Könner & Söhnen KS ATS 4/63D-Inverter Manual

Könner & Söhnen KS ATS 4/63D-Inverter Manual

Automatic transfer switch

Advertisement

Manual
Please, read this manual carefully
before use!
EN
Automatic Transfer Switch (ATS)
KS ATS 4/63D-Inverter

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KS ATS 4/63D-Inverter and is the answer not in the manual?

Questions and answers

Summary of Contents for Könner & Söhnen KS ATS 4/63D-Inverter

  • Page 1 Manual Please, read this manual carefully before use! Automatic Transfer Switch (ATS) KS ATS 4/63D-Inverter...
  • Page 2 INTRODUCTION Thank you for opting for Könner & Söhnen products. This manual contains a brief description of safety, ® setup and use. More information can be found on the official importer’s website in the support section: konner-sohnen.com/manuals You can also go to the support section and download the manual by scanning the QR code or on thewebsite of the official importer of Könner &...
  • Page 3: Specifications

    The total power of power consumers connected to the ATS system must not exceed the maximum permissible PLEASE NOTE! power for this ATS unit model. GENERAL VIEW OF THE ATS UNITS KS ATS 4/63D-INVERTER 1. Preheater 2. Voltmeter 3. Generator power indicator 4.
  • Page 4: Operating Procedure

    Use the control cable to connect the ATS unit to the power generator; the generator must have a special connector PLEASE NOTE! for connecting the ATS. OPERATING PROCEDURE ATS CONNECTOR AND ITS CONNECTION ATS CONNECTOR AND ITS CONNECTION Number Connection function +12V –12V Start relay...
  • Page 5: Wiring Diagrams

    We recommend using three wiring options. The generator must be connected via a 32A 230V CEE socket. The generator must be grounded using either the screw connection or the PE pin in the generator CEE socket. The PE pin (earth) in the generator sockets is connected to the generator housing. The N pin (neutral) in the generator sockets is NOT connected to the generator housing and must be connected to the main earthing busbar as a separate cable at the point of connection of the neutral from the generator on the AVR for the TN power supply system.
  • Page 6: Warranty Provisions

    СONTACT STRIPES WITH WIRING DIAGRAM FOR MODEL СONTACT STRIPES WITH WIRING DIAGRAM FOR MODEL KS ATS 4/63D-INVERTE KS ATS 4/63D-INVERTER R FOR MAINS FOR MAINS Fig. 3 MAIN GRID LOAD GENERATOR MAIN GRID – terminals for the main power supply.
  • Page 7 ANNEX MAIN GRID LOAD GENERATOR konner-sohnen.com |...
  • Page 8 CONTACTS Deutschland: Deutschland: DIMAX International GmbH Flinger Broich 203 -FortunaPark- 40235 Düsseldorf, Deutschland konner-sohnen.com Ihre Bestellungen Ihre Bestellungen orders@dimaxgroup.de Kundendienst, technische Fragen Kundendienst, technische Fragen und Unterstützung und Unterstützung support@dimaxgroup.de Garantie, Reparatur und Service Garantie, Reparatur und Service service@dimaxgroup.de Sonstiges Sonstiges info@dimaxgroup.de Polska:...