Legal notice The operating manual is valid for: LISSMAC dry vacuum cleaner VACUUM-DRY 102 BAG Headquarters: LISSMAC Maschinenbau GmbH Lanzstrasse 4 D - 88410 Bad Wurzach Phone: +49 (0) 7564 / 307 - 0 Fax: +49 (0) 7564 / 307 - 500 lissmac@lissmac.com...
Page 4
BASIC SAFETY INSTRUCTIONS Warning information and symbols in this Manual SIGNAL WORD Type and Source of Danger Consequences if not observed Measures to take to avert the danger. The signal word after the hazard symbol indicates the level of danger: This indicates an extremely dangerous situation.
Page 5
The following warning and safety instructions are used: Read operating instructions. Wear safety glasses. Wear gloves. Wear dust mask. Wear suitable work clothes and wash dusty clothes. Danger of having your hand crushed. Hazardous electrical voltage Sound level of the machine. Instruction for damage prevention.
Page 6
OPERATING INSTRUCTIONS Preface This Operating Manual should make it easier to become familiar with the machine and facilitate its use in accordance with its intended possible applications. The Operating Manual contains important information on how to operate the machine in a safe, proper and economical manner.
Features & Benefits ......................8 Table of contents General safety notes ......................9 2.1. Purpose; intended use ...................... 9 2.2. Organisational Measures....................10 2.3. Choice of personnel and qualification; fundamental obligations ........10 2.4. Safety information relating to the phases of use ............11 2.4.1.
FEATURES & BENEFITS The VACUUM-DRY dry vacuum cleaner quickly and effectively removes dust generated during sanding and cutting work. Of course, it can also be used as a regular vacuum cleaner. The highly efficient filters are automatically cleaned alternately, but can also be shaken manually at any time at the touch of a button (vibrator).
Intended The LISSMAC VACUUM-DRY 102 BAG dry vacuum cleaner consists of a suction unit with an upstream filter unit and a collection container designed as an endless hose. It is used exclusively for the extraction of dry material.
2.2. Organisational Measures The operating instructions must be kept within easy reach at the machine's place of use. Keep these instructions for future reference. Supplements to the operating manual include general statutory and other binding regulations for preventing accidents and protecting the environment and must be obeyed. Such regulations may also deal with, for example, the handling of hazardous substances, the wearing of personal protective equipment and with road traffic regulations.
2.4. Safety information relating to the phases of use 2.4.1. Transport, assembly Do not transport the machine unless all parts of the machine are tightened. Make sure that it is impossible for any part to fall. 2.4.2. Commissioning Inspect the dry extraction system for damage and defects. Particularly check the protective devices and the suction hose.
2.4.5. Electrical Power Only connect the machine to a socket protected by a residual current circuit breaker (30 mA, 30 ms) with a protective contact. Do not connect the machine to multiple sockets. Only use extension cables of type H07 RN-F with a sufficient cable cross-section. (see 5.1) Always unwind cable reels completely.
2.5. Packaging And Storage In order to ensure sufficient protection during dispatch and transport, the machine and its components were packed carefully. The machine should be checked for damage upon receipt. The packing of the device consists of recyclable materials. Place them into the containers provided for recycling so that they can be recycled.
DEVICE DESCRIPTION 3.1. Names Of The Machine Parts Pos. 1 On-off switch Pos. 7 Handle for motor unit Pos. 2 Handles for moving Pos. 8 Button for manual filter cleaning Pos. 3 Hand lever for container (rear) Pos. 9 Release lever Pos.
3.2. Technical Data VACUUM-DRY 102 BAG Dust container (endless bag) 22 m Longopac ® Ø 360mm Electrical power 2.4 kW Operating voltage AC 230V 50/60Hz Protection type IPX4 Filter cleaning automatic / additional manual Filter class HEPA 14 + PTFE Filter area primary filter 3.0 m²...
Page 16
3.3. Special hazards: Dust WARNING Inhalation of fine silica dust Grinding concrete and natural stone can produce fine silica dust that causes irreversible damage to the lungs if inhaled (silica). Always wear personal respiratory protection equipment when cleaning and changing ...
TRANSPORT 4.1. Transport position CAUTION Danger of crushing The machine has a high centre of gravity. Danger of injury due to tipping or slipping of the machine. Empty the dust container before transport Activate the parking brake on the castors ...
OPERATION 5.1. Safety General Rules • Keep the machine clean and operate only in a technically flawless condition. • The machine is not authorised for outdoor use in wet conditions, precipitation or condensing humidity. • Ensure that the machine is protected from any splashing water. NOTICE Observe the following minimum cross-sections when using extension cables: •...
5.4. Cutting operation NOTICE The dry extraction system is only suitable for extracting dry, free-flowing dust. Do not vacuum wet dust, otherwise the filter will clog very quickly. 5.5. Shaking the filter cartridges The filter cartridges are automatically shaken down in turn. This process can be triggered manually at any time by pressing a button Shake the filters manually before changing the bag.
5.6. Changing the dust collecting bag WARNING Substances hazardous to health The collected dust poses a risk to people and the environment. The dust must be collected, stored, transported and disposed of in accordance with national and local regulations. Workfow ...
5.7. Warning if the extraction speed is undercut The speed of the sucked-in air must not fall below 20 m/s in the suction hose. If this value cannot be maintained due to increasing saturation of the filter elements or a machine defect, the machine indicates this as follows: •...
5.8. Replace air filter cartridges CAUTION Dust leakage The machine contains harmful dust. Only trained personnel may service and empty the machine. Always wear personal protective equipment. (Protective mask at least FFP2, safety goggles and gloves) Minimise dust leakage at all times ...
Page 23
Replace air filter Disconnect the power supply. cartridges Put on personal protective equipment. Loosen the clamping locks Lift and remove the turbine housing. Loosen the screw connections and remove the protective sleeves. Dismantle the filter insert holders and remove the filter cartridges. Check the container and clean the sealing surfaces if necessary.
5.9. Replace Longopac® endless bag CAUTION Dust leakage The machine contains harmful dust. Only trained personnel may service and empty the machine. Always wear personal protective equipment. (Protective mask at least FFP2, safety goggles and gloves) Minimise dust leakage at all times ...
Page 25
Cut open the retaining straps. Pull the inner end of the hose inside the cassette out to the bottom edge of the cassette. Pull the outer end of the tube over the outside of the cassette to form the first bag. Insert the cassette back into the housing.
MAINTENANCE 6.1. Maintenance WARNING Danger of electric shock Risk of electric shock when servicing the appliance with an active power supply. Maintenance and repairs may only be carried out with the machine unplugged. Maintenance and repairs may only be carried out by qualified personnel. Cleaning If necessary, clean with a damp cloth.
6.2. Troubleshooting: Error Possible Cause Remedy Dust is not being extracted or only poorly The suction line is in a bad state, the Optimize hose routing. hose or transitions are leaky Remove internal incrustations. Check transitions and hose for tightness. Filter cartridges clogged Shake or replace filter elements.
ACCESSORIES / SPARE PARTS BAG Floorhead metal 50mm Floorhead plastic 38mm #1095191 #1095189 Reduction to 38 mm Inlet connection 50 mm #1095186 #1095185 Extraction hose 5m Chrome-plated suction pipe 38 mm Ø 50 mm #1095195 #1095188 Ø 38 mm #1095187 Signal light with acoustic warning Chrome-plated suction pipe 50 mm #1095193...
SPARE PARTS NOTICE Only use original accessories authorised and supplied by the manufacturer. Filter element Main filter Top container sealing rubber Filter element absolute filter HEPA 14 Bottom rubber seal container Cooling air filter element Sealing rubber cassette Blade guard cover for filter elements Filter clamp/tensioning strap Longopac®...
LISSMAC Maschinenbau GmbH, D-88410 Bad Wurzach Authorised representative: Head of Construction / Technical Documentation Machine description: The LISSMAC dry extraction unit VACUUM-DRY 102 BAG is designed exclusively for the extraction of inert, dry and free-flowing dusts. Use in potentially explosive atmospheres is not permitted. Guidelines:...
Need help?
Do you have a question about the VACUUM-DRY 102 BAG and is the answer not in the manual?