The Manufacturer | 1 The Manufacturer declares that the separator: Liquid Separator (LSS 0100, LSS 0250, LSS 0630) is determined by the serial number: Serial number starts with DEM1… Serial number starts with INM1… Busch Produktions GmbH Busch Manufacturing India Pvt Ltd Schauinslandstr.
Safety Prior to handling the separator, this instruction manual should be read and understood. If anything needs to be clarified, please contact your Busch representative. Read this manual carefully before use and keep for future reference. This instruction manual remains valid as long as the customer does not change anything on the product.
Discharge Connection Nameplate Gas Inlet Glass Cylinder Snap Closure Filter Element (Demister) Baffle Plate Condensate Drain NOTE Illustrations. In this instruction manual, the illustrations may differ from the appearance of the separator. Instruction Manual Liquid Separator LSS 0100-0630_EN_en 5 | 20...
The liquid separator should be connected between the pump and the process at the inlet of the pump. Busch liquid separator is not suitable for overpressure operation and should not be used with aggressive, corrosive, toxic, explosive, or hazardous liquids.
● Transport the liquid separator with adequate load securing only. ● Dispose of packing material in accordance with environmental regulations or reuse it. ● The instruction manual is included in the consignment. Instruction Manual Liquid Separator LSS 0100-0630_EN_en 7 | 20...
● Wrap the separator in a corrosion inhibiting film. ● Store the separator indoors, in a dry and dust free environment and if possible, in original packaging, preferably at temperatures between 5 ... 40 °C. 8 | 20 Instruction Manual Liquid Separator LSS 0100-0630_EN_en...
The liquid separator is intended for the separation of liquids from air, non-aggressive, non-toxic, and non-explosive gases. In case of additional information needed, contact your Busch representative. ● Make sure that the environment of the liquid separator is not potentially explosive.
● Remove all transport plugs before commissioning. ● Make sure that the Installation Conditions are met. ● Switch on the system. ● Due to the function of liquid separator, negative pressure in system is to be expected. 10 | 20 Instruction Manual Liquid Separator LSS 0100-0630_EN_en...
Loss of efficiency! ● Any dismantling of the separator that goes beyond anything that is described in this manual should be done by Busch authorized technicians. ● Make sure of a regular draining of the liquid separator. ● During maintenance work, ensure that the liquid separator is depressurized to atmospheric pres- sure and isolated from the system.
● Check the seals for any damage, replace them if necessary. ● Disclaimer: Intervals must be adapted to specific use case. Delayed maintenance can lead to high- er differential pressure with consequences for the process/vacuum pump. 12 | 20 Instruction Manual Liquid Separator LSS 0100-0630_EN_en...
Maintenance | 8 Maintenance of the Demister ● If the demister cannot be effectively cleaned, it is recommended to replace it to ensure continued efficiency and functionality. * Instruction Manual Liquid Separator LSS 0100-0630_EN_en 13 | 20...
● Check the glass cylinder for any signs of breakage or cracks before starting the operation, replace it if necessary. * ● Use a torque wrench to tighten the top cover nut to 5 Nm. ** 14 | 20 Instruction Manual Liquid Separator LSS 0100-0630_EN_en...
● Decontaminate the separator as much as possible and state the contamination status in a ‘Dec- laration of Contamination’. Busch will only accept separator accompanied by a signed, fully completed and legally binding "dec- laration of contamination", downloadable from the following link: buschvacuum.com/declaration-of- contamination.
● See Storage [➔ 8]. 10.1 Dismantling and Disposal ● Separate special waste from the separator. ● Dispose of special waste in compliance with applicable regulations. ● Dispose of the separator as scrap metal. 16 | 20 Instruction Manual Liquid Separator LSS 0100-0630_EN_en...
CAUTION Hot surface. Risk of burns! ● Before doing anything that requires touching the separator, let it cool down first. For resolution of problems not listed in the troubleshooting table, please contact your Busch repre- sentative. Problem Possible Cause Remedy Not reached usual pressure on The demister is clogged.
Page 20
With a network of over 60 companies in more than 40 countries and agencies worldwide, Busch has a global presence. In every country, highly competent local personnel delivers custom-tailored support backed by a global network of expertise. Wherever you are.
Need help?
Do you have a question about the LSS 0100 and is the answer not in the manual?