3-1. SPECIFIC CONDITIONS OF USE: ................7 4. Specifications ......................8 5. Process Connection ....................10 5-1. SMT2001 ......................10 5-2. SMT2002 / SMT2003 .................... 10 6. Each Part Name and Working Principle ..............11 6-1. Each Part Name..................... 11 6-2.
Page 3
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 8-3. Explosion Proof Certification Information .............. 15 9. HART® Communication ..................16 9-1. Electrical Connection Diagram (Using the HART® Protocol) ........16 9-2. 2-Wire (Current) HART® System................16 10. Error code ......................17 11. Wiring........................17 11-1.
3) This manual is part of the product and should be kept in the vicinity of the product installation site so that it can be checked by the operator at all times. 4) WISE Control Inc. All product, product specifications and data are subject to change without notice to improve reliability, function or design or otherwise.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Safety Instructions 2.1 Warning Notices ! NOTE. Operational safety information for users to avoid dangerous situations. 2.2 Qualification of Personnel It is recommended that installation, test runs, operation, maintenance, disposal and disposal be carried out by suitably qualified professionals. We recommend that work on electrical components be carried out by a qualified electrician and must be carried out in accordance with relevant regulations and guidelines.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2.5 Installation and Safety Instructions In case of increased danger of a lightning strike or damage by overvoltage, more robust lightning ● protection equipment should be used. Excessive dust accumulations (over 5 mm) or complete coverage with dust must be prevented! ●...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 11 Avoid any mechanical force greater than allowed pressure to the device connector, it could change the characteristic of the device or cause the damage so requires a special care. This applies particularly to very small pressure ranges products. 12 In the case of hydraulic systems, orient the device so that the pressure connector faces upwards (for venting).
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2.7 Orientation of the Display Module The display can be rotated in 90-degree increments, making it easy to view from any position. To change the display orientation, proceed as follows: Fully tighten the cover lock bolt to open the front cover. Open the front cover.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Specifications 1. SMT200x series 2. Power: 24 V DC (12~42 V DC) 3. Output: 4~20mA with HART® Protocol 4. Explosion Proof: 4.1 ATEX, IECEx Flameproof enclosures Ex db IIC T4 / T5 / T6 Gb Ex tb IIIC T80°C / T90°C / T130°C Db Ta = -40°C to +60 °C ATEX Cert.: CML 17ATEX1235X...
Page 10
8. Process Material: Gas, Steam and Liquid 9. Accuracy: Full scale of ± 0.05 % / Full scale of ± 0.075 % 10. Measuring range: SMT2001: 1~10 mbar to 0.3~30 bar SMT2002: 6~60 mbar to 4~400 bar SMT2003: 20~400 mbar to 0.3~30 bar 11.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Each Part Name and Working Principle 6-1. Each Part Name 6-2. Principle of operation 1. Pressure is transmitted from the pressure input unit through the diaphragm. 2. The sensor detects the amount of physical displacement occurring in the diaphragm due to the transmitted pressure.
Configuration of the device can be carried out with the aid of a HART® communication device. WISE CONTROL Inc. recommends a communicator by licensed HART® for this purpose. In order to ensure trouble-free operation, the following specifications should be taken into account: Maximum length of cable between measuring instrument and supply unit: 9-1.
08XX: Sensing part Error 10XX: Display board Error ####: Pressure out of range If the above error code or other problems occur, please contact WISE. 11. Wiring NOTE. When using devices with connector terminals, implement connections such that the separation distances are in compliance with standards and connecting lines cannot become disconnected.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Note. The product must be connected according to the electrical specifications provided in the connection table and wiring diagram below. Connection Assignment Table: Electrical Connections Connection Terminals Supply + (Ub+) PWR + Supply / Test - (Ub-) (COM: PWR- /TEST- ) Test + TEST +...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 12. Electrical Connection Diagram 13. Trial Run 1) Before Trial Running the device, check that it has been properly installed, and make sure that it does not show any visible defects. 2) The device may be commissioned only by appropriately qualified and trained personnel who have read and understood the user manual.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 14. Operation Measured values on the displayed with up to Max.7-digit character string comprising letters and numbers. A bar graph is included on the display; This shows the acting pressure as a percentage of the measuring range.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 15. Local Button Manual 15-1. Configuration Process 1. Start by pressing and holding the Z+S buttons simultaneously for about 2 to 5 s. 2. Select the desired menu item using the Z+S buttons. 3. Invoke the selected menu item by pressing and holding the Z+S buttons simultaneously for about 2 to 5 s.
Page 23
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com So after invoking a menu item of this kind (ex. “DAMPING”), pressing the S button makes the first digit of the currently set value begin to flash. You can now use the Z button to adjust the desired digit.
Page 24
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Sets the End Value Use the Z and S buttons to set the end value for the measuring range, SET 100% and then confirm the value by pressing the Z and S buttons simultaneously for at least 2 - 5 seconds. The display shows "OK". Zeros the Display (In Physical Units (Zero Point Trim)) After setting and applying the reference pressure, press the Z and S SHIFT ZERO...
Page 25
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Button Lock(Lo) / Unlock(unLo) Setting In the LOCK menu, set unLo(unlock) / Lo(lock) and press and hold the Z + S button simultaneously for 2 to 5 seconds to save the setting and LOCK display. The display then indicates “OK”. ※...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 17. FLOW UNIT Quantity of Flow (Volumetric flow) m³/s Cubic meter per second m³/m Cubic meter per minute m³/h Cubic meter per hour m³/d Cubic meter per day Liter per second Liter per minute Liter per hour ft³/s Cubic feet per second ft³/m...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 18. Decommissioning Never disassemble the product while it is connected to a power source or in a hazardous area. Before disassembling the product, be sure to turn off the power and discharge the residual pressure and residual fluid. Before discharging, check the direction in which fluids containing toxic substances are to be discharged.
There are no other express or implied warranties, such as suitability for a specific purpose, and Wise Co., Ltd. is not responsible for any special, indirect, incidental, or consequential damage or loss based on any reason or theory.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com APPENDIX A (SMT2000 HART Menu) A-1. Menu and setup method The menu and setup method were created based on the Emerson AMS Trex Device communicator. ■ PV Upper/Lower range value This function sets the minimum and maximum pressure range values that the product can measure. ▷...
Page 31
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com ■ Flow meter range This function sets the minimum and maximum flow rate and level range values that the product can measure. ▷ Upper setting ▷ Lower setting ■ Flow unit This is a function to set the flow rate unit measured by the product. C-QIM-2731-E08_EN_Rev.3...
Page 32
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com ■ Device display mode This is a function to change the content displayed on the product. ■ Zero trim This is a function to adjust the zero point in the product installation environment. ■ Low flow cutoff This is a function to ignore minutely detected values.
Page 33
The specifications and appearance of this product are subject to change without notice for quality improvement, and WISE reserves the right to change this. The illustrations used in this instruction manual are for illustrative purposes only and may differ from the actual product WISE CONTROL INC.
Page 35
3. 일반 정보 ........................8 3-1. 특정 사용 조건 ......................8 4. 사양 및 규격....................... 9 5. 프로세스 연결부 ......................11 5-1. SMT2001 ......................11 5-2. SMT2002 / SMT2003 .................... 11 6. 각 부의 명칭 및 작동원리 ..................12 6-1. 각 부의 명칭......................12 6-2.
Page 36
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 8-3. 방폭 인증 정보 ...................... 16 9. HART® 통신......................17 9-1. Electrical Connection Diagram (Using the HART® Protocol) ........17 9-2. 2-Wire (Current) HART® System................17 10. 에러코드........................18 11. 결선........................18 11-1. 결선 방법 ......................18 11-2 접지...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 일반정보 1.1 개요 SMT 200x Series는 산업 공정 전반에 사용하기 위해 특별히 설계되었으며, 액체, 가스 또는 증기 등의 밀도, 압력, 유량 및 절대압력 등을 측정하는 데 사용하는 제품입니다. 이 제품은 HART® 통신이 가능합니다. PC나 HART® 커뮤니케이터를 통해 파라미터 등의 설정이 가능 합니다.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 안전지침 2.1 경고고지 참고 위험 상황을 회피하기 위한 사용자의 운용 안전정보입니다. 2.2 운전자격 설치,시험 운전,작동,유지 보수,폐기 및 처분은 적합한 자격을 갖춘 전문가가 수행할 것을 권장합니다. 전기부품에 대한 작업은 자격을 갖춘 전기기술자가 수행할 것을 권장하며, 관련 규정 및 지침에 따라 수행...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2.5 설치 및 안전지침 번개의 위험이 있거나 과전압에 의한 손상이 있을 수 있다면, 더 강한 낙뢰 보호장치를 사용해야 합니다. ● 과도한 먼지 축적 (5mm 이상) 또는 먼지로 완전히 덮이지 않게 주의해야 합니다. ● 전기 연결 시 최소 보호등급 IP20 이 보장되어야 합니다. ●...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 13 증기 라인에서 제품을 사용할 때에는 냉각기가 제공되어야 합니다. 14 케이블 인입부는 해당 기기의 방폭 등급과 같은 제품 (Ex d IIC)을 사용하여야 합니다. 2.6 일반설치 지침 포장 개봉 시 제품의 파손을 주의하며, 포장박스는 올바르게 폐기하여야 합니다. 다음의...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2.7 전면 디스플레이 방향 디스플레이는 90 도 단위로 회전할 수 있어, 어떤 위치에서도 쉽게 확인할 수 있습니다. 디스플레이 방향을 변경하려면 다음과 같이 진행합니다. 전면 커버를 열기 위해 커버 잠금 볼트를 완전히 체결합니다. 전면 커버를 열어줍니다. 디스플레이...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 사양 및 규격 1. SMT200x series 2. 전원: 24 V DC (12~42 V DC) 3. 출력: 4~20mA with HART® Protocol 4. 방폭등급: 4.1 ATEX, IECEx Flameproof enclosures Ex db IIC T4 / T5 / T6 Gb, Ex tb IIIC T80°C / T90°C / T130°C Db Ta = -40°C to +60 °C ATEX Cert.: CML 17ATEX1235X...
Page 43
8. 공정유체: Gas, Steam and Liquid 9. 정확도: Full scale of ± 0.05 % / Full scale of ± 0.075 % 10. 측정범위: SMT2001: 1~10 mbar to 0.3~30 bar SMT2002: 6~60 mbar to 4~400 bar SMT2003: 20~400 mbar to 0.3~30 bar 11.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 각 부의 명칭 및 작동원리 6-1. 각 부의 명칭 6-2. 작동원리 프로세스 연결부에서 격막을 통해 압력이 전달됩니다. 전달된 압력으로 인해 격막에서 발생하는 물리적 변위량을 센서가 감지합니다. 마이크로프로세서 및 IC 등을 통하여 신호가 변환 및 증폭되어 아날로그 신호(4~20mA)와 디지털 신 호(HART®)로...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com HART® 통신 HART® 사양을 준수하는 추가 신호가 아날로그 출력 신호에 중첩됩니다. HART® 통신장비를 사용하여 프로세스를 구성하고 제품을 사용할 수 있습니다. 당사는 통신 프로세스의 구성을 위해 HART®의 정식 라이선스가 있는 커뮤니케이터의 사용을 추천합니다. 정상작동을 위해서는 아래와 같은 사항이 고려되어 야...
08XX: Sensing part Error 10XX: Display board Error ####: Pressure out of range 위의 에러코드 혹은 다른 문제가 발생할 경우 WISE에 문의 바랍니다. 11. 결선 NOTE. 커넥터 단자가 있는 장치를 사용하는 경우 분리 거리 표준을 준수하고 연결선이 분리되지 않도 록 올바르게 연결하십시오.
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Note. 아래와 같이 연결테이블 및 결선도에 제공된 전기적 사양에 따라 제품을 연결해야 합니다. 연결테이블: Electrical Connections Connection Terminals Supply + (Ub+) PWR + Supply / Test - (Ub-) (COM: PWR - /TEST - ) Test + TEST + Earth 11-2 접지...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 12. 전기 결선도 13. 시운전 1) 제품을 시운전하기 전에 올바르게 설치되었는지 확인하고 연결 결함이 없는지 확인해야 합니다. 2) 사용설명서를 읽고 이해하며, 자격을 갖춘 숙련된 전문가만이 시행하는 것을 권고합니다. 3) 제품은 주어진 사양 내에서만 작동할 수 있습니다. (데이터시트의 기술 데이터를 참조하십시오.) 전류루프를...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 14. 조작방법 디스플레이의 측정값은 문자와 숫자로 구성된 최대 7자로 표시됩니다. 막대 그래프가 디스플레이에 포함되어 있으며, 이는 측정 범위의 백분율로 작용 압력을 표시합니다. 디스플레이는 측정값을 표시할 뿐만 아니라 메뉴를 사용하여 개별 기능을 설정할 수 있습니다. 또한, 측정 범위의...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 15. 로컬 버튼 사용법 15-1. 구성 프로세스 1. Z + S 버튼을 약 2 ~ 5초간 동시에 눌러 시작합니다. 2. Z + S 버튼을 사용하여 원하는 메뉴 항목을 선택합니다. 3. Z + S 버튼을 약 2 ~ 5초간 동시에 눌러 선택한 메뉴 항목에 진입합니다. 4.
Page 56
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 메뉴 항목의 설정 또는 변경은 원하는 메뉴 항목 (예 "DAMPING")에 진입하여 "S" 버튼을 누르면 현재 설정된 값의 첫 번째 숫자가 깜박이며, Z 버튼을 사용하여 원하는 값을 입력합니다. S 버튼을 누르면 다음 자릿수가 깜박이며, 같은 방법으로 원하는 값을 입력합니다. 위의 설정 값은 Z + S 버튼을 동시에 눌러 저장되며...
Page 57
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com ex) Range 0~2 bar 일때 Vent 상태에서 Shift zero를 사용하면 출력값은 4 mA 가 되고 Indicator에는 0 bar로 재조정됩니다. Range가 -1~1 bar일 때 Vent 상태에서 Shift zero를 사용하면 출력값은 12 mA기 되고 Indicator에는 0 bar로 재조정됩니다. 메뉴...
Page 58
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com mA, 20 mA가 순차적으로 출력됩니다. 이 기능을 사용한 후에는 Z+S 버튼을 길게 눌러야 합니다. 2~5초동안 동시에 눌러 설정을 저장하면 디스플레이에 "OK"가 표시됩니다. (단. Test 후 정상적으로 로컬 메 뉴로 나와야 정상 출력이 되고, 자동적으로 로컬 메뉴로 나오는 경우에는 출력값이 루프...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 17. 유량단위 Quantity of Flow (Volumetric flow) m³/s Cubic meter per second m³/m Cubic meter per minute m³/h Cubic meter per hour m³/d Cubic meter per day Liter per second Liter per minute Liter per hour ft³/s Cubic feet per second ft³/m...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 18. 해체 전원이 공급된 상태이거나 위험지역에서는 제품을 절대로 분해하지 말아야 합니다. 제품을 해체하기 전, 반드시 전원을 차단하고 잔여 압력과 잔류 유체를 배출하도록 해야 합니다. 독성이 포함된 공정 유체를 배출하기 전에는 배출 방향을 확인하시고 흡입 및 눈, 피부 접촉을 피하고 자...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 21. 품질보증 보증기간은 출하일로부터 12개월까지입니다. 제품을 비정상적으로 사용하거나 개조하여 손상된 경우에는 보증수리를 할 수 없으며, 본 제품의 재판매자들은 (주)와이즈를 대신하여 어떠한 보증 및 보증기간 연장을 할 수 없습니다. 다이어프램의 손상에는 보증이 적용되지 않으며 보증기간 내에도 사용 시 발생하는 정상적인 마모 때문인 다이어프램의...
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 부록서 A (SMT2000 HART 메뉴) A-1. Menu 및 설정 방법 Menu 및 설정 방법은 Emerson AMS Trex Device communicator 기준으로 작성되었습니다. ■ PV Upper/Lower range value 제품이 측정할 수 있는 최소, 최대 압력 범위 값을 설정하는 기능입니다. ▷...
Page 64
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com ■ Flow meter range 제품이 측정할 수 있는 최소, 최대 유량 및 레벨 범위 값을 설정하는 기능입니다. ▷ Upper setting Device setup Diagnostics/Service Calibration Flow&Level value 값 입력 Flow URV Flow meter range ▷ Lower setting Device setup Diagnostics/Service Calibration...
Page 65
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com ■ Device display mode 제품에 DISPLAY 되는 내용을 변경하는 기능입니다. Device setup Basic setup Device display mode 항목 선택 ■ Zero trim 제품 설치 환경에서의 영점을 조정하는 기능입니다. Device setup Diagnostics/Service Calibration Sensor trim 영점 조정 Zero trim ■...
Page 66
Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 본 설명서의 내용은 심혈을 기울여 제작되었지만, 오탈자 또는 수정해야 할 내용이 있을 수 있으니 이점 양해하여 주시기 바랍니다. 본 제 품의 규격 및 외관은 품질 향상을 위해 사전 통보 없이 변경될 수 있으며, ㈜와이즈는 이에 대한 변경 권리를 가집니다. 본 사용설명서에서 사용하는...