® Digital I/O UCERB 24 USB Electromechanical Relay Module - 24 SPDT (Form C) Relays, with 24 Screw Terminals USER’S MANUAL VER. 4 • MAY 2005 No part of this manual may be reproduced without permission ® CyberResearch , Inc.
Page 5
CyberResearch, Inc. In no event will CyberResearch, Inc. be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of or inability to use the product or documentation, even if advised of the possibility of such damages.
Software ...5 Unpacking the UCERB 24...6 Installing the UCERB 24 ...6 Configuring the hardware switches ...6 Connecting the external power supply ...7 Connecting the UCERB 24 to your system ...8 Installing the software...9 Chapter 3 Functional Details ...14 Internal components...14 USB in connector...14...
What you will learn from this user’s guide This user’s guide explains how to install, configure, and use the UCERB 24 so that you get the most out of its electromechanical relay features. This user's guide also refers you to related documents available on our web site, and to technical support resources.
USB port in a daisy chain fashion. Depending on your load requirement, daisy chained boards may require a separate power supply. The UCERB 24 is shipped in a rugged enclosure that you can mount on a DIN rail or on a bench. ®...
Switch S2 (inv/non-inv) (pull-up/down) Figure 1-1. UCERB 24 functional block diagram Software features The InstaCal installation, calibration, and test utility software ships with the UCERB 24 free of charge. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA UCERB 24...
UCERB 24. No third-party device driver is required. You can connect the UCERB 24 before or after you install the software, and without powering down your computer first. When you connect an HID to your system, your computer automatically detects it and configures the necessary software.
CyberResearch Digital I/O Installing the UCERB 24 What comes with your UCERB 24 shipment? The following items are shipped with the UCERB 24. Hardware The following items should be included with your shipment. UCERB 24 External power supply and cord – 9 volt, 3 amp DC power supply...
Installing the UCERB 24 The UCERB 24 has two on-board switches that you set to configure the relay logic polarity and the resistor pull-up/down configuration. Configure these switches before you connect the external power supply to the UCERB 24. Factory-configured default settings are listed in Table 2-1. Refer to Figure 3.1 for the location of each switch on the UCERB 24.
PULL-DOWN Connecting the external power supply Power to the UCERB 24 is provided with the 9 V, 3 A external power supply. You must connect the the external power supply before connecting the USB connector to the UCERB 24. To connect the power supply to your UCERB 24, do the following:...
Connecting the UCERB 24 to your system To connect the UCERB 24 to your system, turn your computer on, and connect the USB cable to a USB port on your computer or to an external USB hub that is connected to your computer. The USB cable provides communication to the UCERB 24.
1. Close all applications you have running, including anti-virus software. 2. Insert the CyberResearch Software CD into your CD drive and let autorun. Choose whether or not to install the .NET Framework 1.1 If the .NET Framework 1.1 is already installed on your computer, proceed to the Install the DAQ Software section.
Page 19
3. Read the information on this dialog. If a warning dialog opens during this installation asking to allow scripts to run, click the appropriate option that allows them to run. 4. Click on the Next > button. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA UCERB 24 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
Page 21
If you are going to install the Universal Library or Universal Library for LabVIEW, you can install either of the packages before you restart. Unpack and install your USB device after your computer restarts. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA UCERB 24 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
UCERB 24. The chained products from a single external power supply. Depending on your load requirements, daisy chained products may require a separate power supply. Refer to "Power limitations using multiple UCERB 24 devices" for more information.
® CyberResearch Digital I/O USB LED LED indicates the communication status of the UCERB 24. It uses up to 5 mA of current and cannot be disabled. Ta ble 3-2 explains the USB LED function. USB LED Indication illumination The UCERB 24 is connected to a computer or external USB hub.
To daisy chain two or more UCERB 24 relay boards, follow the steps below. This procedure assumes you already have one UCERB 24 connected to a computer and to an external power source. The UCERB 24 already connected to the computer is referred to as the connected module. The UCERB 24 you want to daisy chain to the connected board is referred to as the new module.
Power limitations using multiple UCERB 24 devices When daisy chaining additional CyberResearch products to the UCERB 24, you must ensure that you provide adequate power to each board that you connect. The UCERB 24 is powered with a 9 VDC nominal, 3.0 A external power supply.
Settings can be read back via software. Pull-down will put the relays in non-energized mode on power up. Pull-up will put the relays in energized mode on power up. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA Table 4-1. Output specifications UCERB 24 Chapter 4 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
Voltage supervisor limits - PWR LED (Note 1) External power adapter (included) The UCERB 24 monitors the external +9 V power supply voltage with a voltage Note 1: supervisory circuit. If this power supply exceeds its specified limit, the PWR LED will turn off indicating a power fault condition.
436.9 mm (L) x 132.1 mm (W) x 40.6 mm (H) 17.2" (L) x 5.2" (W) x 1.6" (H) 0 to 70 °C -40 to 100 °C 0 to 95% non-condensing Screw terminal 12 to 22 AWG UCERB 24 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
Signal connections and programming are the two most common sources of difficulty. CyberResearch support personnel can help you solve these problems, especially if you are prepared for the call.