Information pertaining to the servicing of the torque wrench is contained in the servicing instructions which are available on the Hi-Force website. The right is reserved to make changes at any time without notice.
If in doubt on the correct use of any Hi-Force equipment, contact your nearest Hi-Force office or distributor. Only qualified personnel should be allowed to operate hydraulic equipment/tool.
NEVER attempt to solve, or clean-up leaks in the system while the system is pressurised. • Immediately replace any worn or damaged parts using genuine Hi-Force parts only. • DO NOT use any pneumatic equipment/tools if you are under the influence of alcohol, drugs or medication.
Annex A to this instruction document and is supplied with all shipments of this product. 4.0 Operating Parameters The Hi-Force Pneumatic Torque Wrench is a hand-operated power tool and must be used exclusively for tightening and unscrewing bolted connections. Never combine the wrench with other tools, such as impact screw drivers or drill.
Operating Instruction Manual: Serial Numbers: OM-TWP -01 4.2 Risk Assessment Incorrect use poses the risk of crushing, shearing and serious damage to the torque wrench. Risk of crushing and shearing A jam and shear risk are possible between support arm and abutment (fig. 4.1 & 4.2). The support arm must find a close rest! [Fig 4.2] [Fig 4.1]...
Operating Instruction Manual: Serial Numbers: OM-TWP -01 This leads to a jam risk; the impact socket can burst. Fig 4.5 – correct vs incorrect tool positioning 4.3 Other Hazards A risk of crushing between the pistol-grip and surrounding components. The pistol-grip and /or driving unit can rotate.
Operating Instruction Manual: Serial Numbers: OM-TWP -01 6.2 Component Identification – Air Control Unit Pressure Reduction Valve Air Supply Pressure Gauge Oiler Water Trap Hose Air Control Unit Complete Fig 6.1 – Air Control Unit...
Operating Instruction Manual: Serial Numbers: OM-TWP -01 7.0 Installation / Setup 7.1 Before First Use / Preparation Immediately after unpacking, examine the unit for signs of transit damage and if found contact the shipping company. 7.2 Technical Data Consumption of compressed air: 20 l/s at 6.3 bar Nominal capacity: 0.85 KW...
The wrench should only be operated using the air control unit (12) with water trap (11), oiler (14) and hose (15) from Hi-Force, this is necessary to guarantee the precision of the torque values. The precision of the torque values is only guaranteed if the torque wrench is used with the original Hi- Force air control unit.
Use only genuine Hi-Force accessories and genuine Hi-Force spare parts. Hi-Force is not responsible for any personal injury or machine damage that occur due to the use of non- genuine Hi-Force accessories and spare parts or repairs carried out by unauthorized service workshops.
Page 13
Operating Instruction Manual: Serial Numbers: OM-TWP -01 Head Office: Hi-Force Limited Prospect Way, Daventry Northamptonshire NN11 8PL United Kingdom Tel: + 44 1327 301000 | Fax: + 44 1327 706555 www.hi-force.com Regional Offices: For information on our offices worldwide, scan the below QR code...