Flush lines thoroughly to hook-up When installing the Willoughby Industries’ WAW, WAF, or WWF series When installing the Willoughby Stainless Fountains' WODF-1WM Series drinking fountain system washfountains or lavatory deck systems: or CWBF-1WM Series bottle filler system: Before Step 1 of the installation instructions, ensure that rough-ins are in the correct location�...
Plumbers putty WARNING: Willoughby Stainless Fountains does not assume any responsibility for personal injury or damage to equipment due to an improperly installed WODF-1WM Series drinking fountain system or CWBF-1WM Series bottle filler system: Willoughby Stainless Fountains TOLL FREE (800) 428-4065 ● LOCAL (317) 875-0830 ● FAX (317) 875-0837 Rev.
Wall Mounted- Outdoor Drinking Fountain / Bottle Filler Installation & Operation Manual WODF-1WM Series / CWBF-1WM Series Installation Instructions Step 1: Fixture Installation Note: The WODF outdoor drinking fountain / CWBF outdoor bottle filler is to be mounted on a flat, suitably level surface (wall, concrete or otherwise) with an adequate support structure. Note: Refer to the Physical / Rough-In Dimensions for locating fixture mounting points and plumbing connections. 1�) Install service shut-off valve in water supply line (valve not furnished).
Wall Mounted- Outdoor Drinking Fountain / Bottle Filler Installation & Operation Manual WODF-1WM Series / CWBF-1WM Series Installation Instructions (cont.) Step 2A: Adjusting Drinking Fountain Flow (Push Button) 1�) Insert a standard flat-head screwdriver into adjustment opening on face of pushbutton, as shown�...
Wall Mounted- Outdoor Drinking Fountain / Bottle Filler Installation & Operation Manual WODF-1WM Series / CWBF-1WM Series Care and Maintenance Unit Care Willoughby Stainless Fountains’ WODF Outdoor Drinking Fountains are not freeze resistant. The unit should be disconnected or shut off from the water supply and drained during the colder months.
Wall Mounted- Outdoor Drinking Fountain / Bottle Filler Installation & Operation Manual WODF-1WM Series / CWBF-1WM Series Troubleshooting- Fixture Plumbing I� Insufficient Flow A� Ensure the service shut-off valve is fully open (provided by installer). B� Ensure water supply is within the normal operating range of 40-60 psi�...
Wall Mounted- Outdoor Drinking Fountain / Bottle Filler Installation & Operation Manual WODF-1WM Series / CWBF-1WM Series Troubleshooting - Infrared Sensor I� Bottle filler does not function (red light does not appear when user steps in front of sensor) A� No power to sensor� Make certain that power is on� Check battery power levels, contacts and connections�...
Wall Mounted- Outdoor Drinking Fountain / Bottle Filler Installation & Operation Manual WODF-1WM Series / CWBF-1WM Series Warranty Willoughby Industries, Inc. warrants to commercial and institutional purchasers only that each unit will be free from defects in workmanship and materials under normal use and service upon the following terms and conditions for a period of one (1) year from date of shipment.
Need help?
Do you have a question about the WODF-1WM Series and is the answer not in the manual?
Questions and answers