OPERATING INSTRUCTIONS MANUAL
ENGLISH
PICASSO LITE+ | PICASSO+

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PICASSO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AMD Lasers PICASSO

  • Page 1 OPERATING INSTRUCTIONS MANUAL ENGLISH PICASSO LITE+ | PICASSO+...
  • Page 2 Type B Applied Part to Medical Equipment Disposal. Laser Danger Warning Label xxx ˚C Do Not Autoclave Class II Equipment PICASSO LITE+ | PICASSO+ Single Use Only Must Read Manual Prior to Use OPERATING Consult Instruction For Use Battery Symbol with Polarity INSTRUCTIONS...
  • Page 3: Table Of Contents

    IC: RSS-GEN ........................... 9 Transportation ..........................32 Contents of Picasso+ and Picasso Lite+ ..................10 Footswitch Battery Replacement ....................32 Main Units: Picasso+ | Picasso Lite+ —Figure 1 ................11 Environmental Protection ....................... 32 Indications For Use ........................... 12 Calibration Procedure ........................33 Laser Periodontal Procedures ......................
  • Page 4: Introduction

    WARNING: To avoid eye or skin exposure to direct or scattered radiation, do not use the Picasso Plus The Picasso® line of soft tissue dental lasers is designed for a wide variety of oral soft tissue and teeth or Picasso lite Plus without the appropriate tip for the procedure being performed.
  • Page 5: Safety Features

    Removal is accomplished by sliding the portion of the connector closest to the laser housing away from • Operation Mode: See Specifications the laser. Remote Interlock not included. To utilize this feature of the Picasso laser please reach out to customer service and other third-party providers.
  • Page 6: Ic: Rss-Gen

    [1] this device may not cause interference, and [2] this device must accept any interference, including Wireless Foot Control Wireless Foot Control Standard Picasso+ and Picasso Lite+ interference that may cause undesired operation of the device. | Operating Instructions Manual...
  • Page 7: Main Units: Picasso+ | Picasso Lite+ -Figure 1

    MAIN UNITS: PICASSO+ | PICASSO LITE+ —FIGURE 1 INDICATIONS FOR USE Use of Picasso Plus and Picasso Lite Plus is generally indicated for incision, excision, vaporization, ablation and coagulation of oral soft tissues including the following: • Gingival troughing for crown impression •...
  • Page 8: Set-Up Information

    Turn ON Picasso Plus and Picasso Lite Plus • Verify Red Emergency button (FIGURE 1, Item #4) is pushed in. NOTE: Presets 5 and 6 are exclusive to Picasso Plus ONLY • Turn power switch to ON position (FIGURE 1, Item #10).
  • Page 9 ITEM DESCRIPTIONS Step 1: Select one of the six Presets (Picasso Plus) or one of the four presets (Picasso Lite Plus). If the selected preset is a Continuous Mode, Interval and Duration are not available. Power is able CONT MODE; POWER: 1.8W to be selected and saved as a preset.
  • Page 10 Use high-speed suction as required to maintain a clear field of vision during treatment. Do not use Picasso Plus and Picasso Lite Plus if you cannot clearly see the treatment site. It is recommended that a smoke evacuator or in-line filter be used to capture the plume during the treatment of herpetic lesions, INSTRUCTIONS FOR USE oral papillomas, and whenever possible.
  • Page 11 CaviCide™ or other equivalent solution following manufacturer’s instructions. If • 300 µm and 400 µm tips may be used according to the Picasso or Picasso Lite duty cycle up to using any product containing alcohol, make sure to allow tip to air dry fully prior to re-initiating the tip.
  • Page 12 FIGURE 7 hear a click. labeled as “autoclavable”. NOTE: The AMD Lasers logo should face up on the adapter, and the notch on the adapter should align with the Quadra Tip peg. FIGURE 9 The Quadra Tip is used 1–2 mm from the teeth once the bleach is placed on the teeth. Do not contact the patient with the Quadra Tip.
  • Page 13 The contamination control suggested for fiber optic cable, handpiece, and interchangeable tips is the To Connect Legacy Handpiece (FIGURE 8-1) to Fiber Optic Assembly: system sterilization method. However, before sterilization, Picasso Plus and Picasso Lite Plus reusable 1. Loosen handpiece base (FIGURE 11) accessories (handpiece, fiber optic cable, and interchangeable tips) should be carefully cleaned per the 2.
  • Page 14 In REPEAT / PULSE mode, the laser will deliver output radiation at the power level specified by the user and in a pulse format defined by the user for Picasso Plus...
  • Page 15 Picasso Lite Plus. In pulse mode, the wattage is reduced meaning that a setting on 1.0 W in pulse PRODUCT SPECIFICATION mode may produce average power of 0.5 W at the tip if the duty cycle is 30ms on and 30ms off (50% duty cycle).
  • Page 16 • • Laser Operation Note: 0.5–5.0 W Continuous Operation paper is included with each Picasso laser. Select the SPEED or HYGIENE MODE preset and drag the tip >5.0 W Intermittent Operation 2 min on, 5 min off or onto the articulating paper while firing the laser.
  • Page 17 If you have any questions regarding transportation, please call ANNUAL MAINTENANCE your authorized representative or AMD Lasers. Picasso Plus and Picasso Lite Plus should be serviced annually by a qualified, AMD Lasers’ FOOTSWITCH BATTERY REPLACEMENT trained technician. Please, contact your authorized representative or AMD Lasers to discuss annual maintenance options.
  • Page 18: Low Foot Switch Battery Error

    The Picasso Plus and Picasso Lite Plus Dental Laser units are factory calibrated. For accurate treatment The Picasso Plus and Picasso Lite Plus lasers have an ability to provide operator with warnings and results, the unit(s) should be calibrated every 12 months following the date of purchase. It is required that errors.
  • Page 19: Internal Fault-Service Required Error

    HIGH LASER MODULE TEMPERATURE ERROR This warning appears when the wireless foot switch battery is low which is under 7V. You can clear the message from the screen by tapping the triangle area as long as the foot switch battery voltage is greater than 6.5V and continue using the laser.
  • Page 20: Calibration Required Error

    This pop-up will remain in place regardless of whether the error automatically corrects itself. You will be customer or the user of the Picasso Plus or Picasso Lite Plus laser should assure that it is used in such an environment.
  • Page 21 The Picasso® Plus and Picasso Lite® Plus are intended for use in the electromagnetic environment specified below. The customer or the user of the Picasso Plus or Picasso Lite Plus laser should assure that it is used in such an environment.
  • Page 22: Annex A: Labels

    The Picasso® Plus and Picasso Lite® Plus are intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Picasso Plus or Picasso Lite Plus laser can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications...
  • Page 23 Manufacturer Label (Picasso Lite Plus) Picasso Lite Plus Logo AMD LASER Logo Laser Danger Label for Optical Fiber (Picasso Plus & Picasso Lite Plus) and Warning for Laser Aperture Port IEC Explanatory Label (Picasso Plus and Picasso Lite Plus) R.C.
  • Page 24: Annex B: Accessories

    400µm Strippable Fiber - ST Connector SF400-ST Laser Whitening Gel Kit (5) WG-5 200µm Fiber With Multi Tip Handpiece, FC, Black Jacket for Picasso Lite Plus MTHP-PL QUADRA Tip Multi Tip Hand Piece 300µm Fiber With Multi Tip Handpiece, FC, Orange Jacket for Picasso Plus...
  • Page 25: Amd Lasers: Terms And Conditions Of Sale

    FOUND TO BE DEFECTIVE IN MATERIALS OR WORKMANSHIP, AMD LASERS SHALL REPAIR OR REPLACE AT ITS IF YOU ARE NOT SATISFIED WITH THE PICASSO PLUS / PICASSO LITE PLUS, AMD LASERS EXTENDS THE DISCRETION SUCH DEFECTS IN MATERIALS OR WORKMANSHIP AND SHALL NOT CHARGE THE OWNER/USER OPPORTUNITY TO OBTAIN A FULL REFUND OF THE PURCHASE PRICE OF THE PRODUCT (NOT INCLUDING FEES, ONLY FOR MATERIALS ASSOCIATED WITH SUCH REPAIR OR REPLACEMENT.
  • Page 26: Limited Liability

    LIMITED LIABILITY AMD LASERS WILL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, OR SPECIAL DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF REVENUE, LOSS OF BUSINESS OR BUSINESS OPPORTUNITY, OR OTHER SIMILAR FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE, USE, OR INTERRUPTED USE OF THE “PICASSO”...
  • Page 27 866.999.2635 www.amdlasers.com 4628 West Skyhawk Drive West Jordan, UT 84084 © 2021 AMD Lasers, Inc. All Rights Reserved. 03758.v05.21...