Section 2
Introduction Procedure
Input/output circuit
External trigger signal input circuit
External trigger signal
Terminal voltage Von when a
transistor is turned on
Terminal voltage Voff when a
transistor is turned off
READ OK/NG signal output circuit
Output system
Rated load
Leak current at OFF
Residual voltage at ON
V400-R1CF/R1CS
30
User's Manual
TRIG
Von/off
SG
Item
Minimum value Maximum value
OK/NG
SG
Item
Vcc
Vcc
Internal
circuit
0 V
1.3 V
2.5 V
Vcc
Internal
circuit
Specification
NPN open collector
24 VDC 30 mA
0.5 mA or less
1.0 V or less