CARE AND MAINTENANCE Care And Maintenance ........................18 HeatMaster Furnaces Inc. Troubleshooting ..........................19 Box 373 C Series Electrical Schematic ....................21-22 Walhalla ND, 58282 Editing Control Settings ......................... 23 Unit Foot Prints ..........................26 Phone: (877) 325-9792 Replacement Components List ..................... 27 Fax (204) 325-9803 Notes ..............................
HeatMaster Furnaces Inc. within 30 days of purchase year. HeatMaster Furnaces Inc. will not be liable for the cost of along with a copy of the original invoice. shipping, labor, replacement, or repair of these parts.
It’s always suggested to use 100% virgin propylene glycol instead added for water with more severe properties or for systems of recycled glycol as it will break down much sooner and create with more chemically demanding requirements. glycolic acid. HeatMaster C Series Furnace Operating Manual...
The WARNING furnace must be filled until the water comes out of the vent • All installations and operations of your HeatMaster product pipe on the top of the furnace. must follow STATE, PROVINCIAL, and LOCAL LAWS pertaining •...
To adjust the damper, see page 25, cleaning the furnace and ensuring proper chimney installation can also affect the draft. Do not connect this unit to a chimney flue serving another appliance. HeatMaster C Series Furnace Operating Manual...
• Never allow combustible material to accumulate on the bigger than the actual furnace, with about a 4’ extra length front furnace foundation. and back so you have a solid working area. • Do not install on a combustible base. HeatMaster C Series Furnace Operating Manual...
TRENCH WIRING HeatMaster Furnaces Inc recommends the trench be 24” to All wiring must conform to local codes. Use an electrical wire rated 36” deep. Take into consideration soil conditions as rocky soil and approved for underground installations. This wiring can be conditions can cause the casing of the pipe to be damaged and placed in the same trench below the water lines.
The best place to mount the main pump is on the supply outlet. dealer can design and install a system to best fit your needs. Placing the pump inside the building can lead to cavitation and airlock problems. HeatMaster C Series Furnace Operating Manual...
Page 11
Main Power Switch Lead In Power Junction Box Main Power Connection Cold Water Return Line Receptacles Hot Water Supply Line HeatMaster C Series Furnace Operating Manual...
Page 12
The following and mechanical safety controls of the original boiler, are examples of basic interior connections. HeatMaster • provide for a changeover from one fuel to the other Furnaces inc. carries the necessary parts for installation.
Page 13
(sidearm) systems. They are mounted on the supply line and pre-heat the water going into the hot water tank. HeatMaster C Series Furnace Operating Manual...
How it Works Filling the Furnace with Water The C Series furnace is a 409 stainless steel outdoor furnace Your furnace has a vent pipe that protrudes through the roof with a water jacket surrounding the firebox. This reservoir of and contains the water level float indicator.
This creates sweating you and damaging the furnace. inside the firebox and causes water to collect in the ash drawer and on the door jamb which may last a couple of days and is normal. HeatMaster C Series Furnace Operating Manual...
Page 16
HeatMaster C Series Furnace Operating Manual...
Page 17
Some coal smolders better during cycles than others. Furnace Control - Your HeatMaster C Series furnace uses a Shortening the differential on the Ranco temperature control factory-programmed aqua stat control to maintain your water to make it cycle more often can help but is a less efficient burn.
See page 5 for exact specifications. ATTENTION: Avoid direct water pressure to electrical • Change any water filter cartridges and inspect all of your components and connections. system for leaks. HeatMaster C Series Furnace Operating Manual...
4. Check for closed valves to ensure water flow. Close all combustion air inlets on the furnace. 5. Check the temperature of water exiting the furnace, entering the building being heated, and before and after each heat exchanger. HeatMaster C Series Furnace Operating Manual...
Page 20
Check all plumbing in the system to ensure there are no leaks. The Ranco Temperature control is giving the user an error message: Instructions for dealing with Ranco ETC settings and error codes are included in the owner’s manual on page 23. HeatMaster C Series Furnace Operating Manual...
Front Light High Limit Switch Temperature Sensor Ranco 120 COM Furnace Switch Light Switch Power Switch 120V Power Supply Draft ELECTRICAL SCHEMATIC C150/MF-3000e C250/MF-5000e Damper C375/MF-7000e Actuator Colour Copy of Wiring Diagram 5084D0180 HeatMaster C Series Furnace Operating Manual...
Page 22
Front Light High Limit Switch Temperature Sensor Ranco 120 COM Furnace Switch Light Switch Power Switch 120V Power Supply Draft Draft ELECTRICAL SCHEMATIC C500/MF-10,000e C800/MF-20,000e Damper Actuator Colour Copy of Wiring Diagram 5084D0181 HeatMaster C Series Furnace Operating Manual...
DESCRIPTION increase or the down key to decrease the differential to the F or C Fahrenheit or Celsius Scale desired setting. S1 blinking Setpoint Temperature DIF1 blinking Differential Temperature C1/H1 Cooling or Heating Mode HeatMaster C Series Furnace Operating Manual...
Page 24
This condition can not be field repaired. Replace the control. CL Appears if calibration mode has been entered. To correct: Remove power to the control for at least five seconds. Reapply power. If the CL message still appears, replace the control. HeatMaster C Series Furnace Operating Manual...
Page 25
Note: Ensure that the draft plate is tightly sealed against the air opening inlet when in the closed position. This can be done using the manual override on the actuator (select models), or by forcing the draft plate tightly against the air inlet before tightening the 10mm bolt in step 5. HeatMaster C Series Furnace Operating Manual...
NOTES HeatMaster C Series Furnace Operating Manual...
Page 29
HeatMaster C Series Furnace Operating Manual...
Page 30
For more information on our parts or to arrange product installation please contact your local HeatMaster dealer. HeatMaster Furnaces Inc. Box 158 Winkler, Manitoba, Canada...
Need help?
Do you have a question about the C Series and is the answer not in the manual?
Questions and answers