Eelectron BO08S01KNX User Manual

Universal module 8 out 20a with current sensors

Advertisement

Quick Links

BO08S01KNX
UNIVERSAL MODULE 8 OUT 20A WITH CURRENT SENSORS
BO08S02KNX
UNIVERSAL MODULE 8 OUT 20A
USER MANUAL
Version: 1.0
Date: 15/Jan/2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BO08S01KNX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eelectron BO08S01KNX

  • Page 1 BO08S01KNX UNIVERSAL MODULE 8 OUT 20A WITH CURRENT SENSORS BO08S02KNX UNIVERSAL MODULE 8 OUT 20A USER MANUAL Version: 1.0 Date: 15/Jan/2024...
  • Page 2: Table Of Contents

    BO08S0xKNX Contents Introduction to the user manual ..............................4 Meaning of the symbols used ..............................4 Product overview ..................................4 Installation instructions ................................4 Configuration and commissioning ............................. 5 General parameters .................................. 5 General settings ..................................5 Voltage configuration ................................5 Global Objects ..................................5 Outputs configuration ................................
  • Page 3 We therefore cannot accept any liability for this. Any necessary corrections will be incorporated into newer ver- sions of this manual. Eelectron S.p.A. Via Claudio Monteverdi 6, I-20025 Legnano (MI), Italia Tel +39 0331.500802 info@eelectron.com BO08S0xKNXFI00020100_UM_EN_1.0 M E M B E R...
  • Page 4: Introduction To The User Manual

    The devices BO08S01KNX and BO08S02KNX are DIN mod- • KNX bus allows you to remotely send commands to the ules with 8 relay outputs of 20A - 230 V AC for controlling lights system actuators.
  • Page 5: Configuration And Commissioning

    (upon request). The value of the 1-bit notification telegram can be set. the ETS® (Engineering Tool Software). For the configuration of the device parameters the corresponding application program or Telegram value off / on / toggle the whole eelectron® product database must be loaded in the Defines the value of the 1 bit notification telegram. The toggle value is ETS® program. not available for “on request” configuration. Period - time unit seconds / minutes / hours The commissioning of the device requires the following steps: Defines the unit of measure of the notification time interval. This pa-...
  • Page 6: Outputs Configuration

    (if enabled) or as command. In BO08S01KNX, the counter function for single re- 7. Outputs configuration lays does not have the “instant power” type available.
  • Page 7: Wrong Application Download

    BO08S0xKNX Behaviour on bus voltage recovery On bus voltage recovery all the communication objects are set to 0 except for objects for which a parameter is defined for the initial value. Wrong application download If the wrong ETS application is downloaded then KNX/EIB led starts blinking and device is not operative on the bus. A pow- er reset must be done or the correct ETS application must be downloaded.

This manual is also suitable for:

Bo08s02knx

Table of Contents