Control Panel Model
Blackfire CST-2-T
INSTALLATION MANUAL
Pagina 1 de 48

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CST-2-T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Blackfire CST-2-T

  • Page 1 Control Panel Model Blackfire CST-2-T INSTALLATION MANUAL Pagina 1 de 48...
  • Page 2: Table Of Contents

    Index Presentation ............................3 Introduction to the system ........................ 3 Technical specifications ........................4 Security of system use ........................5 Product Description ........................... 5 Version ............................... 5 System installation ..........................5 7.1. Fixing the chassis ..........................6 7.2. Wiring Installation (Connection)......................7 7.3.
  • Page 3: Presentation

    Upon receiving a fire alarm signal or in case of general failure, the control panel will send an order to drop the curtains, closing the gap to be sectorized or compartmented CST-2-T are autonomous systems by means of an integrated UPS module that guarantees an autonomy of 4-6 hours of operation in case of main power supply failure.
  • Page 4: Technical Specifications

    960W. Battery Charger (8): Battery Charger with output of 27.6 Vdc 40A. Controller card (9): COLECT controller card for the management and activation of Blackfire MSB & MFB systems. Main’s terminal block (10): Isolated terminal block. Optional: Scape Buttons: For automatic opening and closing in case of emergency.
  • Page 5: Security Of System Use

    4. Security of system use The CST-2-T control switchboards must be installed in visible areas due the signals and indicators located on the front of the panel and in accessible places to be able to perform maintenance tasks such as battery replacement, operation tests, etc.
  • Page 6: Fixing The Chassis

    7.1. Fixing the chassis The control panel shall be fixed considering its dimensions and, by means of the attachment points described in the following figure, shall be installed in an accessible place for subsequent maintenance: Special care must be taken not to damage electronic components or wiring when introducing mechanical tools (drills, screwdrivers, etc.).
  • Page 7: Wiring Installation (Connection)

    4 mm2 60 – 80 mts 6 mm2 * Note: If longer distances are necessary, the technical department of Blackfire should be consulted. • Communication Terminal Block: Conductors with minimum gauge AWG 15 (1.5 mm2) with mesh, according to the description of the terminal will be used.
  • Page 8 Warnings: ➢ Blackfire is not responsible for damages caused by a bad connection derived from the non-reading or misunderstanding of this manual, in case of doubt please contact our technical department. ➢ All the connection of the system must be made without power, the main power will not on until all the connections, including the alarm signal, have been made.
  • Page 9 Pagina 9 de 48...
  • Page 10: Installing Cmt-20 Motor Controller Cards

    7.3. Installing CMT-20 motor controller cards The CMT-20 motor modules are programmable elements that regulate and manage, the speed of descent, the uptime, and the control at rest of the motors. The main features are as follows: • Stop by overcurrent detection: When the counterweight bar touches against the bottom of the container box in MSB &...
  • Page 11 The control card CMT-20 has a series of led status indicators. LED 18 (RED) ACTIVE: Over-temperature in SMK 2A & 5A motors. The 24 Vdc output is disconnected to the motor. LED 18 (RED) BLINKING: Fallo de comunicaciones. Se desconecta la salida 24 Vdc a motor. LED 19 (GREEN) FAST BLINKING: CMT-20 in RUN mode (UP manoeuvre).
  • Page 12: Commissioning Of The System

    7.4. Commissioning of the system. Once all the appropriate connections described in the previous point have been made and verified, we will proceed to place the test key in a horizontal position (Alarm Mode) BEFORE FEEDING THE CONTROL PANNEL WITH MAIN CURRENT 220 Vac. Item 3: Test key, turn the test key to its horizontal position, active alarm position Once this step is done, we will proceed to feed the panel with main current 220 Vac.
  • Page 13 This page is the initial one of the system that shows the generic information of the curtain and the icons of user interaction. 1 QR Code. The code allows us access to the Blackfire website. 2 Name and reference. Shows the name of the project and reference of the curtain according to the client's indications.
  • Page 14 Contact Area The screen will show the company data for its location or contact information.. 1 Data area. 2 Interaction buttons. On this page the user will not have any more navigation possibilities, they will only be able to return to the initial page.
  • Page 15 Help Area It will display the help pages for the user. In these pages you will find information on how to navigate through the different menus, access the curtain control, status information, access to the project documentation. It will give us the option to choose the language before accessing. 1 Language selector.
  • Page 16 1 General documentation. The user has the option of accessing the general documentation of the system. This section contains the documentation for the system manuals and the control panel manual. 2 Specific documentation. The user has the option of accessing the specific documentation of the project. This section contains the installation documentation and maintenance manual.
  • Page 17 5 Status indicators. Represented the different status icons of each of the alarms that are displayed on the screen and show the detail of their condition. 6 Help Pages. In this menu the user can scroll through the different help sections with the numeric buttons. 7 Interaction buttons.
  • Page 18 General Documentation Section 1 QR Code. By reading the QR code, the user accesses the general documentation folder for his project located on the Blackfire servers. The files that are saved in this file can only be modified by Blackfire.
  • Page 19 1 QR Code. By reading the QR code, the user accesses the specific documentation folder of his project, which will only have exclusive access if accessed with password permissions, located on Blackfire servers. The files that are saved in this file can only be modified by Blackfire.
  • Page 20 It can only be accessed using the correct password. In the event that the password is incorrect, the user will see a page in which they will be informed that the password is incorrect and the contact details of Blackfire for the contact..
  • Page 21 Home Section In this area the user can view the following information: 1 Name and reference. Shows the name of the project and reference of the curtain according to the client's indications. 2 Curtain status. Shows depending on the movement that the curtain is making, in which state it is, Raising, Lowering, Stop or Maintenance 3 Status of alarm sensors.
  • Page 22 It can only be accessed using the correct password. In the event that the password is incorrect, the user will see a page in which they will be informed that the password is incorrect and the contact details of Blackfire for the contact.
  • Page 23 EDIT Section 1 Name and reference. Shows the name of the project and reference of the curtain according to the client's indications. 2 Emergency rising time (ms). Parameter that assigns the time for the emergency button to raise the curtain and for it to remain stopped.
  • Page 24 RTC Section In this area the user can view the following information: 1 Date. RTC date setting with dd/mm/yy format. You can increase or decrease the digits with the “+” or “-“ buttons respectively. 2 Hour. RTC time setting in hh:mm:ss format. You can increase or decrease the digits with the “+” or “-“ buttons respectively. 3 Save.
  • Page 25 WIFI Section In this area the user can configure the Wi-Fi network connection of the control panel: 1 Data. Name and password of the Wifi network to which the user connects the control panel. 2 Information icons. The user can send the LOG and INI configuration files via previously configured email. 3 Save.
  • Page 26 DRVs Section 1 NumDRVs. Parameter that corresponds to the total number of drivers that the curtain has. You can increase or decrease the value with the “+” or “-“ buttons respectively. 2 rs485 BAUD. Communications bus speed. 3 maxTimeUP(s). Parameter that assigns the maximum time that the curtain can carry out in the raising manoeuvre. Value displayed in seconds.
  • Page 27 Log Section On this page the user will be able to view the last 15 events that the curtain has had and will be able to send them via email to have their registration. 1 Name and reference. Shows the name of the project and reference of the curtain according to the client's indications. 2 Table of Events.
  • Page 28: Troubleshooting

    8. Troubleshooting During system installation or maintenance, various problems may occur. The resolution of these must be executed by the installation company, in most cases they can be resolved according to the following table: PROBLEM CAUSE SOLUTION - Connection. - Check input connection 220 Vac. Control Panel does not turn on - Check main power line.
  • Page 29: Maintenance And Cleaning

    9. Maintenance and Cleaning Since fire curtains and smoke control curtains are a product of high importance in terms of fire safety, the owner of the building has the obligation to keep the curtains in good working order, being inspected and tested regularly. To ensure the reliability and integrity of textile roller fire curtains, the system must be inspected, evaluated, and repaired by trained and qualified personnel for product maintenance.
  • Page 30: Annexes

    Annexes: ELEMENTO / ITEM MATERIAL DESCRIPCION / DESCRIIPTION PANTALLA TÁCTIL / TOUCH SCREEN LLAVE DE APERTURA PUERTA / DOOR PLASTICO / PLASTIC OPENING KEY LLAVE DE TEST / TEST KEY METAL / METAL Pagina 30 de 48...
  • Page 31 ELEMENTO / ITEM MATERIAL DESCRIPCION / DESCRIIPTION BATERIAS / BATTERIES 2 PCS 12V 7.2 Ah (STANDAR) FUENTE DE ALIMENTACION 27 Vdc potencia según modelo POWER SUPPLY 27 Vdc power acording model CARGA BATERIAS 27.6 Vdc 40A UPS MODULE TARJETA CONTROLADORA COLECT TARJETA CONTROLADORA COLECT BOARD BOARD BORNERO PRINCIPAL PARA EL CONEXIONADO DE ALIMENTACION, ALARMA Y SALIDA...
  • Page 32 DETALLE / DETAIL BORNE ENTRADA 24 Vdc 24Vdc INPUT TERMINAL BORNE SALIDA 24 Vdc CONDICIONADA SEÑAL FUEGO 24Vdc OUT TERMINAL FIRE SIGNAL CONDITION BORNE LLAVE DE TEST KEY TEST TERMINAL ENTRADA SEÑAL FALLO BATERÍAS BATTERY FAILURE SIGNAL IN ENTRADA SEÑAL FALLO DE RED MAINS POWER FAILURE SIGNAL IN BORNE ALARMA FUEGO FIRE ALARM TERMINAL...
  • Page 33 ELEMENTO / ITEM DETALLE / DETAIL ZUMBADOR ACUSTICO / ACOUSTIC BUZZER ZUMBADOR ACUSTICO EN CASO DE ALARMA / ACOUSTIC BUZZER IN CASE OF ALARM POTENCIOMETRO VELOCIDAD FRENO POTENCIOMETRO ENCARGADO DE REGULAR LA VELOCIDAD DE DESCENSO POTENTIOMETER IN POTENTIOMETER VELOCITY BRAKE CHARGE OF REGULATING THE SPEED OF DESCENT DISIPADOR DE TEMPERATURA GENERADA EN EL SISTEMA DE FRENADO ELEMENT HEATSINK FOR DISIPADOR FRENO / BRAKE HEATSINK...
  • Page 34 Pagina 34 de 48...
  • Page 35 Pagina 35 de 48...
  • Page 36 Pagina 36 de 48...
  • Page 37 Pagina 37 de 48...
  • Page 38 Pagina 38 de 48...