    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Table of Contents TABLE OF CONTENTS 1. WARNINGS 1.1 G ENERAL 1.2 I NSTALLATION AND SAFETY INSTRUCTIONS 2. COMPONENT'S OVERVIEW 3. SOFTWARE DOWNLOAD & INSTALLATION 4.
  • Page 3 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3 S YSTEM ALIBRATION 7.3.1 L OGIN 7.3.2 I NSTALLATION SITE 7.3.3 V EHICLE SELECTION 7.3.4 C ONNECTION TO 7.3.5 V EHICLE INFORMATION 7.3.6 P ROFILE SELECTION 7.3.7 A...
  • Page 4: Warnings

    ‘urgent’ the warning. Mobileye 8 Connect is not an automated driving system. It does not replace the driver nor allow the driver to be any less vigilant or alert to the road than he/she would otherwise be.
  • Page 5: Installation And Safety Instructions

     Do not transfer Mobileye 8 Connect to another vehicle after installation.  The Mobileye 8 Connect GSM Nano SIM card will work only with the Mobileye 8 Connect unit with which it is supplied; do not use the SIM for other purposes or with other Mobileye 8 Connect units.
  • Page 6: Component's Overview

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 2. Component's overview Package List Component Mobileye P/N Master Camera unit ASY0000000000805 display unit – ASY000130 EyeWatch Main cable CAB000400 Rev3.3 GPS Cable & Module...
  • Page 7 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Installer Kit used for system EyeNET installation, calibration, EyeNET0001 and configuration used for both the main camera attachment to TACS00003 windshield (reference point) and for calibration...
  • Page 8: Software Download & Installation

    WWW.MOBILEYE.COM 3. Software download & installation Mobileye 8 Connect series uses a dedicated applications for configuration and calibration*. The applications are part of the Mobileye Installation Center. The software installer is available in our website under "support" tab or in the following direct link: https://www.mobileye.com/support/...
  • Page 9: Connection Scheme

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 4. Connection Scheme CAN-bus installation scheme Mix installation scheme (Analog + CAN-bus) Page 9 of 61 Technical Installation Guide (3G) v2.2...
  • Page 10: Analog Installation Scheme

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Analog installation scheme Page 10 of 61 Technical Installation Guide (3G) v2.2...
  • Page 11: Connection Description

    Table 1: Mobileye 8 Connect cable connections Mobileye 8 Connect signals cable (CAB000371 Rev6.3) The Mobileye 8 Connect signals cable splits into a few cables which connect to the vehicle power source, to the vehicle CAN-bus (Via CAN Reader connector) , to the vehicle analog speed signal, to the vehicle high-beams (for IHC), to one of the vehicle’s analog signals if...
  • Page 12 Green 4pin EyeWatch 3 RS-485 Low White 4pin EyeWatch 3 RS-485 GND Black 4pin EyeWatch 3 RS-485 5V DC 4pin EyeWatch 3 Table 2: Mobileye 8 Connect analog signals cable connection Page 12 of 61 Technical Installation Guide (3G) v2.2...
  • Page 13: Ferrite

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Ferrite Ferrite for power sources – Model 1 (ITM000777) Note: The Ferrite size and shape may vary different between different Ferrite models. 5.4.1 Instructions for Power Sources (CAB000371) Please follow the instructions bellow for the two ferrites installation: 1.
  • Page 14: Instructions For Power Sources

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Ferrite for power sources– Model 2 (ITM000786) Note: The Ferrite size and shape may vary different between different Ferrite models. 5.5.1 Instructions for Power Sources (CAB000371) Please follow the instructions bellow for the two ferrites installation: 1.
  • Page 15: Can Reader - (Cab000302)

    Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM EyeWatch – display and control unit (CAB000087) The EyeWatch is connected to the Mobileye 8 Connect EyeWatch female connector (J1) using the EyeWatch connecting cable male connector (J1). Table 3: EyeWatch connections Wire name...
  • Page 16: Eyenet - (Eyenet0001 / Cab000613)

    Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM EyeNET – (EYENET0001 / CAB000613) The Mobileye 8 Connect service port female connector (P2) is used to connect to the Mobileye EyeNET short cable male connector labeled “MOBILEYE8 SIDE” (J5). Wire name Wire color...
  • Page 17: Guidelines

    ACC (Accessory) position or ignition ON. Make sure the car headlights and/or any other power consuming devices/applications, e.g. air conditioning, are turned off during Mobileye 8 Connect installation to prevent battery drainage. Please ensure to identify the Mobileye 8 Connect cables according to table below. Identified vehicle’s signals Wires label...
  • Page 18: Installing The Eyewatch

    4. Remove the transparent protecting covering from the display surface 5. Insert the EyeWatch cable (CAB000087) behind the vehicle trimmings so that it reaches the EyeWatch connector of the Mobileye 8 Connect cable (CAB000400) Page 18 of 61 Technical Installation Guide (3G) v2.2...
  • Page 19: Installing The Mobileye 8 C

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Installing the Mobileye 8 Connect main unit (camera) NOTE Selecting the optimal location for the main unit is critical and can affect system performance.
  • Page 20 Connect cable (CAB000400) behind the vehicle trimmings so that it reaches all vehicle signals (it is recommended that you hang the Mobileye 8 Connect main unit on the rear-view mirror or place it on the dashboard before passing the cable behind the vehicle trimmings).
  • Page 21: Installation & Calibration Procedure

    7. Installation & Calibration procedure Removing unit’s back cover As part of the Mobileye 8 Connect calibration process, the camera angle must be adjusted as outlined below. To access the camera angle adjustment`s screw you must remove the main unit’s back cover.
  • Page 22: Communication / Connection Phase

    Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Communication / connection phase Mobileye 8 Connect service port interface is used to communicate with the Mobileye system. The EyeNET adapter enables fast connection between the Mobileye 8 Connect and Mobileye software running on a computer for system calibration and configuration.
  • Page 23: System Calibration

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM System Calibration 7.3.1 Login Open the Installation Center application on your computer and login using your personal login details youremail@email.com → Click "Login" to con nue...
  • Page 24: Installation Site

    It is possible to continue and open the IC Wizard application directly from the vehicle database.  If you are already connected to a Mobileye 8 Connect system and have completed the physical connections, you may skip the "vehicle database" and click the "wizard" button to immediately start the installation Page 24 of 61 Technical Installation Guide (3G) v2.2...
  • Page 25 WWW.MOBILEYE.COM NOTE When clicking the "Wizard" button you must be physically connected to a Mobileye 8 Connect system and the system power must be on to continue the calibration process. You will have an option to browse and choose the correct profile of the vehicle you are installing during a standard Wizard run as well.
  • Page 26: Vehicle Selection

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.3 Vehicle selection Choose the correct vehicle profile from the vehicle database. The Mobileye vehicle database contain CAN information such as: available signals, CAN-bus wires location, bus speed, CAN-bus wires colors or pin number if available and pictures of the vehicle &...
  • Page 27: Connection To See Q

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.4 Connection to SeeQ The app will check: communication status with Mobileye’s system and provide system information such as:  Connection status  System serial number ...
  • Page 28: Vehicle Information

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.5 Vehicle information Enter the license number, VIN number and choose the country from the dropdown menu. → Click "Next" to con nue Page 28 of 61...
  • Page 29: Profile Selection

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.6 Profile selection The software will remember and display all the vehicle and profile information you chose earlier. You can always choose a new profile or modify your earlier selection at this time.
  • Page 30: Analog Installation

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.7 Analog installation In a case you install the unit in vehicle which speed is not available by CAN, please locate the VSS signal in the vehicle, choose the most similar vehicle profile from the vehicle DB and change the Speed input from "Digital"...
  • Page 31: Signal Test

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.8 Signal Test Verify that all signals are detected by the Mobileye system. Activate each signal and an icon will be shown when it is detected by the Mobileye system.
  • Page 32: Signal Test Troubleshooting

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.8.1 Signal Test Troubleshooting: If the signals test failed in all or some of the inputs, please follow the next steps and press “reset test”:...
  • Page 33: Calibration

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.9 Calibration 7.3.9.1 Step 1 – TAC assembly Place the TAC target in front of & exactly at the center of the vehicle. When TAC is assembled and open correctly the bottom part of the checkered board TAC should be 90 cm from ground or 165 cm if the TAC is opened and flipped to high level (depending on the camera height).
  • Page 34: Step 2 - Camera Attachment

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.9.2 Step 2 – Camera attachment Use the surface cleaner supplied in the kit to clean the attachment area of the windshield and then use a dry paper towel to dry the area and remove residue before attaching the camera.
  • Page 35: Step 3 - Gps Attachment

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Deviation Offset Optimal- center of the windshield, if center not possible, according to the vehicle width: a. If the vehicle width measurement is up to 1.67 meters- camera can be attached up to 10cm from the windshield center MAX.
  • Page 36 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM GPS Attachment location allowed areas Angled Windshield: GPS attachment location allowed Green – – GPS attachment location not allowed Flat Windshield: GPS attachment location allowed Green –...
  • Page 37: Step 4 - Measurements

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.9.4 Step 4 – measurements NOTE Entering any measurement that is not in the acceptable range or not in the correct format will be highlighted in red and will not let you continue to the next step Enter each vehicle measurement in the correct field: ...
  • Page 38 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM  Distance to bumper (the distance from the camera to the front bumper). Measure the horizontal distance from the camera lens to the vehicle’s front bumper edge.
  • Page 39 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM  Distance to left, distance to right (the camera distance from the left and right windshield edge). Measure the lateral distance from the camera lens to both left & right windshield edges.
  • Page 40 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM  GPS Measurements (the GPS location) In this section, measure the exact GPS location on the Windshield. GPS to Bumper measurement: Measure the horizontal distance from the GPS unit to the vehicle’s front bumper edge (Distance to Bumper)
  • Page 41: Step 5 - Camera Angel Adjustment

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM GPS Height measurement- Measure the exact GPS height from to ground. NOTE If the GPS measurements will be incorrect, the ME8 data will be useless and the installer will have to go back and set the correct measurements.
  • Page 42: Step 6 - Car Hood

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 7.3.9.6 Step 6 – Car hood Drag the scroll bar on the left side of the image to adjust the blue field and prevent the camera from ‘seeing’...
  • Page 43 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Close TAC Place the TAC exactly in the center of the vehicle and close to the vehicle bumper. Press “Close TAC” for close TAC calculation.
  • Page 44 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Press “Far TAC” for far TAC calculation. Step 9 – calibration results Calibration results should meet the minimum requirements as follows: 1. FOE X optimal value is 0 ±15...
  • Page 45: Validation

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 8. Validation General Upon completion of the system calibration, the installer MUST validate all peripherals are functional and valid using the new validation tool which can be found as part of Mobileye IC prior to releasing the vehicle after the installation.
  • Page 46 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM The tool will check communication with the system and display the system s/n and FW version following by the peripherals test and display the status of each component.
  • Page 47 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Note that due to the installation location such as underground parking or indoor garage and GPS signal or cellular network is not available, the test status of the relevant component will pass but no valid data will be displayed.
  • Page 48: Appendix A - Can Reader

    9. Appendix A - CAN Reader Mobileye 8 Connect CAN Reader cable (CAB000302) The Mobileye 8 Connect CAN-Reader is a new, non-intrusive solution for CAN-bus connection. No more wrong connections, warranty violations or liability issues. The Mobileye CAN-Reader will allow you to better handle a CAN-bus reading by simply placing the Mobileye CAN-sensor on the vehicle CAN-bus wires without any wire cutting or pinching.
  • Page 49: Technical Spec

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Note: In some cases (if Er-20 shows on the EyeWatch display), you will need to switch between CAN High and CAN Low wires Technical Spec...
  • Page 50: Appendix B - Up/Down Configuration

    WWW.MOBILEYE.COM 10. Appendix B – up/down configuration Mobileye 8 Connect is based on a smart camera, which is installed on the vehicle’s front windshield. To suit all vehicle models (cars, trucks, buses) the smart camera main cable has two configurations: up and down.
  • Page 51 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Using a Philips screwdriver, unscrew the 3 screws and remove the main back cover ② Using a Philips screwdriver, unscrew to remove the main chassis from the frame ③...
  • Page 52 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM gently remove the chassis from the frame ④ Note: Do not unscrew the upper left and lower right screws. This will void the warranty! Remove the main cable connector and connect it to the desired configuration ⑤...
  • Page 53: Appendix C - Eyenet Holder (Asy000451)

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 11. Appendix C – EyeNET Holder (ASY000451) The EyeNET holder used to hold the EyeNET and maintain a stable communication with the Mobileye system.
  • Page 54 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Use to 2x screws to hold the EyeNET Route the EyeNET flat cable trough the designated gap and connect it in both ends to the Mobileye system...
  • Page 55: Appendix D - Calibration Tool

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 12. Appendix D – Calibration Tool The Calibration Tool allows to recalibrate the ME8 units without deactivation vehicle profile change such as windshield replacement.
  • Page 56 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 2. The tool will check communication with the system and display the system s/n and FW version and display the status of each component.
  • Page 57: Troubleshooting

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 3. The camera attachment, measurements and calibration slide will show. To attach, measure and calibrate, please refer to pages 32-42. 13. Troubleshooting 13.1 Troubleshooting 1.
  • Page 58 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM  The calculated camera height difference between what you measured and entered to the system may be up to 3cm.  If the roll value is more than 2°, make sure that the vehicle calibration surface is flat, and the main camera unit attachment is not rolled.
  • Page 59: Technical Specification

    Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM 14. Technical specification Mobileye® 8 Connect™ | Technical Specification Sheet (3G) Mobileye® 8 Connect Main Unit Physical Characteristics Full System Electrical Characteristics Length: 120mm...
  • Page 60 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Mobileye® 8 connect™ - 3G | Display unit Specification Sheet EyeWatch Display Unit Physical Characteristics EyeWatch 3 Diameter: 49mm Depth: 24mm Leg closed: 29mm...
  • Page 61 Mobileye 8 Connect | February 2022 MOBILEYE, AN INTEL COMPANY Technical Installation Guide (3G) v2.2 WWW.MOBILEYE.COM Mobileye® 8 Connect™ 3G Cellular Module | Technical Specification 3G Cellular Module Specification Model uBlox SARA-G3 GSM / GRPS protocol 3.75G HSPA Coverage area:...

Table of Contents