Selection Of Installation Place; Power Source - Haier HSU-09C12 Installation Manual

User manual
Hide thumbs Also See for HSU-09C12:
Table of Contents

Advertisement

Available languages

Available languages

140
415
140
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-09C12
HSU-12C12
HSU-09C13
HSU-12C13
HSU-09C03/Z1
HSU-12C03/Z1
Fixing of outdoor unit
Indoor Unit
Place, robust not causing vibration, where the body can be supported
sufficiently.
Place, not affected by heat or steam generated in the vicinity, where
inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the
outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer
to drawings).
Place where the distance of more than lm from televisions, radios,
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
140
500
140
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-18C13
HSU-18CK03
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally.
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Selection of Installation Place

Power Source

Selection of pipe
Gas pipe(
Gas pipe(
2
583
113.5
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-22C13
HSU-24C13
Place, which is less affected by rain or direct sunlight and is
sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are
not increased.
Place, where discharged wind and noise do not cause a
nuisance to the neighbors.
Place, where a distance marked
in the above figure.
For 09
For 12,18
)
6.35mm(1/4")
6.35mm(1/4")
)
9.52mm(3/8")
12.7mm(1/2")
113.5
Outdoor Unit
is available as illustrated
For 22 24
9.52mm(3/8")
15.88mm(5/8")