molex MIIM SCANNER Installation Instructions Manual

Hide thumbs Also See for MIIM SCANNER:

Advertisement

MIIM™ SCANNER INSTALLATION INSTRUCTIONS
IMPORTANT
PLEASE READ THIS DOCUMENT FIRST BEFORE ATTEMPTING TO INSTALL OR OPERATE THE MIIM SCANNER
Product Covered: Molex Part Number IMS-00100
This document contains:
Scanner installation instructions
MIIM System Warranty, Disclaimers, and Limitations of Liability
MIIM System Software License Agreement and Limited Warranty
Please read this document prior to installing and/or powering the MIIM Scanner. Please be aware that proceeding with
powering, configuring, or using the MIIM Scanner binds you and any subsequent users of the scanner to the terms and
conditions of the MIIM System Sofware License Agreement.
Important Safety Notices
The MIIM Scanner is powered by either 110-volt or 220-volt AC. As with all AC powered devices it is important that
all applicable local electrical regulations be followed during installation of this device.
For North America, equipment must be installed in accordance with applicable requirements of the National
Electrical Code® and/or the Canadian Electrical Code.
Do not allow this device to come into contact with, or become immersed in, water or other liquids.
Clean only with a dry cloth.
This product must be installed in an environmentally controlled area, with appropriate heat and humidity controls.
Allow for adequate ventilation around the unit to maintain normal operating temperature. Do not block any ventilation
openings.
Do not attempt to open the case, disassemble, or alter any portion of this device. Any unauthorized opening of the
case or tampering with the components inside will void the warranty.
Do not attempt to connect Ethernet circuits into any of the RJ45 jacks on the rear of the unit - these jacks are
Communication Bus Ports
Replacement of battery with incorrect type will result in risk of explosion. Dispose of batteries properly.
Product Overview
The MIIM scanner communicates with the MIIM patch panels to collect data regarding changes in the physical structured
cable plant and to drive patch guidance LEDs on the panels. The scanner is connected to each patch panel through
industry-standard RJ45 patch cords. The scanner also provides power to all the patch panels through the communication bus
cables.
Each scanner can be connected to forty-eight 24-port MIIM patch panels, providing for a total capacity of 576 channels in
a cross-connect environment. The following figure shows the general architecture of a MIIM System, and illustrates how the
scanner communicates with both the server and MIIM patch panels.
Doc #AS-18700-052, Rev A
strictly for connecting
Communication Bus Cable
Form # 215-384
Copyright © 2009 Molex. All Rights Reserved
s to MIIM patch panels.
MIIM System Architecture
SAP #187000363
Rev Date: June 2009
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MIIM SCANNER and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for molex MIIM SCANNER

  • Page 1 MIIM™ SCANNER INSTALLATION INSTRUCTIONS IMPORTANT PLEASE READ THIS DOCUMENT FIRST BEFORE ATTEMPTING TO INSTALL OR OPERATE THE MIIM SCANNER Product Covered: Molex Part Number IMS-00100 This document contains: • Scanner installation instructions • MIIM System Warranty, Disclaimers, and Limitations of Liability • MIIM System Software License Agreement and Limited Warranty Please read this document prior to installing and/or powering the MIIM Scanner. Please be aware that proceeding with powering, configuring, or using the MIIM Scanner binds you and any subsequent users of the scanner to the terms and conditions of the MIIM System Sofware License Agreement. Important Safety Notices ►...
  • Page 2: Items Not Included

    Communication Bus Ports for Horizontal Panels 110/220 VAC Power Items Not Included To complete the installation of the MIIM Scanner you will need to procure: • One power cord, to connect the MIIM Scanner to a 110-volt or 220-volt AC power supply. The end of the power cord that connects to the scanner must be equipped with an IEC-60320 C13 power connector. For North American applications use a powercord that is UL-listed or CSA certified, the cord must be 3-conductor, 18 AWG, not longer than 4.5 meters, with a plug rated for 125V and I5A. For European applications use a power cord that is internationally harmonized and marked <HAR>, 3-conductor 0.75mm² minimum wire, rated 300V with a PVC jacket and plug rated for 300V and 10A. • Communication Bus Cables – one cable is required for each MIIM patch panel that is to be connected to the scanner. These cables must be 8-wire, minimum 24 AWG conductors, and must be equipped with industry-standard RJ45 connectors at both ends. In general any standard Category 5e UTP or better patch cord will work. The maximum allowable length of the communication bus cable is 100 meters. Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 2...
  • Page 3: Installation Steps

    Connect a ground (earth) bond wire from the scanner to an appropriate bonding point on the rack or cabinet. Connect the bonding wire to either the stud on the rear of the scanner case (appropriate for 18 AWG wire connection) or the stud on the wire manager (for wire connections up to 10 AWG). Bonding stud for wire size up to 10 AWG Connect AC power. Be sure to secure the power cord so that it does not become pinched, is protected from being stepped on and does not become a trip hazard. The status lights S3-S6 should now be on. Power Cord Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 3...
  • Page 4 “Debug.” In the box titled “Test Panel LEDs” enter a panel number (1-24) and press “Start.” The patch guidance lights on both the associated CC and PP panels should come on in sequence. Click “Stop” to end the Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 4...
  • Page 5: Next Steps

    test. One port LED will remain lit on each panel that has been tested to indicate that testing has been performed. These LEDs will remain lit until power is disconnected from the scanner (step 10). It is recommended that you check all panels this way. j. When finished with testing, sign out of the web interface, exit from your web browser, and disconnect your PC from the scanner “Console/LAN 2” port. k. Reset the IP configuration of your PC to its original configuration. 6. Disconnect the scanner from its power source. This will clear the LEDs that remain lit. 7. When the network administrator is ready for the scanner to be connected to the network and the MIIM server, connect the scanner “LAN 1” port to the network, using a Category 5e or better patch cord, and reconnect power to the scanner. Next Steps: This completes the basic hardware installation steps of the scanner. You are now ready to begin initializing the MIIM application server and establishing communication between the server and scanner. This process is not covered here - refer to the “MIIM Server Installation Guide” for details. Status lights S1 and S2 on the front of the scanner will remain off until a communication link has been established between the scanner and the MIIM application server. Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 5...
  • Page 6: Supplementary Information

    In the this connection uses the following items box, click Internet Protocol (TCP/IP), and then click Properties. The Internet Protocol (TCP/IP) Properties dialog box appears. Click Obtain an IP address automatically. Click Obtain DNS server address automatically if you do not want to specify the IP address of the Domain Name System (DNS) server. Click OK. In the Local Area Connection Properties dialog box, click OK. Click Start, and then click Run. In the Open box, type cmd, and then click OK. At the command prompt, type ipconfig /release, and then press ENTER. Type ipconfig /renew, and then press ENTER to confirm the new IP settings. Type exit and then press ENTER to quit the command prompt Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 6...
  • Page 7: Considérations De Sécurité

    Il existe un risque d’explosion si les piles sont remplacées par des piles d’un type incorrect. Jetez les piles usées selon les instructions. ‫ة م ا‬ ‫ه ة‬ ‫م ا ل‬ ‫س‬ ‫ت‬ ‫ا ر‬ ‫ا ع‬ ‫ش‬ ‫إ‬ Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 7...
  • Page 8 Application Assurance. If the MIIM Certified Cabling System prevents the endues from operating an industry-standard application /protocol then we will diagnose and repair or provide replacement product at our sole discretion to ensure the effective transmission of the said application/protocol. Return and Repair You may obtain technical support for the Products as follows: Call your local Molex Customer Service representative to report the problem - please refer to the “Our offices” section of the website www.molexpn.com. Be prepared to provide the Product part and serial numbers, date of purchase, the nature of the problem, any corrective action you may have tried, and your contact information. If the Customer Service representative is unable to resolve the issue on a first phone call a representative from Technical Support will follow up with you. During these subsequent calls you may be asked to provide detailed information regarding the MIIM application, and we may ask you to submit copies of activity logs and other database information. We may also ask for remote access to the MIIM Application Software and database. In the event that the issue can not be resolved via phone, and, if the Product is under warranty, Molex will propose a resolution that may include but not be limited to returning the Product in exchange for a new unit, or may involve a site visit by Molex personnel to see if the fault can be corrected in the field. If a replacement part or Product is needed, it will be sent to your location free of charge, and you are required to return the defective part or Product back to Molex after receipt of the replacement unit using the packaging from the replacement unit. You will be given the return address and tracking number to include with the returned Product. Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 1...
  • Page 9 MIIM™ System Warranty, Disclaimers, and Limitation of Liability If the warranty period on the Product has expired you may chose to purchase a new unit, or return the existing unit to Molex for an estimate of repair time and cost. Alternatively, you may opt to have a Molex technical services representative visit your location to diagnose the trouble and determine a course of action. The fee for out-of-warranty on-site visits and service will be at Molex’s then-current rates, in addition to costs and expenses. Limitations and Disclaimers The aforementioned warranties extend only to the original end-user of the Product for whom it was installed and is not transferable. MOLEX EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES OF ANY KIND WHATSOEVER AS TO THE PRODUCTS, INCLUDING, BUT NOT LIMITED TO, EXPRESS OR IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND DESCRIPTION OR QUALITY OF THE PRODUCTS.
  • Page 10 (B) The Software, its code, and all Documentation are owned by Licensor or its subcontractors. The organization, structure, and code of the Software are valuable trade secrets of Licensor or its subcontractors. The Software, its code, and all Documentation are protected by U.S. Copyright law and International Treaty provisions. You may not, in whole or in part, disclose, provide, make available, copy, photocopy, reproduce, translate, adapt, modify, or create derivative works, or reduce to any electronic medium or machine readable format, the Software, its code, or the Documentation, except as specifically set forth elsewhere in this Agreement, without the prior written consent of Licensor. You also may not reverse engineer, decompose, disassemble, or otherwise attempt to discover or alter the source code of the Software. (C) MIIM™ is a trademark of Licensor. You may not use any trademark of Licensor except in accordance with Licensor’s trademark usage policies. III. Transfer The Software and the Documentation may not be rented, leased or sublicensed. The purchaser of the scanner products and/or patch panel hardware may, however, transfer all rights to use the Software to another person or legal entity provided that such other person or legal entity agrees to the terms hereof in writing. Such transfer must involve the transfer of ownership and control of the scanner products and the patch panel hardware to such person or entity. Except as provided by this Agreement, any attempt to lease, sublicense, assign, or transfer any of the rights, duties, or obligations under this Agreement shall be void. Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 1...
  • Page 11 VII. Limitation of Liability IN NO EVENT WILL LICENSOR, ITS SUPPLIERS OR AFFILIATES, BE LIABLE FOR: (I) ANY AMOUNT OF LIABILITY OR DAMAGES IN EXCESS OF THE LICENSE FEES PAID FOR THE SOFTWARE GIVING RISE TO LIABILITY OR DAMAGES; OR (II) ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT, OR SPECIAL DAMAGES ARISING OUT OF USE OF THE SOFTWARE, INCLUDING ANY LOST PROFITS, LOST SAVINGS, INCONVENIENCE, EXPENSE FOR SUBSTITUTE EQUIPMENT OR SERVICES, STORAGE CHARGES, OR LOSS OR CORRUPTION OF DATA, EVEN IF LICENSOR HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. NEITHER WILL LICENSOR BE LIABLE FOR CLAIMS OF ANY THIRD PARTY. Without limiting the foregoing, you assume all risks and liability for loss, damage or injury to you and your property and to others and their property arising out of the use, misuse or inability to use the product, unless directly caused by the gross negligence of Licensor. Some states or jurisdictions may not allow the limitation or exclusion of liability for incidental, special, or consequential damages, so a portion or all of the above limitation may not apply to you. You acknowledge that Licensor’s obligations to you with respect to the Software are governed solely by this Agreement, and you expressly waive your right to assert any claim against Licensor arising under tort law, including, but not limited to, negligence, gross negligence, willful, reckless or wanton conduct, negligent misrepresentation, innocent misrepresentation, fraud, claims for failure to exercise due care in the performance of services hereunder, and/or strict liability, as well as any other claim under any other legal or equitable theory other than a claim of material breach of this Agreement. THE SOFTWARE IS NOT DESIGNED OR INTENDED FOR USE, AND SHOULD NOT BE USED OR SOLD OR RESOLD FOR USE, IN ANY Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 2...
  • Page 12 XII. Relief Licensee acknowledges that any violation of this Agreement by Licensee will cause irreparable injury to Licensor, and Licensor shall be entitled to injunctive relief. XIII. General This Agreement merges all prior written and oral communications and defines the entire agreement of the parties concerning the Software and Documentation. The failure by either party at any time to enforce its rights under this Agreement will not be construed as a waiver of such rights, nor will it in any way affect the validity of this Agreement. No waiver by either party will be valid unless given in an appropriate writing signed by both parties. XIV. Third Party Software Rights The Software may contain code from third party software vendors, who retain all rights in and to their code. Furthermore, the use of the Software shall be subject to the terms and conditions of use of such third party software vendor. Doc #AS-18700-052, Rev A Form # 215-384 SAP #187000363 Rev Date: June 2009 Copyright © 2009 Molex. All Rights Reserved Page 3...

This manual is also suitable for:

Ims-00100

Table of Contents