    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-07RA03/R1(B) HSU-09RA03/R1(B) HSU-12RA03/R1(B) H2SM-18RA03/R1(B) Please read this operation manual before using the air conditioner.
  • Page 2 Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe. Unplug the air conditioner ully.
  • Page 3 3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. 4. The wiring method should be in line with the local wiring standard.
  • Page 4: Safety Instruction

    Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place CAUTION Do not install in the...
  • Page 5 PROHIBITION PROHIBITION CAUTION Take fresh air occasionally especially Do not operate the switch with Do not use for the purpose of storage of food, art work, precise equipment, when gas appliance is running at the wet hand. breeding, or cultivation.
  • Page 6: Parts And Functions

    (Use remote controller to adjust up and down air flow. Don't adjust it manually) Horizontal louver (adjust left and right air flow) Power plug For multi-split type, the power plug is on the outdoor unit. Outdoor unit HSU-07RA03/R1(B) H2SM-18RA03/R1(B) HSU-09RA03/R1(B) HSU-12RA03/R1(B)
  • Page 7 B will be displayed on LCD. 9. SLEEP display Please select A without special explanation. 10. SWING UP/DOWN display NOTE: (1)The following functions and related displays are not available (2) Cooling only unit do not have functions and displays related with heating.
  • Page 8 If the remote controller can't run normally during operation, please remove the batteries reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any disp taking-out, just need to press reset key.
  • Page 9: Health Operation

    Note When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.
  • Page 10: Auto Operation

    1. Unit start Link with electronic power. Remote controller Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow). 2.Select operation mode Press MODE button. For each press, operation mode...
  • Page 11: Cool Operation

    1. Unit start Link with electronic power. Remote controller Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow). 2.Select operation mode Press MODE button. For each press, operation mode...
  • Page 12: Dry Operation

    LOW speed regardless of FAN setting. T e m p . s e t t i n g + 2 T e m p . s e t t i n g 5.Unit stop Press ON/OFF button, the unit stops.
  • Page 13: Fan Operation

    Press ON/OFF button, the unit stops. About FAN operation In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
  • Page 14: Heat Operation

    Remote controller: AUTO Air conditioner is running under displayed wind speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 15: Air Flow Direction Adjustment

    When making coolness, wind orientation should adjust to the horizontal state in favor of air circulating in the room for cool air will agglomerate upside. When making heat, wind orientation should adjust to the slanting down state...
  • Page 16: Sleep Operation

    Note The sleeping hours lasts 8 hours and couldn't be adjusted. When timing on function is set, the sleeping function can't be set up After the sleeping function is set up, if user resets timing on function, the sleeping function will be cancelled; the machine will be in the state of timing-on.
  • Page 17: Timer On/Off Operation

    Hints: After replacing batteries or a power failure happens, time setting should be re Remote controller possesses memory function, when use TIMER mode next time,just press SET button after mode selecting if time setting is the same as previous o...
  • Page 18 " on the remote controller stops flashing. " " starts flashing. Time displayed: Unit starts or stops at x hour x min. 5.Time setting for TIMER OFF Just press HOUR button ,follow the same procedure in "Time setting for TIMER ON"...
  • Page 19: Power/Soft Operation

    To cancel POWER operation Press POWER/SOFT button twice ,POWER/SOFT disappears. SOFT Operation You can use this function when silence is needed for rest or read Selecting of SOFT operation Press POWER/SOFT button. Every time the button is pressed,display changes as follows:...
  • Page 20: Health Airflow Operation

    2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air condi are closed and the airflow is blown vertically from the nether inlet and outlet grills. Avoid the strong airflow blows direct the body.
  • Page 21: Emergency And Test Operation

    In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature. When machine is running in emergency, the set value of temperature and wind speed couldn't be altered; meanwhile, it can't operate for dehumidifying or under timing mode.
  • Page 22: Maintenance

    Use the timer effectively during operation During cooling operation, prevent the penetration of direct sunlight with curtain or blind. Use the louvers effectively If the unit is not to be used for a long time, turn off the power supply main switch.
  • Page 23: Air Filter Cleaning

    Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance,be sure to turn off the system and the circuit breaker. Remote Controller Indoor Body Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral Do not use water, wipe the controller with a detergent diluted with water.Wring the water...
  • Page 24: Replacement Of Air Purifying Filter

    The bacteria-killing medium air purifying filter is available for a long time and needn't to be changed. But it must be noticed to use the vacuum cleaner frequently to adsorb the dusts covering the purifying filter lest the covering dusts effect t function of the bacteria-killing medium air purifying filter.
  • Page 25 To Keep Your Air conditioner in Good Condition after Season. Operate in cooling mode for 2-3 hours. To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30 C,cooling mode and High speed fan mode for 2-3 hours.
  • Page 26: Connecting The Earthing Cable

    Before Setting in High season Cleaning the standard air filter. Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes. Connecting the earthing cable. Caution Incomplete earthing may cause an electric shock.
  • Page 27: Troubleshooting

    This noise is generated by the casing expanding or shrinking because of inspection temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated.