Schubert Price Cube Prime Box Pico PBI1100ED 044 00 Operating Instructions Manual

Advertisement

Quick Links

MODULARITY IS PRIME.
Prime Box Pico
PBI1100ED_044_00
PBI1100ED_044_01
Operating instructions
6902167 | V 1.02
US-English translation of the original German Operating instructions
This operating manual is part of the technical documentation.
It provides technicians and system managers with the necessary information on:
Installation
Installation and commissioning
Operation
Maintenance
Illustrations may differ.
www.schubert-system-elektronik.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Price Cube Prime Box Pico PBI1100ED 044 00 and is the answer not in the manual?

Questions and answers

Summary of Contents for Schubert Price Cube Prime Box Pico PBI1100ED 044 00

  • Page 1 6902167 | V 1.02 US-English translation of the original German Operating instructions This operating manual is part of the technical documentation. It provides technicians and system managers with the necessary information on: • Installation • Installation and commissioning • Operation • Maintenance www.schubert-system-elektronik.de...
  • Page 2 To be observed in general To be observed in general Safety instructions This document contains instructions that you must follow for your personal safety and to prevent damage to property. The instructions are marked by a warning triangle and are graded according to the degree of risk. Symbol with signal word: DANGER Imminent danger to life and health of persons.
  • Page 3 Products from Schubert System Elektronik GmbH comply with the relevant harmonized European standards (EN) for the respective area of application. Warranty The agreements stipulated in the General Terms and Conditions of Business (GTC) apply to Schubert System Elektronik GmbH equipment. Installation conditions The installation conditions and safety instructions specified in this document must be observed during the commission- ing and ongoing operation of the products.
  • Page 4 To be observed in general EU Declaration of Conformity The product from Schubert System Elektronik GmbH complies with the directives listed in the “Technische Daten” chapter. The requirements are assessed on the basis of the standards listed therein. The EU Declaration of Conformity and the associated documentation are provided in accordance with the directives at:...
  • Page 5: Table Of Contents

    Table of contents Table of contents Characteristic ............................... 1 Overview ................................. 1 Areas of application ..............................1 Block diagram ................................ 2 Installation ................................3 Unpacking and checking delivery contents ......................3 Storage and transport ............................3 Installation ................................3 Temperature ................................3 Ventilation ................................
  • Page 6 Table of figures Table of figures Fig. 1-1: Device view ..............................1 Fig. 1-2: Block diagram ..............................2 Fig. 2-1: Ventilation ................................. 4 Fig. 2-2: Installation and orientation options ........................5 Fig. 3-1: Opening the housing ............................8 Fig. 3-2: Connecting the 24 V DC supply voltage ......................9 Fig.
  • Page 7: Characteristic

    Characteristic Characteristic Overview The Prime Box Pico PBI1100ED_044 is designed as a modular box PC with high connectivity in a compact design for vertical installation in the control cabinet. Protection class: IP20 compliant with DIN EN60529 (not evaluated by UL) „...
  • Page 8: Block Diagram

    Characteristic Block diagram Fig. 1-2: Block diagram Prime Box Pico Operating instructions | V 1.02...
  • Page 9: Installation

    Installation Installation Unpacking and checking delivery contents Check packaging for transport damage. – – Carefully remove the packaging to avoid causing damage. Keep the original packaging for future transport. Keep the documents supplied. – Check the contents of the packaging for visible transport damage. Check the contents for completeness on the basis of the delivery bill.
  • Page 10: Ventilation

    Installation Ventilation Cooling concept „ • The processor is cooled purely passively via free convection, i.e. neither CPU nor system fans are used. • The CPU as well as all power semiconductors of the power supply are connected to the cover of the computer housing via heatspreaders.
  • Page 11: Installation Position And Mounting

    Installation 2.5.1 Installation position and mounting The Prime Box Pico PBI1100ED_044 is designed for vertical installation in control cabinets. Pay attention to the „ correct orientation during installation; do not install the device upside down - see illustration below. Installation in the control cabinet is carried out on the top-hat rail by means of a mounting bracket.
  • Page 12: Connection, Commissioning And Operation

    Connection, commissioning and operation Connection, commissioning and operation Establishing operational readiness Interference-free connections for trouble-free operation When connecting peripheral devices, use shielded bus and LAN cables with shielded connectors to meet EMC requirements. If possible, screw or lock the plug connections as this will improve electrical shielding Signal lines must not be routed in the same cable duct as power lines.
  • Page 13: Expanding The Prime Box Pico

    Never operate the Prime Box Pico with the housing open. – Preconditions The devices from Schubert System Elektronik GmbH feature peripheral interfaces that can be used to connect various components. When using commercially available peripheral devices (e.g. at the USB port), please note that their EMC interference immunity is often designed for office use.
  • Page 14: Opening And Closing The Device Again

    Connection, commissioning and operation Opening and closing the device again Damage to the device. To avoid damage to the device, perform the following before opening it: – Shut down the operating system. Disconnect the power supply. – Risk of burns from hot surfaces Heat sinks and heat pipes on the inside can still be very hot even after the device has been turned off: –...
  • Page 15: Connecting The Power Supply

    Connection, commissioning and operation Connecting the power supply Supply voltage 24 V DC Electric shock if unsuitable power supply is used. Connect the device only to a power supply that meets the requirements for safe ex- tra-low voltage (SELV/PELV) according to EN/UL 61010-2-201. Connect the device only to a power supply that meets the requirements for an ener- gy-limited circuit according to EN/UL 61010-2-201, chapter 9.4 or to a circuit that meets the requirements of NEC Class 2 according to UL 1310.
  • Page 16: Connecting Peripheral Devices

    Connection, commissioning and operation Connecting peripheral devices 3.5.1 Interfaces Access to connections and drives Connections to the peripherals are located on the front of the housing „ (see chapter “4 Technical data” on page 14). May include optional equipment! Fig. 3-3: Connections The connections are marked on the front cover.
  • Page 17: Prime Box Pico Setup/Operation

    Connection, commissioning and operation Prime Box Pico setup/operation 3.6.1 Operating system As ordered, Schubert System Elektronik GmbH installs the operating system specified in chapter “4 Technical data” on page 14. License notice: The pre-installed operating system is software in the Microsoft Embedded license model.
  • Page 18: Replacing The Buffer Battery

    Connection, commissioning and operation The Update function is completely disabled. „ This setting can be changed in the Policy Editor: Computer Configuration-> Administrative Templates -> Windows Components -> Windows Update: Configure Automatic Updates In addition, the Update service must be re-enabled: Open the command prompt with administrator rights and enter the following command: sc config „wuauserv“...
  • Page 19: Disposal

    Connection, commissioning and operation When the battery is replaced, the configuration data of the device is deleted. Take note of the current BIOS setup settings. Dispose of used batteries according to local regulations. May include optional equipment! Fig. 3-4: Disengaging the battery carrier and changing the buffer battery –...
  • Page 20: Technical Data

    Technical data Technical data General Component Description Housing Prime Box Pico Mechanically stable aluminum housing for vertical installation in the control cabinet Wall mounting or mounting on 35 mm top-hat rail (DIN EN50022 and EN50045) Passive cooling Industrial, EMC-compliant housing design Dimensions including heat sink and holder (WxHxD): 55 mm x 170 mm x 100.75 mm Weight: 1.15 kg...
  • Page 21: Mechanical Dimensions

    Technical data Mechanical dimensions 4.2.1 Device dimensions Prime Box Pico | PBI1100ED_044 11,00 44,00 92,25 8,50 Dimensions in mm General tolerance ISO 2768 – mK May include optional equipment! Fig. 4-1: Device dimensions Prime Box Pico Operating instructions | V 1.02...
  • Page 22 Doc. No.: 6902167 Operating instructions V 1.02 / 14. October 2021 © Schubert System Elektronik GmbH. All rights reserved and subject to change. All information is non-binding and does not constitute a warranty of characteristics. No liability is assumed for typographical errors.
  • Page 23: Annex | Grounding Concept

    Ground straps with ring cable lugs are not suitable. The grounding point must also have a low-impedance ground connection. „ Length, width and shape of the ground straps are recommendations of Schubert System Elektronik GmbH. „ Fig. A-2: Ground straps Grounding concept Annex | V 1.02...
  • Page 24: Fig. A-3: Grounding Concept - Monitor Pc

    Fig. A-4: Grounding to be avoided Annex: Grounding concept V 1.02 / 14. October 2021 © Schubert System Elektronik GmbH. All rights reserved and subject to change. All information is non-binding and does not constitute a warranty of characteristics. No liability is assumed for typographical errors.