Doc.no.AS*-OMZ0007-A PRODUCT NAME Speed Controller Standard Type / Large Flow In-line Type MODEL/ Series/ Product Number AS420 /AS500 /AS600 AS800 / AS900...
Speed Controller Standard Type Large Flow In-line Type / AS Series Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
Page 4
Speed Controller Standard Type Large Flow In-line Type / AS Series Safety Instructions Caution We develop, design, and manufacture our products to be used for automatic control equipment, and provide them for peaceful use in manufacturing industries. Use in non-manufacturing industries is not covered. Products we manufacture and sell cannot be used for the purpose of transactions or certification specified in the Measurement Act.
2. Specific Product Precautions Mounting (5)Do not use tools such as pliers to rotate the Design/ Selection knob. Warning This can cause idle rotation of the knob or damage. (1) Confirm the specifications. (6) Confirm the air flow direction. Do not operate at pressures, temperatures, etc., Mounting backward is dangerous, because the beyond the range of specifications, as this can speed adjustment needle will not work and the...
Page 6
Air Supply Piping (3) Ensure that the fluid ambient Caution temperatures are within the specified range. (1) Preparation before piping If the fluid temperature is 5 or less, the ℃ Before piping is connected, it should be moisture in the circuit could freeze, causing thoroughly blown out with air (flushing) or damage to the seals or leading to equipment washed to remove chips, cutting oil and other...
Page 7
Maintenance Warning (1) Perform maintenance and inspection according to the procedures indicated in the operation manual. If handled improperly, malfunction or damage of machinery and equipment may occur. (2) Maintenance work If handled improperly, compressed air can be dangerous. Assembly, handling, repair element...
3. Application This product is designed to control the speed of a pneumatic actuator. 4. Specifications Fluid Proof pressure 1.5MPa Max. operating pressure 1.0MPa Min. operating pressure 0.05MPa -5 to 60℃ (No freezing) Ambient and fluid temperature 5.Troubleshooting Trouble Possible causes Countermeasures The speed (flow rate) The direction of check valve...