECTION TO EC-3101 CHECK POINT ELECTRIC FAUCET WALL MOUNTED (2) EC-3101 CHECK POINT ELECTRIC FAUCET WALL MOUNTED CONNECT TO DRAIN Mechanical Mixing Valve COLD WATER HOT WATER UTILITY CONNECTION INSTRUCTIONS Personnel working with this unit needs to read this manual.
Page 6
Drawings Step 4. Some stations are large and heavy so it is best to from Mortech for utilities is provided with the submittal packet use a mechanical lift to maneuver the station into position.
Page 7
Parts listing SS102-ADA Double Scrub Station THERMOSTATICALLY CONTROLLED FAUCET OPERATED BY SENSOR SOAP DISPENSER INFRARED SENSOR (SEE ATTACHED LITERATURE) SEE ATTACHED LITERATURE SENSOR SOAP D (SEE ATTACHED SENSOR SO (SEE ATTAC 23.00 16.50 2.50 2.00 REAR FLANGE ALL AROUND 28.00 2.00 REAR FLANGE ALL AROUND 32.00...
Page 8
Installation UTILITY CONNECTION INSTRUCTIONS INSPECTING THE UNIT BEFORE USE STEP 1. Flush out all water lines prior to connection. Debris may be in the lines from construction process. Install shut off • Are all components present? valves on each water line. Lines are clearly marked RED for •...
Page 9
Drawings length provided. from Mortech for utilities is provided with the submittal packet information. Utilities can include: water lines, electrical, etc. Step 4. Some stations are large and heavy so it is best to Some stations are large and heavy so it is best to use a use a mechanical lift to maneuver the station into position.
Page 10
Parts listing SS-103 ADA Triple Scrub Station...
Page 11
Installation UTILITY CONNECTION INSTRUCTIONS INSPECTING THE UNIT BEFORE USE STEP 1. Flush out all water lines prior to connection. Debris may be in the lines from construction process. Install shut off • Are all components present? valves on each water line. Lines are clearly marked RED for •...
Page 12
Installation JANUARY 2018 MFGISO DOC. #OMSS103ADA (REV. A)
The T&S CheckPoint Sensor Operated Faucet is a pre-tem- pered faucet. A mixing valve (supplied) must be used in con- junction with the faucet. Water temperature can be controlled by adjusting the mixing valve. Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 15
Figure 4 SUPPLY APPLICATIONS Wall Mounted-Front View Back View (Supply stops must be furnished by installer or purchased from T&S.) Tighten compression fittings securely on supply lines. Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Power Source: AC and/or DC Do not attempt to open control box. Low Battery Indicator: Red LED on Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Breach of Contract which might arise, is hereby excluded abrasive or chemical cleaners on the sensor lens as this will and disclaimed. Any implied warranties of merchantability damage it and affect operation. Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Continues to Run 1. Debris in solenoid valve, won’t close (Even after power to faucet has been properly. disconnected) 2. Control module is faulty; replace control module. Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 19
• High-capacity output • Compatible with GOJO ® LTX-7™ • Converts to a locking dispenser – 700 ml. refills key included • Lifetime guarantee Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 20
Component Data GOJO LTX-7 DISPENSER DIMENSIONS ™ Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 21
Component Data GOJO LTX-7 REFILL LOADING INSTRUCTIONS ™ Please read all instructions carefully before loading the refill Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Stainless steel equipment maintenance MAINTENANCE INSTRUCTIONS had time to oxidize or decompose. The preferred solvent is one that does not contain chlorine, such as acetone, methyl The unit requires regular maintenance and follow the alcohol, and mineral spirits. manufactures directions. EFFECTIVE CLEANING METHODS DISINFECTING AND CLEANING Commercial Cleaners - Many commercial cleaners...
PARTS AND SERVICE Information in this Manual is subject to change without notice Customer relations and product support are important and does not represent a commitment on the part of Mortech aspects of Mortech Manufacturing. Manufacturing. Mortech Manufacturing assumes no...
Need help?
Do you have a question about the SS101-ADA and is the answer not in the manual?
Questions and answers