New style helical gear ratio multiplier (10 pages)
Summary of Contents for Sterling SSP 5
Page 1
Op er ating In struc tions Con veyor Hop per SSP 5 Ster ling Ma te rial Pro cess ing Download from Www.Somanuals.com. All Manuals Search And Download.
Page 2
SSP 5 Ster ling Ma te rial Pro cess ing 5200 West Clinton Ave. Mil wau kee, WI 53223 Tele phone: (414) 354-0970 Fax: (414) 354-6421 Tech ni cal ser vice: Ser vice de part ment Tele phone: (800) 423-3183...
Page 3
SSP 5 Ster ling Ma te rial Pro cess ing re tains all rights to change the in for ma tion in these op er at ing in struc tions at any time with out no tice. We as sume no li a bil ity for any er rors or di rect or in di rect dam age re sult ing in con - text with these op er at ing in struc tions.
Page 4
Please note that our address and phone information has changed. Please reference this page for updated contact information. These manuals are obsolete and are provided only for their technical information, data and capacities. Portions of these manuals detailing procedures or precautions in the operation, inspection, maintenance and repair of the products may be inadequate, inaccurate, and/or incomplete and shouldn’t be relied upon.
SSP 5 1. Safety in struc tions » These safety in struc tions ap ply to all per sons within the range of ac tion of the equip ment. Please in form all per sons within the range of ac tion of the equip - ment of the di rect and in di rect haz ards con nected with the equip ment.
SSP 5 1.1. Warn ings and sym bols The fol low ing warn ings and sym bols are used in these op er at ing in struc tions: » This sym bol in di cates dan ger to life! Fa tal or se ri ous in jury is pos si ble if the cor re spond ing in struc tions, reg u la tions or warn - ings are not ob served.
SSP 5 1.2. Ex pla na tions and in for ma tion Var i ous terms and des ig na tions are used fre quently in these op er at ing in struc - tions to en sure clar ity. There fore please note that the terms used in the text stand for the cor re spond ing ex pla na tions listed be low.
SSP 5 1.3. For your safety It is ab so lutely nec es sary that you ob serve the op er at ing in struc tions for the cor - re spond ing con vey ing sys tem. The de vice is in tended ex clu sively for con vey ing plas tic gran ules and regrind.
SSP 5 2. In stal la tion in struc tions » These in stal la tion in struc tions are in tended for per sons with skills in elec tri cal and me chan i cal ar eas due to their train ing, ex - pe ri ence and re ceived in struc tions.
SSP 5 In stall the equip ment such that all parts are eas ily ac ces si - ble; this fa cil i tates main te nance and re pair work. 2.1. Trans port For trans port, only the ap pro pri ate lift ing gear should be used (e.g. fork lift or work shop crane).
SSP 5 2.2. Set-up The ar range ment of the hop per load ers may vary de pend ing on the type of de - vice to be con veyed on and the ma te rial used. Fas ten ing onto fixed ma chine throats is pro vided by means of strap re tain ers.
SSP 5 2.3. Com pressed-air sup ply For op er at ing the con trol valves and the clean ing unit, a com pressed-air sup ply is nec es sary. Depressurize com pressed-air sup ply lines which must be opened.
SSP 5 2.4. Elec tri cal con nec tion » The elec tri cal con nec tion may only be car ried out by trained per - son nel. Other per sons are not per mit ted to carry out the elec tri cal con - nec tion.
SSP 5 3. Func tional de scrip tion » This func tional de scrip tion is in tended for all op er at ing per son - nel of the equip ment. Pre req ui site for this func tional de scrip tion is gen eral knowl edge of con vey ing units.
SSP 5 3.1. Gen eral The con veyor hop per is used for the au to matic con vey ance of freely flow ing plas - tic gran ules, regrind and pow der. The hop per can only func tion in con nec tion with a multi-sta tion vac uum con vey ing sys tem.
SSP 5 3.2. Con trol ler SSP The set ting for the con vey ing time and the line clear time are made via the keys (A1: “change-over” key, A2: “ar row key”) on the front of the con trol sys tem. The val ues which have been set will be dis played on the dis play (B).
SSP 5 4. Putting into op er a tion » This chap ter is in tended for op er at ing per son nel. Pre req ui site for this chap ter is gen eral knowl edge of the op er a - tion of con vey ing units.
SSP 5 4.1. Set ting the con trol ler SSP It is only pos si ble to set the pulse du ra tion / time in ter val when the unit is not con vey ing any ma te rial.
SSP 5 4.2. Alarm Mes sages dis played on the con trol ler SSP If a dis tur bance oc curs in the unit, an alarm mes sage will be is sued. An “E” ap pears in the dis play and an er ror num ber.
SSP 5 5. Main te nance » This chap ter is in tended for per sons with skills in elec tri cal and me chan i cal ar eas due to their train ing, ex pe ri ence and re ceived in struc tions.
Page 23
SSP 5 Dis con nect the equip ment from mains sup ply be fore start ing main te nance pro ce dures to en sure that it can not be switched on un in ten tion ally. Depressurize all com pressed air pip ing of the equip ment be - fore start ing main te nance work.
SSP 5 5.1. Main te nance in ter vals Daily: check warn ing signs on equip ment for good leg i bil ity and com plete ness. Weekly: check the main te nance unit check the op er at ing pres sure in the fac tory ductwork sys tem (max.
SSP 5 5.2. Re placing the nonreturn valve seal ing ring » Stop the con vey ing pro ce dure. Switch off the hop per by means of the on/off switch on the con - nec tion hous ing. Switch off the con vey ing con trol by means of the main switch.
SSP 5 5.3. Re placing the out let flap seal ing ring » Stop the con vey ing pro ce dure. Switch off the hop per by means of the on/off switch on the con - nec tion hous ing.
SSP 5 5.3.1. Ad just the flap switch Re move the con nect ing plug “flap switch” from the con nec tion hous ing of the hop per. Con nect an ohm me ter to PINS 2 and 3 of the con nect ing plug “flap switch”.
SSP 5 5.4. Cleaning the hop per loader » Stop the con vey ing pro ce dure. Switch off the hop per by means of the on/off switch on the con - nec tion hous ing. Switch off the con vey ing con trol by means of the main switch.
SSP 5 5.5. Cleaning/re plac ing the fil ter car tridges of the clean ing unit » Stop the con vey ing pro ce dure. Switch off the hop per by means of the on/off switch on the con - nec tion hous ing.
Page 30
SSP 5 Re moval Open the ten sion ring (A). Re move the hop per loader lid. Re move the clean ing unit. Re lease clamp ing de vices of the fil ter car - tridges. Re move the fil ter car tridges from the in ter - me di ate plat form.
Page 31
15 l (0.53 cf.) • Typ i cal con vey ing ca pac ity SSP 5: up to 250 kg/hr (550 lbs/hr) with ex ten sion mod ule: 400 kg/hr (880 lbs/hr) Op tional Fea tures •...
Page 32
SSP 5 Di men sion Sheet Di men sions and data wit hout ob li ga ti on. Di men sions in mm (in.). Spec i fi ca tions may be sub ject to al te ra tions. Tech ni cal data 31...
Page 33
SSP 5 7. Spare parts list » This parts list is only for the use of trained per son nel only. All other per sons are not per mit ted to re pair or to change the equip ment. Spare parts list 32...
Page 34
SSP 5 Spare parts list 33 Download from Www.Somanuals.com. All Manuals Search And Download.
Page 35
SSP 5 Pos. Or der no. Des ig na tion 26487 Pneu matic valve 85460 Vent valve 85462 Com pressed-air con tainer 97556 So le noid valve 86851 Ten sion ring 98754 Sealing (1 m) 83081 Con trol ler SSP (24 V)
Page 37
Free Manuals Download Website h p://myh66.com h p://usermanuals.us h p://www.somanuals.com h p://www.4manuals.cc h p://www.manual-lib.com h p://www.404manual.com h p://www.luxmanual.com h p://aubethermostatmanual.com Golf course search by state h p://golfingnear.com Email search by domain h p://emailbydomain.com Auto manuals search h p://auto.somanuals.com TV manuals search h p://tv.somanuals.com...
Need help?
Do you have a question about the SSP 5 and is the answer not in the manual?
Questions and answers