Rainfresh RO450 Installation And User Manual

Rainfresh RO450 Installation And User Manual

Reverse osmosis drinking water system
Table of Contents

Advertisement

Available languages

Available languages

REVERSE OSMOSIS DRINKING WATER SYSTEM
(MODEL RO450)
INSTALLATION AND USER MANUAL
We are committed to ensuring that you are totally satisfied.
If you have any problems, don't go back to the store - please contact us !
QUESTIONS
A. Introduction .................................................... 3
B. Safety Instructions .......................................... 3
C. Technical specifications .................................. 3
D. Water Quality Parameters .............................. 4
E. Installation ...................................................... 4
Install air-gap faucet .......................... 6
Make drain connection...................... 6
Mounting the main unit .................... 6
d.
Install RO Membrane......................... 7
Install supply valve ............................ 7
f.
Connect storage tank ........................ 8
g.
Start-up .............................................. 8
F. Maintenance ....................................... .............. 9
G. Troubleshooting ............................................ 11
H. Parts list .......................................................... 12
I. Warranty ........................................................ 12
Tested and Certified by CSA Group to CSA Standard B483.1, to
NSF/ANSI Standard 58 for reduction of Total Dissolved Solids (TDS)
and Sodium, and to NSF/ANSI 372 for lead-free requirements
Additional testing and verification for reduction of Barium, Cadmium, Chromium, Copper,
Cysts (e.g. Cryptosporidium & Giardia), Fluoride, Lead, Mercury, Nitrates and Chlorine
performed by independent laboratory. Claims not performance certified by CSA Group.
Thank you for purchasing a Rainfresh Water Filter.
Most issues can be resolved over the phone
Canada Toll Free
1800 667 8072
Toronto and Area
(905) 884 9388
(Mon to Fri
8:30 AM to 5:00 PM EST)
CONTENTS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RO450 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rainfresh RO450

  • Page 1: Table Of Contents

    (MODEL RO450) INSTALLATION AND USER MANUAL Thank you for purchasing a Rainfresh Water Filter. We are committed to ensuring that you are totally satisfied. If you have any problems, don’t go back to the store – please contact us !
  • Page 2 DO NOT RETURN TO STORE Need Help? Call toll free at: 1-800-667-8072 Mon – Fri 8:30 AM – 5:00 PM EST Assistance is available for:  Missing parts  Installation, operation or maintenance or any other questions about your new system NOTES Once unit is installed, it may take up to 5 hours before ...
  • Page 3: Introduction

    Lead, Mercury, Nitrates, Sodium, TDS, Chlorine, Taste and Odour. It also traps >99.95% cysts (Cryptosporidium & Giardia) greater than 99.95% and filters sediment, silt and rust. Water produced by the Rainfresh RO system can be used for drinking, cooking, juices, beverages, watering plants, steam irons, humidifiers, aquariums etc.
  • Page 4: Water Quality Parameters

    Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. For effective disinfection we recommend Rainfresh Whole-house UV disinfection systems.
  • Page 5 Fig 1A shows a typical undersink installation Plan your installation – Typical Undersink Installation : Fig 1A Basement Installation The Reverse Osmosis system can also be installed in the basement with only Fig 1B the blue (filtered water) tube running to the faucet as shown in Fig 1B. This will require a hole through the basement ceiling and may not be possible in every situation.
  • Page 6: Install Air-Gap Faucet

    Fig 3A STEP 1 : Install Air-Gap Faucet (See Fig. 3) The faucet (2640) may be installed on the counter-top or the sink, as desired. For counter-top installation, position faucet on the counter-top beside the sink where it will not be obstructed from above or below. NOTE: The faucet has a 3/8”...
  • Page 7: Install Supply Valve

    b) Partially screw the two mounting screws (1011-0) into screw locations. NOTE: If wall is too thin to accept screws, use round-head nuts and bolts (not supplied) to mount bracket. Install pre-filters and membrane as per instructions below before mounting unit on the wall. c) Remove wrapping from sediment pre-filter (HP1) and push it into the head carefully.
  • Page 8 IMPORTANT: Before you install supply valve, confirm the cold water pipe by running hot water through your kitchen faucet. Touch both pipes under the sink to verify cold water pipe and turn off the faucet. Now turn off the water supply valve for the cold water pipe and open the cold water side of the kitchen faucet to release the pressure.
  • Page 9: Maintenance

    TDS reduction 1-4 years avg stores Head seals 2502 1 year Sump** 5 years Call Rainfresh or order Vent pin assembly 2505 5 years online at www.rainfreshstore.ca Other parts *Note: Cartridge life is directly dependant on water conditions and volume of water filtered. Excessive sediment may cause more frequent replacement.
  • Page 10 d) Unpack the new membrane and apply silicone lubricant on the two O-rings. Slide membrane into housing, "O" ring side first. Push membrane completely in until slotted end is flush with housing opening. If you cannot push the membrane fully in, pull it out and apply some more lubricant and repeat procedure. e) Replace housing cap.
  • Page 11: Troubleshooting

    (G) Troubleshooting Problem Reason(s) Solution Faucet makes Drain water running from unit. This is normal when RO is filling the storage tank gurgling noise 1. The feed water saddle valve may be closed. 1. Open feed water valve. Water does not 2.
  • Page 12: Parts List

    Company inspection to be defective, provided that the product has not been misused, abused, altered or damaged as determined by the Company and provided that only approved Enivrogard/Rainfresh replacement cartridges have been used in the housings. This warranty does NOT apply to the replacement cartridge(s) which by nature will diminish in performance through normal use and require(s) regular replacement.
  • Page 13 Manuel d'installation et d'utilisation Nous vous remercions d'avoir acheté un de nos systèmes de désinfection ENVIROGARD/Rainfresh. Nous nous engageons à vous donner entière satisfaction. Si l'article vous cause un problème, ne retournez pas au magasin. Appelez-nous ! La plupart des problèmes peuvent être résolus par téléphone...
  • Page 14 NE PAS RETOURNER AU MAGASIN Besoin d’aide pour? Appelez gratuitement au: 1-800-667-8072 Du lundi au vendredi de 8h30 à 17h00 HNE L’assistance east disponible pour:  Parties manquantes  Installation, utilisation ou maintenance ou toute autre question concernant votre nouveau système REMARQUES ...
  • Page 15: Introduction

    (Cryptosporidium et Giardia) supérieurs à 99,95% et filtre les sédiments, le limon et la rouille. L'eau produite par le système Rainfresh RO peut être utilisée pour la boisson, la cuisine, les jus de fruits, les boissons, l'arrosage des plantes, les fers à...
  • Page 16: Paramètres De Qualité De L'eau

    être utilisés avec de l'eau désinfectée pouvant contenir des kystes pouvant être filtrés. Pour une désinfection efficace, nous recommandons les systèmes de désinfection par UV Rainfresh Whole-house. Installez un régulateur de pression et un limiteur de coup de bélier si la pression dépasse la valeur nominale maximale à tout moment. Remarque: Si la pression diurne est supérieure à...
  • Page 17: Installation Du Robinet

    Planifiez votre installation - Installation typique sous l'évier Fig 1A Fig 1B Installation de sous-sol Le système d'osmose inverse peut également être installé dans le sous-sol avec seulement le tube bleu (eau filtrée) allant au robinet, comme indiqué sur la figure 1B. Cela nécessitera un trou dans le Bleu plafond du sous-sol et pourrait ne pas être possible dans toutes les situations.
  • Page 18 Fig 3A Étape 1 : Installation du robinet (Voir Fig. 3) Le robinet (2650-0) peut être installé sur le comptoir ou l’évier. S’il est installé sur le comptoir, assurez-vous qu’il n’y a aucune obstruction au- dessus ni en dessous.. REMARQUE: Le robinet a un tuyau de vidange noir de 3/8 ”et un tuyau de BLACK 2611-1 vidange gris de ¼”...
  • Page 19 b) Vissez partiellement les deux vis de fixation (1011-0) aux emplacements des vis. REMARQUE: Si le mur est trop fin pour accepter les vis, utilisez des écrous et des boulons à tête ronde (non fournis) pour monter le support. Installez les pré-filtres et la membrane selon les instructions ci-dessous avant de fixer l'unité...
  • Page 20 IMPORTANT: Avant d'installer la vanne d'alimentation, vérifiez le tuyau d'eau froide en faisant couler de l'eau chaude dans le robinet de votre cuisine. Touchez les deux tuyaux sous l'évier pour vérifier le tuyau d'eau froide et fermez le robinet. Maintenant, fermez la vanne d'alimentation en eau du tuyau d'eau froide et ouvrez le côté eau froide du robinet de la cuisine pour relâcher la pression.
  • Page 21 Réduction de TDS 1-4 ans en moyenne magasins de rénovation 2502 Un ans Joints de tête 5 ans Carter** En appelant Rainfresh ou en commandant en ligne Montage de la tige de 2505 5 ans ventilation sur le site Autres pièces www.rainfreshstore.ca...
  • Page 22 Remplacement de la membrane d’osmose inverse (ROM50) La membrane doit être remplacée lorsqu’il y a une augmentation de la teneur en minéraux dans l’eau filtrée ou qu’il n’y a presque plus d’eau qui sort du robinet. 1. Coupez l’alimentation en eau, fermez la valve du réservoir et ouvrez le robinet pour dépressuriser le système.
  • Page 23: Dépannage

    (G) Dépannage Problème Cause possible Solution Le robinet fait un Ce bruit est normal pendant que le système remplit bruit de L’eau rejetée coule dans le drain. le réservoir. gargouillement. 1. La valve à étrier est fermée. 1. Ouvrir la valve. 2.
  • Page 24: Liste Des Pièces

    à réparer ou à remplacer (à sa discrétion) toute pièce qu'elle juge défectueuse, pourvu qu'elle ne détermine pas que le filtre a été modifié ou qu'il a été utilisé incorrectement ou de façon abusive, et pourvu que seules des cartouches Rainfresh aient été utilisées dans le filtre.

Table of Contents