honle EVG UVT 16-25W 400mA Operating Manual

Electronic power supply with wide range power supply 85 – 264 vac

Advertisement

Quick Links

uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410
Operating Manual
Electronic Power Supply
with wide range power supply 85 – 264 VAC
Stand: 15.08.2017
EVG UVT 16-25W 400mA
EVG UVT 20WHO 670mA
EVG UVT 30WHO 700mA
EVG UVT 40W 425mA
EVG UVT 2x 40W 425mA
EVG UVT 40WHO 800mA
EVG UVT 55WHO 540mA
EVG UVT 75W 425mA
EVG UVT 75WHO 800mA
EVG UVT 80WHO 800mA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVG UVT 16-25W 400mA and is the answer not in the manual?

Questions and answers

Summary of Contents for honle EVG UVT 16-25W 400mA

  • Page 1 International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Operating Manual Electronic Power Supply with wide range power supply 85 – 264 VAC EVG UVT 16-25W 400mA EVG UVT 20WHO 670mA EVG UVT 30WHO 700mA EVG UVT 40W 425mA EVG UVT 2x 40W 425mA...
  • Page 2 uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Imprint All rights reserved uv-technik international ©Copyright by Printed in Germany, 15 August 2017 No parts of this operating manual may be reproduced in any form without the prior written permission of UV-Technik international.
  • Page 3: Table Of Contents

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Table of contents Warning notes and symbols in the operating instructions ............4 Device and function description ................... 5 Safety instructions ....................... 6 General information ............................6 Appropriate use ............................. 6 Staff obligation ..............................
  • Page 4: Warning Notes And Symbols In The Operating Instructions

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Warning notes and symbols symbols in the operating instructions These operating instructions describe the nstructions describe the singled flamed electronic power supply of the of the wide range EVG UVT series, its operation and its uses. The safety and warning notices explain the safe, proper s, its operation and its uses.
  • Page 5: Device And Function Description

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Device and function description The EVG UVT with wide range power supply is an electronic ballast for UV low-pressure lamps and is suitable for all 50/60 Hz mains voltages worldwide. The single or two-flame units are available in the same size for lamp outputs of 16 ...
  • Page 6: Safety Instructions

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Safety instructions General information A sound knowledge of all basic safety regulations is essential A sound knowledge of all basic safety regulations is essential to ensure safe and fault to ensure safe and fault-free operation of the EVG UVT.
  • Page 7: Warranty And Liability

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Warranty and liability UV-Technik international applyly. The operator will have The General sales and delivery conditions of sales and delivery conditions of received these terms, at the latest upon signing the contract received these terms, at the latest upon signing the contract.
  • Page 8: Transport, Storage, Delivery

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 WARNING! Without the permission of UV-Technik international, no alterations, modifications as well as repairs to the EVG UVT may be carried out. Opening the device or breaking of the existing device inspection seals will void all warranty claims! Transport, storage, delivery The EVG UVT will be delivered in an appropriate packing.
  • Page 9: Failure Table

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Failure table fault fault description, possible cause measures ignition problem lamp fault (e.g. leaky lamp) replace lamp filaments of the lamps do not glow/preheat wrong lamp, connect correct lamp connection fault /loose connection check cabling, clamps ignition voltage drop above the cable too high shorten lamp cable, enlarge cross section...
  • Page 10: Installation

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Installation instructions designed for installation in electrical cabinets IP protection code IP20 size of housing 230 x 40 x 30 mm (L x B x H) mounting position arbitrary ambient temperature = 0…50°C relative humidity max.
  • Page 11: Dimensional Drawings

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Dimensional drawings Connection plan Lampe / lamp Lampe / lamp Kontakt Kontakt Contact Contact Lampe / lamp Lampe / lamp Kontakt Kontakt Contact Contact Lampe / lamp Lampe / lamp Kontakt Kontakt Contact Contact...
  • Page 12: Hints For Installation

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Hints for installation Point of installation The EVG UVT may only be installed and operated in a dry, chemically and biologically inactive environment. The assembly must not be carried out in vibrating parts. Information on IP protection must be observed. The EVG UVT must be properly grounded.
  • Page 13: Grounding

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 Grounding A clean earth potential and a proper grounding with an adequate cable cross section are the preconditions for compliance with the EMC standards. Only if this is guaranteed, high frequecy disturbances can be derived an thus prevented.
  • Page 14: Monitoring

    uv-technik International • www.uv-technik.co.uk • Phone +44 (0)1582 805410 operating currents, but also by the impact load. If possible, use slow-blow fuses. The same applies to the ground fault circuit interrupter (GFCI), which is triggered either by the high temporary inrush current or a low continuous current.