  • Page 1 AXIS C6110 Network Paging Console User manual...
  • Page 2: Table Of Contents

    Connect external equipment ........Use an AXIS TC6901 Gooseneck Microphone ......
  • Page 3: Installation

    Installation Installation The following video shows an example of how you can install an AXIS C6110 Network Paging Console together with an AXIS TC6901 Gooseneck Microphone. For complete instructions on all installation scenarios as well as important safety information, see the installation guide on axis.com/products/axis-c6110/support.
  • Page 4: Get Started

    Get started Find the device on the network To find Axis devices on the network and assign them IP addresses in Windows®, use AXIS IP Utility or AXIS Device Manager. Both applications are free and can be downloaded from axis.com/support.
  • Page 5: Secure Passwords

    Verify that no one has tampered with the device software To make sure that the device has its original AXIS OS, or to take full control of the device after a security attack: 1. Reset to factory default settings. See Reset to factory default settings on page 50.
  • Page 6: Configure Your Device

    AXIS C6110 Network Paging Console Configure your device Configure your device Set up direct SIP (P2P) Use peer-to-peer when the communication is between a few user agents within the same IP network and there is no need for extra features that a PBX-server could provide. To better understand how P2P works, see Peer-to-peer SIP (P2PSIP) on page 14.
  • Page 7: Add Contacts And Recipient Devices

    Note Only contacts that are persons will appear in the contacts list on the display of your AXIS C6110 Paging Console. Devices will not show up in the contacts list, but you can configure a button on the display to target the device directly.
  • Page 8: Configure Buttons, Folders And Pages

    AXIS C6110 Network Paging Console Configure your device 1. Go to Contact list > Groups. 2. Click Add contact group and enter the details. For information about the options, see Contact list on page 17. 3. Click Save. Configure buttons, folders and pages To configure buttons and folders, open the web interface by entering the IP address of your paging console in a web browser.
  • Page 9 AXIS C6110 Network Paging Console Configure your device To learn more, check out our guide Get started with rules for events.
  • Page 10: Place And Receive A Call

    AXIS C6110 Network Paging Console Place and receive a call Place and receive a call Place a call 1. Navigate to the page on the display where the contact is located. Contacts are indicated by 2. To place a call, press the button for the contact.
  • Page 11: Page A Message

    AXIS C6110 Network Paging Console Page a message Page a message To page a one-way live callout: 1. Navigate to the page on the display where the target is located. The target can be an individual person or device, or a group. Targets are indicated by 2.
  • Page 12: Play An Announcement

    AXIS C6110 Network Paging Console Play an announcement Play an announcement Play a pre-recorded audio file: 1. Navigate to the page on the display where the announcement is located. Announcements are indicated by 2. Press the button for the announcement.
  • Page 13: Connect External Equipment

    3. Set Input type to Balanced microphone. Use a headset You can connect a headset to the 3.5 mm audio connector located on the side of the AXIS C6110 Network Paging Console. You can adjust the volume for the headset using the volume buttons.
  • Page 14: Learn More

    The Session Initiation Protocol (SIP) is used to set up, maintain and terminate VoIP calls. You can make calls between two or more parties, called SIP user agents. To make a SIP call you can use, for example, SIP phones, softphones or SIP-enabled Axis devices.
  • Page 15: Nat Traversal

    NAT traversal Use NAT (Network Address Translation) traversal when the Axis device is located on an private network (LAN) and you want to access it from outside of that network. Note The router must support NAT traversal and UPnP®.
  • Page 16: The Web Interface

    Device info Shows the device information, including AXIS OS version and serial number. Upgrade AXIS OS: Upgrade the software on your device. Takes you to the Maintenance page where you can do the upgrade. Time sync status Shows NTP synchronization information, including if the device is in sync with an NTP server and the time remaining until...
  • Page 17: Communication

    Shows what kind of access to the device that is active, what encryption protocols are in use, and if unsigned apps are allowed. Recommendations to the settings are based on the AXIS OS Hardening Guide. Hardening guide: Link to AXIS OS Hardening guide where you can learn more about cybersecurity on Axis devices and best practices.
  • Page 18 AXIS C6110 Network Paging Console The web interface For paging a group of Axis devices using VAPIX. Add group: Click to create a new group of existing contacts. • Name: Enter a name for the group. • VAPIX contacts: Select the VAPIX contacts you want to include in the group. The list include contacts that you have created on the Contacts tab.
  • Page 19 AXIS C6110 Network Paging Console The web interface • TURN: TURN (Traversal Using Relays around NAT) is a protocol that lets a device behind a NAT router or firewall receive incoming data from other hosts over TCP or UDP. Enter the TURN server address and the login information.
  • Page 20 AXIS C6110 Network Paging Console The web interface • Caller ID: The name which is presented to the recipient of calls from the device. • Registrar: Enter the IP address for the registrar. • Transport mode: Select the SIP transport mode for the account: UPD, TCP, or TLS.
  • Page 21: Display

    AXIS C6110 Network Paging Console The web interface Use access list: Turn on to restrict who can make calls to the device. Policy: • Allow: Select to allow incoming calls only from the sources in the access list. • Block: Select to block incoming calls from the sources in the access list.
  • Page 22: Audio

    AXIS C6110 Network Paging Console The web interface Actions + Add action: Click to create an action that can be used for the buttons. Available action types: • Announcement: Select to make an announcement (play an audio file to a person or a device).
  • Page 23 AXIS C6110 Network Paging Console The web interface Input type : Select the type of input, for instance, if it’s internal microphone or line. Power type : Select power type for your input. Apply changes : Apply your selection. Echo cancellation : Turn on to remove echoes during two-way communication.
  • Page 24: Recordings

    AXIS C6110 Network Paging Console The web interface Listen and record Click to listen. Start a continuous recording of the live audio stream. Click again to stop the recording. If a recording is ongoing, it will resume automatically after a reboot.
  • Page 25: Apps

    • Activate license with a key: If the app requires a license, you need to activate it. Use this option if your device doesn’t have internet access. If you don’t have a license key, go to axis.com/products/analytics. You need a license code and the Axis product serial number to generate a license key.
  • Page 26 AXIS C6110 Network Paging Console The web interface The time format depends on the web browser’s language settings. Note We recommend you synchronize the device’s date and time with an NTP server. Synchronization: Select an option for the device’s date and time synchronization.
  • Page 27 AXIS C6110 Network Paging Console The web interface Assign IPv4 automatically: Select to let the network router assign an IP address to the device automatically. We recommend automatic IP (DHCP) for most networks. IP address: Enter a unique IP address for the device. Static IP addresses can be assigned at random within isolated networks, provided that each address is unique.
  • Page 28 One-click cloud connection One-click cloud connection (O3C) together with an O3C service provides easy and secure internet access to live and recorded video from any location. For more information, see axis.com/end-to-end-solutions/hosted-services. Allow O3C: • One-click: This is the default setting. Press and hold the control button on the device to connect to an O3C service over the internet.
  • Page 29 Authentication failed: Sends a trap message when an authentication attempt fails. Note All Axis Video MIB traps are enabled when you turn on SNMP v1 and v2c traps. For more information, see AXIS OS Portal > SNMP. • v3: SNMP v3 is a more secure version, which provides encryption and secure passwords. To use SNMP v3, we recommend you to activate HTTPS, as the password is then sent through HTTPS.
  • Page 30 When configured without a CA certificate, server certificate validation is disabled and the device tries to authenticate itself regardless of what network it is connected to. When using a certificate, in Axis' implementation, the device and the authentication server authenticate themselves with digital certificates using EAP-TLS (Extensible Authentication Protocol - Transport Layer Security).
  • Page 31 AXIS C6110 Network Paging Console The web interface • Peap version: Select the Peap version that is used in the network switch. • Label: Select 1 to use client EAP encryption; select 2 to use client PEAP encryption. Select the Label that the network switch uses when using Peap version 1.
  • Page 32 To install test software or other custom software from Axis on the device, you need a custom signed AXIS OS certificate. The certificate verifies that the software is approved by both the device owner and Axis. The software can only run on a specific device which is identified by its unique serial number and chip ID.
  • Page 33 AXIS C6110 Network Paging Console The web interface Add SSH account: Click to add a new SSH account. • Restrict root access: Turn on to restrict functionality that requires root access. • Enable SSH: Turn on to use SSH service.
  • Page 34 AXIS C6110 Network Paging Console The web interface Add a rule: Create a rule. Name: Enter a name for the rule. Wait between actions: Enter the minimum time (hh:mm:ss) that must pass between rule activations. It is useful if the rule is activated by, for example, day-night mode conditions, to avoid that small light changes during sunrise and sunset activate the rule repeatedly.
  • Page 35 The SFTP client supports SFTP servers using SSH-2 with RSA, DSA, ECDSA, and ED25519 host key types. RSA is the preferred method during negotiation, followed by ECDSA, ED25519, and DSA. Make sure to enter the right MD5 host key that is used by your SFTP server. While the Axis device supports both...
  • Page 36 RSA is the preferred method during negotiation, followed by ECDSA, ED25519, and DSA. Make sure to enter the right MD5 host key that is used by your SFTP server. While the Axis device supports both MD5 and SHA-256 hash keys, we recommend using SHA-256 due to stronger security over MD5. For more information on how to configure an SFTP server with an Axis device, go to the AXIS OS Portal.
  • Page 37 IoT integration and is used in a wide variety of industries to connect remote devices with a small code footprint and minimal network bandwidth. The MQTT client in Axis device software can simplify integration of data and events produced in the device to systems which are not video management software (VMS).
  • Page 38 AXIS C6110 Network Paging Console The web interface Device topic prefix: Used in the default values for the topic in the connect message and LWT message on the MQTT client tab, and in the publication conditions on the MQTT publication tab.
  • Page 39 DNS. Windows SMB/CIFS names are not supported. • Network share: Enter the name of the shared location on the host server. Several Axis devices can use the same network share since each device gets its own folder.
  • Page 40 When you create an ONVIF account, you automatically enable ONVIF communication. Use the account name and password for all ONVIF communication with the device. For more information see the Axis Developer Community at axis.com.
  • Page 41 AXIS C6110 Network Paging Console The web interface Add accounts: Click to add a new ONVIF account. Account: Enter a unique account name. New password: Enter a password for the account. Passwords must be 1 to 64 characters long. Only ASCII printable characters (code 32 to 126) are allowed in the password, for example, letters, numbers, punctuation, and some symbols.
  • Page 42 AXIS C6110 Network Paging Console The web interface • Select configuration: Select a user-defined configuration from the list and adjust the settings. The configurations in the drop-down list act as identifiers/names of the configuration. Audio output : Select the audio output format for your configuration.
  • Page 43 AXIS C6110 Network Paging Console The web interface Port Name: Edit the text to rename the port. Direction: indicates that the port is an input port. indicates that it’s an output port. If the port is configurable, you can click the icons to change between input and output.
  • Page 44: Maintenance

    AXIS OS upgrade: Upgrade to a new AXIS OS version. New releases can contain improved functionality, bug fixes, and completely new features. We recommend you to always use the latest AXIS OS release. To download the latest release, go to axis.com/support.
  • Page 45 AXIS OS version after the upgrade. • Autorollback: Upgrade and confirm the upgrade within the set time. If you don’t confirm, the device reverts to the previous AXIS OS version. AXIS OS rollback: Revert to the previously installed AXIS OS version.
  • Page 46: Specifications

    AXIS C6110 Network Paging Console Specifications Specifications Product overview Security slot Headset connector (3.5 mm audio connector) See Audio connector on page 47 Volume buttons Push-to-talk button Soft keys SD card slot on page 47 USB connector (not in use)
  • Page 47: Sd Card Slot

    The device shall be connected using a shielded network cable (STP). All cables connecting the device to the network shall be intended for their specific use. Make sure that the network devices are installed in accordance with the manufacturer’s instructions. For information about regulatory requirements, see the Installation Guide at www.axis.com. Audio connector 3.5 mm input/output connector for headset (4-pole TRRS) or headphone (3-pole TRS).
  • Page 48 Micro- Channel 1, unbalanced line Channel 2, unbalanced line Ground phone XLR connector For more information, see Use an AXIS TC6901 Gooseneck Microphone on page 13 Function Ground Balanced Microphone Hot (+) In Balanced Microphone Cold (-) In I/O connector Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm notifications.
  • Page 49 AXIS C6110 Network Paging Console Specifications DC ground DC output 12 V, max 50 mA Digital I/O Digital I/O Configurable I/O (RS485) Configurable I/O (RS485)
  • Page 50: Reset To Factory Default Settings

    5. Use the installation and management software tools, assign an IP address, set the password, and access the product. You can also reset parameters to factory default through the device’s web interface. Go to Maintenance > Factory default and click Default. Contact support If you need more help, go to axis.com/support.
  • Page 51 User manual Ver. M1.22 AXIS C6110 Network Paging Console Date: June 2024 © Axis Communications AB, 2024 Part no. T10201145...