Schubert Prime Cube Prime Panel Performance Attachment PPI1000AD 215 00 Operating Instructions Manual

Table of Contents

Advertisement

Quick Links

MODULARITY IS PRIME.
Prime Panel Performance Attachment
21.5"
PPI1000AD_215_00
PPI1000AD_215_01
Operating manual
6902172 | V 1.02
Translation of the German original operating manual
This operating manual is part of the technical documentation.
It provides technicians and system managers with the necessary information on:
Installation
Commissioning
Operation
Maintenance
www.schubert-system-elektronik.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Prime Cube Prime Panel Performance Attachment PPI1000AD 215 00 and is the answer not in the manual?

Questions and answers

Summary of Contents for Schubert Prime Cube Prime Panel Performance Attachment PPI1000AD 215 00

  • Page 1 6902172 | V 1.02 Translation of the German original operating manual This operating manual is part of the technical documentation. It provides technicians and system managers with the necessary information on: • Installation • Commissioning • Operation • Maintenance www.schubert-system-elektronik.de...
  • Page 2 General information General information Safety instructions This document contains instructions that you must follow for your personal safety and to prevent damage to property. The instructions are marked by warning triangles and are graded according to the degree of risk. Symbol with signal word: DANGER Imminent danger to the life and health of persons.
  • Page 3 Products from Schubert System Elektronik GmbH comply with the relevant harmonized European standards (EN) for the respective area of application. Warranty The agreements stipulated in the General Terms and Conditions of Business (GTC) apply to Schubert System Elektronik GmbH equipment. Safety instructions The safety instructions specified in this document must be observed during the commissioning and ongoing operation of the products.
  • Page 4 General information EU Declaration of Conformity The product from Schubert System Elektronik GmbH complies with the directives listed in the “Technische Daten” chapter. The requirements are assessed on the basis of the standards referenced therein. The EU Declaration of Conformity and the associated documentation are provided in accordance with the directives at:...
  • Page 5: Table Of Contents

    Table of contents Table of contents Characteristic ............................... 1 Overview ................................. 1 Areas of application ..............................1 Block diagram ................................ 2 Installation ................................3 Unpacking and checking delivery contents ......................3 Storage and transport ............................3 Temperature ................................3 Operation ................................3 Ventilation ................................
  • Page 6 Table of figures Table of figures Fig. 1-1: 21.5“ Prime Panel Performance Installation – view of device ................. 1 Fig. 1-2: Block diagram ..............................2 Fig. 2-1: Ventilation ................................. 4 Fig. 2-2: Permissible installation position ........................5 Fig. 2-3: Connection flange for support arm systems and stand systems ..............6 Fig.
  • Page 7: Characteristic

    Characteristic Characteristic Overview The Prime Panel Performance Attachment PCs are designed as industrial touchscreen computers for demanding appli- cations with high connectivity. The device is intended for the use in plant engineering; the back of the device housing is designed for mounting on a support arm system. Protection class: IP 65 all-round (not evaluated by UL) „...
  • Page 8: Block Diagram

    Characteristic Block diagram CFast Kartenleser PCIe x16 RP-SMA RP-SMA (optional) (optional) Touchcontroller M.2 SSD Funkschnittstellen PCIe Riser Karte (optional) verschiedene Größen 1x mPCIe Steckplatz DDR4-2666 2,5" SSD DDR4-2666 Ethernet Modul bis 16 GB bis 16 GB verschiedene Größen (optional bis 32 GB) (optional bis 32 GB) (optional) (optional)
  • Page 9: Installation

    Installation Installation Unpacking and checking delivery contents Check packaging for transport damage. – – Carefully remove the packaging to avoid causing damage. Keep the original packaging for future transport. Keep the documents that are included. – Check the contents of the packaging for visible transport damage. Check the contents for completeness on the basis of the delivery note.
  • Page 10: Ventilation

    Installation Ventilation Cooling concept „ • The processor uses only passive cooling via free convection, i.e. there are neither CPU fans nor system fans. • The CPU as well as all power semiconductors of the power supply unit are connected to the cover of the com- puter housing via heat spreaders and heat pipes.
  • Page 11: Installation Position And Mounting

    Installation 2.5.1 Installation position and mounting The device is designed for horizontal installation (connections at bottom) on a support arm system. Vertical installation as well as deviations of up to ±5° from the specified directions are permissible. If deviating from the vertical installation, make sure not to cause a heat build-up inside the housing. For dimensions, see chapter “4 Technical data”...
  • Page 12: Mounting And Sealing

    Installation 2.5.2 Mounting and sealing The device is suitable for the following: • Mounting on support arm systems and stand systems from various manufacturers using the flange connection at the back of the housing. The housing comes with four drill holes for mounting on the support arm as well as a cable pass-through opening.
  • Page 13: Fig. 2-4: Installing A Flange Adapter

    Installation – Open the housing as described in chapter “3.3.2 Opening the device”. Install the flange adapter properly on the connection flange at the rear of the computer housing. Make sure that the – flange seal is properly seated. Front-end Computer housing Flange adapter Flange seal,...
  • Page 14: Connection, Commissioning And Operation

    Connection, commissioning and operation Connection, commissioning and operation Establishing operational readiness Noise-immune connections for trouble-free operation When connecting peripheral devices, use shielded bus and LAN cables with shielded connectors to meet EMC requirements. If possible, screw or lock the plug connections as this will improve electrical shielding Signal lines must not run in the same cable duct as power lines.
  • Page 15: Expanding The Prime Panel Performance Installation

    Never operate the Prime Panel Performance Attachment with the housing open. – Preconditions The devices from Schubert System Elektronik GmbH feature peripheral interfaces that can be used to connect various components. When using commercially available peripheral devices (e.g. at the USB port), please note that their EMC interference immunity is often designed for office use.
  • Page 16: Opening And Closing The Device

    Connection, commissioning and operation Opening and closing the device 3.3.1 Parts of the housing Computer housing Front-end Hinge Glass front Cover (top) Heat sink Sealing EMC angle profile Interface plate Cover (bottom) Fig. 3-1: Parts of the housing The device consists of the front-end and the computer housing. These two components are hinged together, allowing the front-end to fold open to the side after four Torx screws have been removed.
  • Page 17: Opening The Device

    Connection, commissioning and operation 3.3.2 Opening the device Electrostatic discharge All assemblies and components are ESD sensitive. Always observe the information in “ESD information” on page 9. Damage to the device To avoid damage to the device, do the following before opening it: –...
  • Page 18: Closing The Device

    Connection, commissioning and operation 3.3.3 Closing the device Electrostatic discharge All assemblies and components are ESD sensitive. Always observe the information in “ESD information” on page 9. Damage to the device Always use a suitable soft, clean pad to set the device down on; otherwise, the display may get scratched.
  • Page 19: Connecting The Power Supply

    Connection, commissioning and operation Connecting the power supply Supply voltage 24 V DC Electric shock if unsuitable power supply is used. Connect the device only to a power supply that meets the requirements for safe ex- tra-low voltage (SELV) according to EN/UL 61010-2-201. Connect the device only to a 24 V DC power supply (18 ...
  • Page 20: Connecting Peripheral Devices

    Connection, commissioning and operation Connecting peripheral devices 3.5.1 Interfaces Access to connections and drives Connections with the periphery are located on the interface plate inside the device; they are only accessible after „ the device has been opened, and the cable connections must be run outside via the support arm system. For more details on the connections, see chapter “4 Technical data”...
  • Page 21: Setting Up And Operating The Device

    Setting up and operating the device 3.6.1 Operating system As ordered, Schubert System Elektronik GmbH installs the operating system specified in chapter “4 Technical data” on page 18. Licensing information for Windows IoT systems: The pre-installed operating system is software in the Microsoft Embedded license model.
  • Page 22: Replacing The Buffer Battery

    Connection, commissioning and operation 3.6.4 Replacing the buffer battery Electrostatic discharge All assemblies and components are ESD sensitive. Always observe the information in “ESD information” on page 9. The buffer battery is located on a battery carrier on the computer PCB. It is only accessible after the device has „...
  • Page 23: Disposal

    Connection, commissioning and operation Installing the buffer battery Electrostatic discharge All assemblies and components are ESD sensitive. Always observe the information in “ESD information” on page 9. Insert the new buffer battery into the socket with “+” facing upwards. To do this, first insert the buffer battery on the side opposite the clamp under the holders.
  • Page 24: Technical Data

    Technical data Technical data Prime Panel Performance Attachment 21.5" Component Description Model code PPI1000AD_215 Dimensions 538.6 x 330.1 x 129 mm Weight 12.5 kg Housing • Aluminum front frame, powder-coated • Aluminum rear panel, powder-coated • Aluminum computer core with heat sink, anodized •...
  • Page 25 Technical data Operating system • Windows 10 IoT Enterprise LTSC 2021 • LINUX 64bit: Debian 10 distribution Ambient • -10 °C to +45 °C with natural convection (up to +40 °C if using a HDD) temperature * • -10 °C to +50 °C** with air flow greater than 0.4 m/s (up to +45 °C if using a HDD) Storage temperature -20 °C to +60 °C Air humidity...
  • Page 26: Mechanical Dimensions

    Technical data Mechanical dimensions 4.2.1 Device dimensions 422,8 476,6 309,1 330,1 165,1 21,1 Dimensions in mm, not in scale General Tolerance ISO 2768 - mK Fig. 4-1: 21.5“ Prime Panel Performance Attachment - device dimensions Prime Panel Performance Attachment | 21.5" Operating manual | V 1.02...
  • Page 27 Technical data Prime Panel Performance Attachment | 21.5" Operating manual | V 1.02...
  • Page 28 Doc. No.: 6902172 Operating manual V 1.02 / 13. April 2023 © Schubert System Elektronik GmbH. All rights reserved and subject to change. All information is non-binding and does not constitute a warranty of characteristics. No liability is assumed for typo- graphical errors.
  • Page 29: Annex | Grounding Concept

    Ground straps with ring cable lugs are not suitable. The grounding point must also have a low-impedance ground connection. „ Length, width and shape of the ground straps are recommendations of Schubert System Elektronik GmbH. „ Fig. A-2: Ground straps Grounding concept | Annex | V 1.02...
  • Page 30: Fig. A-3: Grounding Concept - Monitor Pc

    Fig. A-4: Grounding to be avoided Annex: Grounding concept V 1.02 / 13. April 2023 © Schubert System Elektronik GmbH. All rights reserved and subject to change. All information is non-binding and does not constitute a warranty of characteristics. No liability is assumed for typographical errors.

Table of Contents