Omron V400-R1CF User Manual page 34

Ultra small multi-code reader
Table of Contents

Advertisement

Settings on the reader
Specify the settings as follows to establish communication with the programmable
controller.
Setting item
Communication speed
Data length
Parity
Stop bit
Header
Footer
Reading valid time
Process failed reading
Settings on OMRON programmable controller CS1
For information about the detailed setting method, refer to the operation manual of your
programmable controller.
Setting item
Dip switch of CPU unit
Program controller system settings
DM setting
Program controller system settings - Details
160
b15
Presence of the arbitrary
communication setting
b11-8
Serial communication mode "11"
b3
Data length
b2
Stop bit
b1-0
Parity
161
b7-0
Communication speed
162
b15-0
Transmission delay time
164
b15-8
Start code
b7-0
End code
165
b12
Presence of the start code
b9-8
Presence of the end code
* 0×00 means a hexadecimal number, and "0" means a binary number.
Setting content
9600 bps
8 bits
None
1 bit
None
CR
Trigger + 2 sec.
Transmits "NL" when no label is found
Transmits "ND" when reading has failed
OFF
160[830E]
161[0006]
162[0000]
164[000D]
165[0100]
Set [1B5A] to DM00100
(Memorize "[ESC]Z" of the ASCII code)
"1"
"1"
"1"
"01"
0×06
0×0000
0×00
0×0D
"0"
"01"
Introduction Procedure
Command
(Factory default setting)
(Factory default setting)
(Factory default setting)
(Factory default setting)
(Factory default setting)
(Factory default setting)
(Factory default setting)
TH0N0L
TI0N0D
Setting content
Arbitrary setting
Nonprocedural
8 bits
1 bit
None
9600 bps
No delay
None
CR
None
The end code is present
V400-R1CF/R1CS
Section 2
33
User's Manual