Download Print this page

Wise SMT2001 Manual

Smart pressure transmitter
Hide thumbs Also See for SMT2001:

Advertisement

Available languages

Available languages

Quick Links

Tel +82-2-300-2300
Fax +82-2-300-2400
webmaster@wisecontrol.com
SMART PRESSURE TRANSMITTER
SMT2001 / SMT2002 / SMT2003
0
C-QIM-2731-F16_EN_Rev.1

Advertisement

loading
Need help?

Need help?

Do you have a question about the SMT2001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wise SMT2001

  • Page 1 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com SMART PRESSURE TRANSMITTER SMT2001 / SMT2002 / SMT2003 C-QIM-2731-F16_EN_Rev.1...
  • Page 2: Table Of Contents

    3-1. SPECIFIC CONDITIONS OF USE: ......................7 4. Specifications ................................ 8 5. Process Connection ............................10 5-1. SMT2001 ................................10 5-2. SMT2003 / SMT2003 ........................... 11 6. Each Part Name and Working Principle ....................12 6-1. Each Part Name ............................. 12 6-2.
  • Page 3 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 7. Type of Mounting .............................. 13 7-1. SMT2001 ................................13 7-2. SMT2002 / SMT2002 ........................... 14 8. Name Plate ................................. 15 8-1. Product Information ............................15 8-2. Position ................................15 8-3. Explosion Proof Certification Information .................... 16 9.
  • Page 4 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 21-1. Recalibration ..............................28 21-2. Return ................................28 C-QIM-2731-F16_EN_Rev.1...
  • Page 5: General Information

    3) This manual is part of the product and should be kept in the vicinity of the product installation site so that it can be checked by the operator at all times. 4) WISE Control Inc. All product, product specifications and data are subject to change without notice to improve reliability, function or design or otherwise.
  • Page 6: Safety Instructions

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2. Safety Instructions 2.1 Warning Notices ! NOTE. Operational safety information for users to avoid dangerous situations. 2.2 Qualification of Personnel Installation, commissioning, operation, maintenance, decommissioning and disposal may be carried out only by suitably qualified specialist personnel. Work on electrical components must be performed only by a qualified electrician and in accordance with the applicable regulations and guidelines.
  • Page 7: Installation And Safety Instructions

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2.5 Installation and Safety Instructions In case of increased danger of a lightning strike or damage by overvoltage, more robust lightning ● protection equipment should be used. Do not install on air supply equipment or flow equipment. ●...
  • Page 8: General Installation Instructions

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 10.2 In the case of hydraulic systems, orient the device so that the pressure connector faces upwards (for venting). 10.3 Provide a cooling section when using the device in steam lines. 10.4 Cable should use the same Ex d IIC level. 2.6 General Installation Instructions ...
  • Page 9: Specifications

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Refer to the manufacturer’s instructions to reduce the potential of an electrostatic charging hazard on the equipment enclosure. Some of the enclosures contains aluminum and are considered to present a potential risk of ignition by impact or friction.
  • Page 10 7. Process Material: Gas, Steam and Liquid 8. Accuracy: Full scale of ± 0.05 % / Full scale of ± 0.075 % 9. Measuring range: SMT2001 : 1~10 mbar to 0.3~30 bar SMT2002/SMT2003 : 6~60 mbar to 25~2,500 mbar (SMT2002) 20~400 mbar to 25~2,500 mbar (SMT2003) SMT2002/SMT2003 : 0.3~30 bar to 4~400 bar (SMT2002)
  • Page 11: Process Connection

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 5. Process Connection 5-1. SMT2001 1/4-18" NPT female thread on both sides Flange with fixing thread 7/16-20" UNF C-QIM-2731-F16_EN_Rev.1...
  • Page 12: Smt2003 / Smt2003

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 5-2. SMT2003 / SMT2003 Default Connection: 1/2" NPT (Female) 1/2" NPT (Male) with Union 1/2" PF (Male) wtih Union 3/8" PF (Male) wtih Union 1/4" NPT (Male) with Union Other C-QIM-2731-F16_EN_Rev.1...
  • Page 13: Each Part Name And Working Principle

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 6. Each Part Name and Working Principle 6-1. Each Part Name 6-2. Principle of operation When the pressure is applied to the diaphragm, the pressure sensor detects the change in physical properties, and this change is piled up as amplified analog signal (4~20mA) and Digital signal (HART®) thru Micro Processor and IC.
  • Page 14: Type Of Mounting

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 7. Type of Mounting 7-1. SMT2001 C-QIM-2731-F16_EN_Rev.1...
  • Page 15: Smt2002 / Smt2002

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 7-2. SMT2002 / SMT2002 C-QIM-2731-F16_EN_Rev.1...
  • Page 16: Name Plate

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 8. Name Plate 8-1. Product Information 8-2. Position C-QIM-2731-F16_EN_Rev.1...
  • Page 17: Explosion Proof Certification Information

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 8-3. Explosion Proof Certification Information C-QIM-2731-F16_EN_Rev.1...
  • Page 18: Hart® Communication

    An additional signal complying with the HART® specification is superposed on the analogue output signal. Configuration of the device can be carried out with the aid of a HART® communication device. WISE CONTROL Inc. recommends a communicator by licensed HART® for this purpose.
  • Page 19: 2-Wire (Current) Hart® System

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 9-2. 2-Wire (Current) HART® System 1) Where the cabling is laid in a fixed position, a minimum bend radius of 10 times the diameter must be observed. For flexible use, the limit is 20 times the diameter. 2) In order to electrically connect the device with connector terminals, the cover must be unscrewed.
  • Page 20: Electrical Grounding

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 10-1. Electrical Grounding It is an internal grounding and external grounding as well as the right terminal configuration. The recommended cable grounding wire is AWG24 or higher. When using the extension cable, it is necessary to use thicker standard than the specified grounding wire. Use a washer to prevent loosening during terminal operation and use a plated terminal lug to prevent corrosion and the grounding point must be connected to a building ground connection, floor ground, or ground bus bar.
  • Page 21: Electrical Connection Diagram

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Electrical Connection Diagram Trial Run 1) Before Trial Running the device, check that it has been properly installed, and make sure that it does not show any visible defects. 2) The device may be commissioned only by appropriately qualified and trained personnel who have read and understood the user manual.
  • Page 22: Operation

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Operation Measured values on the displayed with up to Max.7-digit character string comprising letters and numbers. A bar graph is included on the display; This shows the acting pressure as a percentage of the measuring range.
  • Page 23: Local Button Manual

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Local Button Manual 14-1. Configuration Process 1. Start by pressing and holding the Z+S buttons simultaneously for about 2 to 5 s. 2. Select the desired menu item using the Z and S buttons. 3. Invoke the selected menu item by pressing and holding the Z+S buttons simultaneously for about 2 to 5 s.
  • Page 24 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com the currently set value begin to flash. You can now use the Z button to adjust the desired digit. Now press the S button, and the following digit begins to flash and can be adjusted as described. After you confirm the set value by pressing the Z+S buttons simultaneously, the whole value is saved and the display shows “OK”...
  • Page 25: Unit

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2. Measured pressure 3. Measured current(mA) 4. Measured flow DISPLAY ACCURACY Decimal Point Display Setting for Display Output Value UNIT See Page22 Selects the Function FUNCTION Linear Square root √ HIGH/LOW ALARM Selcetion Setting ALARM TYPE High (21mA) / Low (3.6mA) / Keep (Alarm off) Starting Value of Flow Pressure Range In the OUT 0 % menu, Set the desired value and press the Z + S button...
  • Page 26: Flow Unit

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com UNIT Pressure torr torr O (20 ºC /68 ºF) mH2O (4 ºC/39 ºF) inH4O inH2O (4 ºC/39 ºF) mmH4O mmH2O (4 ºC/39 ºF) inH2O inH2O (20 ºC/68 ºF) inHg inHg (0 ºC/32 ºF) ftH2O ftH2O (20 ºC/68 ºF) mmH2O mmH2O (20 ºC/68 ºF) mmHg...
  • Page 27: Decommissioning

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Millimeters Feets Inches Mass Kilograms Tons Pounds Quantity of Mass (Mass flow) kg/s Kilogram per second kg/m Kilogram per minute kg/h Kilogram per hour Ton per minute Ton per hour Ton per day lb/s Pound per second lb/m Pound per minute lb/h...
  • Page 28: Maintenance

    Care should be taken while doing so. If the diaphragm is covered in lime material, It is recommended to request WISE Control Inc. to remove such lime material. Refer to the servicing / repair section.
  • Page 29: Servicing L Repair

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Servicing l Repair 21-1. Recalibration It is possible that the offset value or the scaling value may shift during the lifetime of the device. This is indicated by a deviation in the output signal value with reference to the set measurement range start or end values respectively.
  • Page 30 The specifications and appearance of this product are subject to change without notice for quality improvement, and WISE reserves the right to change this. The illustrations used in this instruction manual are for illustrative purposes only and may differ from the actual product...
  • Page 31 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com SMART PRESSURE TRANSMITTER SMT2001 / SMT2002 / SMT2003 C-QIM-2731-E08_KR_Rev.2...
  • Page 32 3-1. 특정 사용 조건 ..............................9 4. 사양 및 규격 ............................... 10 5. Process Connection ............................12 5-1. SMT2001 ................................12 5-2. SMT2003 / SMT2003........................... 12 6. 각 부의 명칭 및 작동원리 ..........................13 6-1. 각 부의 명칭 ..............................13 6-2.
  • Page 33 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 7-1. SMT2001 ................................14 7-2. SMT2002 / SMT2002........................... 15 8. 명판 ..................................16 8-1. 제품 기본 정보 ............................... 16 8-2. 부착 위치 ................................16 8-3. 방폭 인증 정보 ............................... 17 9. HART® 통신 ..............................18 9-1.
  • Page 34 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 22-1. 재교정 ................................30 22-2. 반품 ................................... 30 APPENDIX A ................................31 A-1. Menu 및 설정 방법 ............................. 31 C-QIM-2731-E08_KR_Rev.2...
  • Page 35: 일반정보

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 1. 일반정보 1.1 개요 SMT 200x Series는 산업 공정의 전반에 사용하기 위해 특별히 설계되었으며, 액체, 가스 또는 증기 등 의 밀도, 압력, 유량 및 절대압력 등을 측정하는 데 사용하는 제품입니다. 이 제품은 HART® 통신이 가능하며, PC나 HART® 커뮤니케이터를 이용하여 파라미터 등의 설정이 가 능합니다.
  • Page 36: 안전지침

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2. 안전지침 2.1 경고고지 참고 – 위험 상황을 회피하기 위한 사용자의 운용 안전정보입니다. 2.2 운전자격 설치, 시험 운전, 작동, 유지 보수, 폐기 및 처분은 적합한 자격을 갖춘 전문가가 수행해야 합니다. 전기부품에 대한 작업은 자격을 갖춘 전기기술자만이 수행할 수 있으며 관련 규정 및 지침에 따라 수행되 어야...
  • Page 37: 설치 및 안전지침

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2.5 설치 및 안전지침 번개가 칠 위험이 있거나, 과전압 때문에 손상이 있을 수 있으면 더 강한 낙뢰 보호장치를 사용하십시오. ● 공기의 공급 또는 흐름 장치에 설치하지 마십시오! ● 과도한 먼지 축적 (5mm 이상) 또는 먼지로 완전히 덮이지 않게 주의하십시오! ●...
  • Page 38: 일반설치 지침

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 10.2 유압 시스템은 압력 커넥터가 위쪽을 향하도록 제품을 설치하십시오. (통풍용) 10.3 증기 라인에서 제품을 사용할 때에는 냉각기가 제공되어야 합니다. 10.4 케이블 인입부는 해당 기기의 방폭 등급과 같은 제품 (Ex d IIC)을 사용하여야 합니다. 2.6 일반설치 지침 ...
  • Page 39: 전면 디스플레이 방향

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 2.9 전면 디스플레이 방향 디스플레이는 90 도 단위로 회전할 수 있어, 어떤 위치에서도 쉽게 확인할 수 있습니다. 디스플레이 방향을 변경하려면 다음과 같이 진행하십시오.  전면 커버를 손으로 돌려 열어줍니다.  디스플레이 모듈의 앞면에 있는 두 개의 십자 나사를 완전히 풀어주고, 디스플레이 모듈을 앞으로 당겨 분리한...
  • Page 40: 사양 및 규격

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 4. 사양 및 규격 1. SMT200x series 2. 전원: 24 V DC (12~42 V DC) 3. 출력: 4~20mA with HART® Protocol 4. 방폭등급: 4.1 ATEX, IECEx Flameproof enclosures Ex db IIC T4 / T5 / T6 Gb, Ex tb IIIC T80°C / T90°C / T130°C Db Ta = -40°C to +60 °C ATEX Cert.
  • Page 41 8. 공정유체: Gas, Steam and Liquid 9. 정확도: Full scale of ± 0.05 % / Full scale of ± 0.075 % 10. 측정범위: SMT2001 : 1~10 mbar to 0.3~30 bar SMT2002/SMT2003 : 6~60 mbar to 25~2,500 mbar (SMT2002) 20~400 mbar to 25~2,500 mbar (SMT2003) SMT2002/SMT2003 : 0.3~30 bar to 4~400 bar (SMT2002)
  • Page 42: Process Connection

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 5. Process Connection 5-1. SMT2001 1/4-18" NPT female thread on both sides Flange with fixing thread 7/16-20" UNF 5-2. SMT2003 / SMT2003 Default Connection: 1/2" NPT (Female) 1/2" NPT (Male) with Union 1/2" PF (Male) wtih Union 3/8"...
  • Page 43: 각 부의 명칭 및 작동원리

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 6. 각 부의 명칭 및 작동원리 6-1. 각 부의 명칭 6-2. 작동원리 압력 입력부의 다이어프램으로 압력이 전달되면 이때 발생하는 물리적 변위량을 센서가 감지하여 마이크로프로세서 및 IC 등을 통하여 변환 증폭되어 아날로그 신호(4~20mA)와 디지털 신호(HART®) 로 중첩되어 출력됩니다. C-QIM-2731-E08_KR_Rev.2...
  • Page 44: Type Of Mounting

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 7. Type of Mounting 7-1. SMT2001 C-QIM-2731-E08_KR_Rev.2...
  • Page 45: Smt2002 / Smt2002

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 7-2. SMT2002 / SMT2002 C-QIM-2731-E08_KR_Rev.2...
  • Page 46: 제품 기본 정보

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 8. 명판 8-1. 제품 기본 정보 8-2. 부착 위치 C-QIM-2731-E08_KR_Rev.2...
  • Page 47: 방폭 인증 정보

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 8-3. 방폭 인증 정보 C-QIM-2731-E08_KR_Rev.2...
  • Page 48: Hart® 통신

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 9. HART® 통신 HART® 사양을 준수하는 추가 신호가 아날로그 출력 신호에 중첩됩니다. HART® 통신장비를 사용하여 프로세스를 구성하고 제품을 사용할 수 있습니다. 당사는 통신 프로세스의 구성을 위해 HART®의 정식 라이선스가 있는 커뮤니케이터의 사용을 추천합니다. 정상작동을 위해서는 아래와 같은 사항이 고려되어 야...
  • Page 49: 2-Wire (Current) Hart® System

    전기 연결에는 차폐 및 멀티 코어 케이블을 사용하십시오. Error code 02XX : AD Board Error 08XX : Sensing part Error 10XX : Display board Error #### : Pressure out of range 위의 에러코드 혹은 다른 문제가 발생할 경우 WISE 에 문의 바랍니다. C-QIM-2731-E08_KR_Rev.2...
  • Page 50: 전원연결

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 전원연결 NOTE. 커넥터 단자가 있는 장치를 사용하는 경우 분리 거리 표준을 준수하고 연결선이 분리되지 않도 록 올바르게 연결하십시오. 아래와 같이 연결테이블 및 결선도에 제공된 전기적 사양에 따라 제품을 연결하십시오. 연결테이블: Electrical Connections Connection Terminals Supply + (Ub+) PWR + Supply / Test - (Ub-) (COM: PWR - /TEST - )
  • Page 51: 터미널 구성도

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 11-2. 터미널 구성도 전기 결선도 C-QIM-2731-E08_KR_Rev.2...
  • Page 52: 시운전

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 시운전 1) 제품을 시운전하기 전에 올바르게 설치되었는지 확인하고 연결 결함이 없는지 확인하십시오. 2) 사용설명서를 읽고 이해하며, 자격을 갖춘 숙련된 전문가만이 시행할 수 있습니다. 3) 제품은 주어진 사양 내에서만 작동할 수 있습니다! (데이터시트의 기술 데이터를 참조하십시오.) 전류루 프를...
  • Page 53: 로컬 버튼 사용법

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 로컬 버튼 사용법 15-1. 구성 프로세스 1. Z + S 버튼을 약 2 ~ 5초간 동시에 눌러 시작하십시오. 2. Z + S 버튼을 사용하여 원하는 메뉴 항목을 선택하십시오. 3. Z + S 버튼을 약 2 ~ 5초간 동시에 눌러 선택한 메뉴 항목에 진입하십시오. 4.
  • Page 54 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 메뉴 항목의 설정 또는 변경은 원하는 메뉴 항목 (예 "DAMPING")에 진입하여 "S" 버튼을 누르면 현재 설정된 값의 첫 번째 숫자가 깜박이며, Z 버튼을 사용하여 원하는 값을 입력합니다. S 버튼을 누르면 다음 자릿수가 깜박이며, 같은 방법으로 원하는 값을 입력합니다. 위의 설정 값은 Z + S 버튼을 동시에 눌러 저장되며...
  • Page 55 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com Vent 상태에서 대기 압력 0 값에 맞춰 출력을 조정하는 기능입니다. ex) Range 0~2 bar 일때 Vent 상태에서 Shift zero를 사용하면 출력값은 4 mA 가 되고 Indicator에는 0 bar로 재조정 됩니다. Range가 -1~1 bar일 때 Vent 상태에서 Shift zero를 사용하면 출력값은 12 mA기 SHIFT ZERO 되고...
  • Page 56 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 설치 후 정상 출력값 (mA) 확인 기능입니다. Z+S 버튼을 동시에 누르면 테스트 출력값 4 mA가 출력되며 Z 버튼을 누르면 12 mA, 20 mA가 순차적으로 출력됩니다. LOOP TEST 이 기능을 사용한 후에는 Z+S 버튼을 길게 눌러야 합니다. 2~5초동안 동시에 눌러 설정을...
  • Page 57: Unit

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com UNIT Pressure torr torr O (20 ºC /68 ºF) mH2O (4 ºC/39 ºF) inH4O inH2O (4 ºC/39 ºF) mmH4O mmH2O (4 ºC/39 ºF) inH2O inH2O (20 ºC/68 ºF) inHg inHg (0 ºC/32 ºF) ftH2O ftH2O (20 ºC/68 ºF) mmH2O mmH2O (20 ºC/68 ºF) mmHg...
  • Page 58: Flow Unit

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com FLOW UNIT Quantity of Flow (Volumetric flow) m³/s Cubic meter per second m³/m Cubic meter per minute m³/h Cubic meter per hour m³/d Cubic meter per day Liter per second Liter per minute Liter per hour ft³/s Cubic feet per second ft³/m...
  • Page 59: 유지보수

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 해체 전원이 공급된 상태이거나 위험지역에서는 제품을 절대로 분해하지 마십시오.   제품을 해체하기 전, 반드시 전원을 차단하고 잔여 압력과 잔류 유체를 배출하십시오.  독성이 포함된 공정 유체를 배출하기 전에는 배출 방향을 확인하시고 흡입 및 눈, 피부 접촉을 피하고 자...
  • Page 60: 품질보증

    Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 품질보증 보증기간은 출하 일로부터 12개월까지입니다. 제품을 비정상적으로 사용하거나 개조하여 손상된 경우에는 보증수리를 할 수 없으며, 본 제품의 재판매자들은 (주)와이즈를 대신하여 어떠한 보증 및 보증기간 연장을 할 수 없습니다. 다이어프램의 손상에는 보증이 적용되지 않으며 보증기간 내에도 사용 시 발생하는 정상적인 마모 때문인 다이어프램의...
  • Page 61 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com APPENDIX A (SMT2000 HART Menu) A-1. Menu 및 설정 방법 Menu 및 설정 방법은 Emerson AMS Trex Device communicator 기준으로 작성되었습니다. ■ PV Upper/Lower range value 제품이 측정할 수 있는 최소, 최대 압력 범위 값을 설정하는 기능입니다. ▷...
  • Page 62 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com ■ Flow meter range 제품이 측정할 수 있는 최소, 최대 유량 및 레벨 범위 값을 설정하는 기능입니다. ▷ Upper setting Device setup Diagnostics/Service Calibration Flow&Level value 값 입력 Flow URV Flow meter range ▷ Lower setting Device setup Diagnostics/Service Calibration...
  • Page 63 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com ■ Device display mode 제품에 DISPLAY 되는 내용을 변경하는 기능입니다. Device setup Basic setup Device display mode 항목 선택 ■ Zero trim 제품 설치 환경에서의 영점을 조정하는 기능입니다. Device setup Diagnostics/Service Calibration Sensor trim 영점 조정 Zero trim ■...
  • Page 64 Tel +82-2-300-2300 Fax +82-2-300-2400 webmaster@wisecontrol.com 본 설명서의 내용은 심혈을 기울여 제작되었지만, 오탈자 또는 수정해야 할 내용이 있을 수 있으니 이점 양해하여 주시기 바랍니다. 본 제 품의 규격 및 외관은 품질 향상을 위해 사전 통보 없이 변경될 수 있으며, ㈜와이즈는 이에 대한 변경 권리를 가집니다. 본 사용설명서에서 사용하는...

This manual is also suitable for:

Smt2002Smt2003