Rainfresh SST Assembly And Operation Instructions Manual

Drinking water system 1

Advertisement

Available languages

Available languages

Quick Links

Thank you for purchasing a Rainfresh Product. We are committed to ensuring that you are totally satisfied.
For any questions, please contact customer service.
Customer Service • 001 (905) 884 9388
Canada Toll Free • 1800 667 8072 (Mon to Fri 8:30 AM to 5:00 PM EST)
E-Mail: customersupport@rainfresh.ca • Web: www.rainfresh.ca
CONTENTS
A. Introduction
B. Safety Instructions
C. Technical Specifications
D. Installation
1.
Mounting the faucet
2.
Assembling & Mounting the unit
3.
Installing supply Fitting
4.
Start-up
E. Maintenance
1.
Ceramic cleaning & replacing
F. Troubleshooting
G. Parts List
H. Warranty
Tested and Certified by CSA Group to CSA Standard B483.1, to NSF/ANSI Standard 53 for reduction of
Cyst (e.g. Cryptosporidium & Giardia) to NSF/ANSI Standard 42 for reduction of chlorine, taste & odour,
and to NSF/ANSI 372 for lead-free requirements.
The standards referenced above evaluate products for use with disinfected waters.
Additional testing and verification for reduction of bacteria and particulates performed
by independent laboratory.
(Please read carefully before proceeding and retain for future reference)
2
2
2
3
3
4
5
6
6
6
7
8
8
Drinking Water System 1 • Model SST
Assembly and Operation Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SST and is the answer not in the manual?

Questions and answers

Summary of Contents for Rainfresh SST

  • Page 1 Assembly and Operation Instructions (Please read carefully before proceeding and retain for future reference) Thank you for purchasing a Rainfresh Product. We are committed to ensuring that you are totally satisfied. For any questions, please contact customer service. Customer Service • 001 (905) 884 9388 Canada Toll Free •...
  • Page 2 • This system is intended for use with cold water only. DO NOT INSTALL ON HOT WATER. Only use Rainfresh ceramic filter cartridge (model 1S) with this unit. No other filter cartridge will function with this system. • • Do not lubricate O-rings or seals with petroleum based lubricants. Only food-grade silicone (Dow 111 compound) should be used sparingly.
  • Page 3 Unpacking The Unit - The following items are included in the box: PACKING LIST 701-0 1x Escutcheon plate (730-2) Faucet Gauge Scrub Pad Supply fitting 1x Escutcheon (730-0) (703-4) (811-0) (2557-1) washer - Large 700-0 (730-3) 1x Washer - small 1x Washer - metal (730-4) Case (700-0)
  • Page 4 Use the 2557-1 supply fitting if the water supply pipe under the sink attaches to a 3/8” flex pipe from the kitchen faucet. If your piping is different or if you do not have a shut-off valve under the sink, you can order Rainfresh CKT14 or CK514 valves 1/4"...
  • Page 5 TUBE CONNECTS TO FILTER INLET Turn off the cold water Using a wrench, unscrew the Thread in the 2557-1 supply Push the RED tubing into the supply valve to the kitchen faucet tube from the supply adapter & then attach the supply adapter until it faucet.
  • Page 6 Ceramic cartridge is Replace cartridge immediately. Broken or cracked cartridges are not under warranty cracked or broken If the water from the SST system tests positive for bacteria: Bad water test • Inspect ceramic cartridge for cracks or breakage. Replace if necessary.
  • Page 7 Company and provided that only approved Envirogard/ Rainfresh replacement cartridge has been used in the housings. This warranty does NOT apply to the replacement cartridge which, by nature, will diminish in per- formance through normal use and requires regular replacement.
  • Page 8: Table Of Contents

    MANUEL UTILISATEUR (Please read carefully before proceeding and retain for future reference) Merci d'avoir acheté un produit Rainfresh. Nous nous engageons à vous donner entière satisfaction. Si vous avez des questions veuillez nous contacter. Assistance-clients • 001 (905) 884 9388 Région de Toronto •...
  • Page 9: Introduction

    • Ce système est destiné à être utilisé uniquement avec de l’eau froide. NE PAS L’INSTALLER POUR L’EAU CHAUDE. Utilisez uniquement des cartouche filtrantes Rainfresh cartouche filtrante en céramique (modèle 1S) avec ce dispositif. Aucune • autre cartouche filtrante ne fonctionnera avec ce dispositif.
  • Page 10: Assemblage Et Montage De L'unité

    Déballage de l'unité - Les éléments suivants sont inclus dans la boîte: LISTE DE COLISAGE 701-0 1x Plaque d'écusson (730-2) Robinet Jauge de Tampon abrasif Raccord 1x Rondelle (730-0) (811-0) cartouche d'écusson - grande d'alimentation 700-0 (703-4) (2557-1) (730-3) 1x Rondelle - petit 1x Rondelle - métal (730-4) Carter (700-0)
  • Page 11 Utilisez le raccord d'alimentation 2557-1 si le tuyau d'alimentation en eau sous l'évier se fixe à un tuyau flexible de 3/8 po du robinet de cuisine. Si votre tuyauterie est différente ou si vous n'avez pas de vanne d'arrêt sous l'évier, vous pouvez commander les vannes Rainfresh 1/4"...
  • Page 12: Démarrage

    TUBE CONNECTS TO FILTER INLET 1. Fermez la vanne 2. À l'aide d'une clé, dévissez 3. Enfilez l'adaptateur 4. Poussez le tube rouge dans d'alimentation en eau froide le tube du robinet de la d'alimentation 2557-1, puis l'adaptateur jusqu'à ce qu'il du robinet de cuisine.
  • Page 13: Garantie

    Détection de la Si l'eau du système SST est testée positive pour les bactéries: mauvaise qualité de Inspectez la cartouche en céramique pour des fissures ou des bris. Remplacez si nécessaire. l’eau Vérifier le diamètre de la cartouche à l'aide de la jauge (703-4) Fuite d'eau par •...
  • Page 14 à réparer ou à remplacer (à sa discrétion) toute pièce qu’elle juge défectueuse, pourvu qu’elle ne détermine pas que le filtre a été modifié ou qu’il a été utilisé incorrectement ou de façon abusive, et pourvu que seules des cartouche Rainfresh aient été utilisées dans le filtre. Cette garantie ne couvre pas les cartouches de rechange.