USER MANUAL BC-K200 Intel 7th/6th Gen. Core Pentium / Celeron Industrial Rackmount Chassis BC-K200 M1...
Page 2
BC-K200 ® Intel 7th / 6th Gen. Core / Pentium ® Celeron Industrial Rackmount Chassis COPYRIGHT NOTICE & TRADEMARK All trademarks and registered trademarks mentioned herein are the property of their respective owners. This manual is copyrighted in July 2020. You may not reproduce or transmit in any form or by any means, electronic, or mechanical, including photocopying and recording.
Page 3
FCC NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Contents Introduction ..................1-1 About This Manual ..............1-2 Getting Started ..................2-1 Packing List ................2-2 System Overview ............... 2-3 Front View ..................2-3 Rear View ..................2-3 Top View.................... 2-3 Quarter View ..................2-4 System Specifications ..............2-5 Safety Precautions ..............
Page 5
3.10 DVI (Digital Video Interface) Port ..........3-14 3.11 VGA Port .................. 3-15 3.12 Front Panel Connector ............. 3-16 3.13 LAN & USB Port ............... 3-17 3.14 Line-in, Line-out, Mic-in Port ............ 3-19 3.15 RS-232/422/485 (COM2) Selection ......... 3-20 3.16 COM2 Auto Detection Selection ..........3-21 3.17 Hardware Power Failure Selection ..........
Page 9
Revision History The revision history of BC-K200 User Manual is described below: Version No. Revision History Date 20120/07/16 Initial Release...
Introduction This chapter provides the introduction for BC-K200 system as well as the framework of the user manual. The following topic is included: • About This Manual BC-K200 SERIES USER MANUAL Page: 1-1...
It is not intended for general users. The following section outlines the structure of this user manual. Chapter 1 Introduction This chapter provides the introduction for the BC-K200 system as well as the framework of the user manual. Chapter 2 Getting Started This chapter describes the package contents and outlines the system specifications.
Getting Started This chapter provides the information for the BC-K200 system. It describes the package contents and outlines the system specifications. The following topics are included: • Package List • System Overview • System Specification • Safety Precautions Experienced users can go to Chapter 3 System Configuration on page 3-1 for a quick start.
2.1 Packing List If you discover any of the items listed below are damaged or lost, please contact your local distributor immediately. Item Q’ty BC-K200 Quick Reference Guide Manual / Driver DVD Mini Jumper (2.0 mm) BC-K200 SERIES USER MANUAL Page: 2-2...
® LAN1: Intel PHY 219LM (GbE) ® LAN 2: Intel LAN 210AT (GbE) Supports Wake-On-LAN 1 x CPU fan 2 x system fans (with iron mesh & air filter) BC-K200 SERIES USER MANUAL Page: 2-5...
Page 17
1 x Power Button Button 1 x Reset Button Environment Operating Temp. 0°C ~ 40°C (32°F ~ 104°F) Storage Temp. -20°C ~ 80°C (-4°F ~ 176°F) Operating Humidity 20%~ 90% (non-condensing) BC-K200 SERIES USER MANUAL Page: 2-6...
Avoid direct sunlight exposure for a long period of time (for example, in a closed car in summer time. Also avoid the system from any heating device.). Or do not use BC-K200 when it has been left outdoors in a cold winter day. •...
The following topics are included: • External I/O Ports Diagrams • Main Board Jumper Settings and Component Locations • How to Set Jumpers • Setting Main Board Connectors and Jumpers BC-K200 SERIES USER MANUAL Page: 3-1...
Chapter 3 Hardware Configuration 3.1 External System I/O Ports Diagram I/O Ports Diagram RJ45 10/100/1000 Reset Button LAN Connector Power Button Power LED HDD LED COM2 Audio DVI-D Power Supply COM1 Connector PS/2 KB/ MS Connector BC-K200 SERIES USER MANUAL Page: 3-2...
USB2, USB3 VGA Port RS-232/422/485 (COM2) Selection COM2 Auto Detection Selection Hardware Power Failure Selection Flash Descriptor Override Selection LAN2 Enable / Disable Selection Mini PCI Express Voltage Selection JP13 VCCIO Voltage Selection JP10 BC-K200 SERIES USER MANUAL Page: 3-3...
PIN1 & PIN2 to create one setting by shorting. You can either connect PIN2 & PIN3 to create another setting. The same jumper diagrams are applied all through this manual. The figure below shows what the manual diagrams look and what they represent. BC-K200 SERIES USER MANUAL Page: 3-6...
Page 25
Jumper Block looks like this Jumper Settings 2 pin Jumper close(enabled) Looks like this 3 pin Jumper 2-3 pin close(enabled) Looks like this Jumper Block 1-2 pin close(enabled) Looks like this BC-K200 SERIES USER MANUAL Page: 3-7...
COM1: COM1 Connector, fixed as RS-232. ASSIGNMENT DCD# DTR# DSR# RTS# CTS# COM2: COM2 Connector selectable as RS-232/422/485. COM2/ The pin assignments are as follows: COM1 Signal RS-232 RS-422 RS-485 DCD# RS-485- RS-485+ DTR# DSR# RTS# CTS# BC-K200 SERIES USER MANUAL Page: 3-8...
Page 27
COM3, COM4, COM5, COM6: COM Connector, fixed as RS-232. ASSIGNMENT ASSIGNMENT DCD# DSR# RTS# CTS# DTR# COM3/ COM4/ Note: Pin 9 is selectable for RI, +5V or +12V for COM3 COM5/ and COM4 only. COM6 BC-K200 SERIES USER MANUAL Page: 3-9...
Note 2: To clear CMOS data, users must power off the computer and set the jumper to “Clear CMOS” as shown above. After 5 to 6 seconds, set the jumper back to “NC” and power on the computer. BC-K200 SERIES USER MANUAL Page: 3-10...
Chapter 3 Hardware Configuration COM Port RI / Voltage Selection COM3 and COM4 RI & Voltage Selection Selection Jumper Setting Jumper Illustration JPCOM3/JPCOM4 JPCOM3/JPCOM4 JPCOM3/JPCOM4 Note: Manufacturing default is RI. BC-K200 SERIES USER MANUAL Page: 3-11...
TMDS_D3- A DVI-D connector transfer only digital signals, providing faster transfer rates and better quality than their predecessor, the VGA cable. It is most commonly used to connect computer video cards to LCD monitors. BC-K200 SERIES USER MANUAL Page: 3-14...
No LAN Switch/HUB connected Right Side LED Yellow Color Blinking LAN Message Active No LAN Message Active USB 3.0 signals: ASSIGNMENT ASSIGNMENT USB_N1 USB_N2 USB_P1 USB_P2 USB3_RX_N1 USB3_RX_N2 USB3_RX_P1 USB3_RX_P2 USB3_TX_N1 USB3_TX_N2 USB3_TX_P1 USB3_TX_P2 BC-K200 SERIES USER MANUAL Page: 3-17...
Page 36
No LAN Switch/HUB connected Right Side LED Yellow Color Blinking LAN Message Active No LAN Message Active USB 3.0 signals: ASSIGNMENT ASSIGNMENT USB_N3 USB_N4 USB_P3 USB_P4 USB3_RX_N3 USB3_RX_N4 USB3_RX_P3 USB3_RX_P4 USB3_TX_N3 USB3_TX_N4 USB3_TX_P3 USB3_TX_P4 BC-K200 SERIES USER MANUAL Page: 3-18...
Chapter 3 Hardware Configuration 3.14 Line-in, Line-out, Mic-in Port AUDIO1: Line-In, Line-Out & Microphone The connector can also support only Microphone. Line-In: ASSIGNMENT HD_LINE-IN-L HD_LINE-IN-R Line-Out: ASSIGNMENT LINE-OUT-L AUDIO1 LINE-OUT-R MIC-In: ASSIGNMENT HD_MIC1-L_L HD_MIC1-R_L BC-K200 SERIES USER MANUAL Page: 3-19...
Chapter 3 Hardware Configuration 3.16 COM2 Auto Detection Selection JP4: COM2 Auto Detection Selection The selections are as follows: Jumper Setting Selection Jumper Illustration (Pin Closed) Normal Auto ***Manufacturing Default – Auto. BC-K200 SERIES USER MANUAL Page: 3-21...
JP3: Flash Descriptor Override Selection Description: Jumper for enable or disable the permission to updating BIOS ME firmware. The selections are as follows: Jumper Setting Selection Jumper Illustration (Pin Closed) Disable Open Enable ***Manufacturing Default – Disable. BC-K200 SERIES USER MANUAL Page: 3-23...
Chapter 3 Hardware Configuration 3.20 Mini PCIE Voltage Selection JP13: Mini PCIE Voltage Selection The selections are as follows: Jumper Setting Selection Jumper Illustration (Pin Closed) 3.3V JP13 3.3V_AUX JP13 ***Manufacturing Default –3.3V_AUX. BC-K200 SERIES USER MANUAL Page: 3-25...
Chapter 3 Hardware Configuration 3.24 CPU / System Fan Connectors CPU_FAN1: CPU Fan Connector SYS_FAN1: System Fan Connector 1 ASSIGNMENT CPU_FAN1 VCC12 CPU_FANTAC CPU_FANCTRL SYS_FAN1 SYS_FAN2: System Fan Connector 2 ASSIGNMENT VCC12 SYS_FAN2 BC-K200 SERIES USER MANUAL Page: 3-32...
Note: USB1 is only available for C236/Q170 SKU, not available for H110 SKU. 3.27 Internal USB 2.0 Conncetors USB2, USB3: Internal USB 2.0 Connector ASSIGNMENT ASSIGNMENT USB2_P USB2_P USB2_N USB2_N VCC5 VCC5 USB2/ USB3 BC-K200 SERIES USER MANUAL Page: 3-34...
Chapter 4 Software Utilities 4.1 Introduction Enclosed with the BC-K200 Series package is our driver utilities contained in a DVD-ROM disk. Refer to the following table for driver locations: Filename (Assume that DVD Purpose ROM drive is D:) Shell Win7 Win8.1 Win10...
OS installation. Please follow the steps below: Insert the driver disk into a DVD-ROM device. Under Windows system, go to the directory where the Utility driver is located. Run the application with the “Administrator” privilege. BC-K200 SERIES USER MANUAL Page: 4-5...
Manager. Follow the steps below to install: Insert the driver disk into a DVD-ROM device. Under Windows system, go to the directory where the driver is located. Run the application with the “Administrator” privilege. BC-K200 SERIES USER MANUAL Page: 4-6...
Chapter 4 Software Utilities 4.5 Installing VGA Driver Utility The VGA interface embedded with our BC-K200 can support a wide range of display. To install the VGA Driver, simply follow the following steps: Insert the driver disk into a DVD-ROM device.
Chapter 4 Software Utilities 4.6 Installing LAN Driver Utility BC-K200 is enhanced with LAN function that can support various network adapters. Installation programs for LAN drivers are listed as follows: For more details on Installation procedure, please refer to Readme.txt file found on LAN Driver Utility.
Run the application with the “Administrator” privilege. Follow the instructions on the screen to complete the installation. Once the installation is completed, shut down the system and restart it in order for the changes to take effect. BC-K200 SERIES USER MANUAL Page: 4-9...
Setup information is retained when the system is powered off. The BIOS Setup Utilities consist of the following menu items: Main Menu • Advanced Menu • Chipset Menu • Security Menu • Boot Menu • Save & Exit Menu • BC-K200 SERIES USER MANUAL Page: 5-1...
Chapter 5 BIOS Setup 5.1 Introduction The BC-K200 System uses an AMI (American Megatrends Incorporated) Aptio BIOS that is stored in the Serial Peripheral Interface Flash Memory (SPI Flash) and can be updated. The SPI Flash contains the built-in BIOS setup program, Power-On Self-Test (POST), PCI auto-configuration utility, LAN EEPROM information, and Plug and Play support.
POST message will be displayed: Figure 5-2. POST Screen with AMI Logo Press <Del> or <Esc> to access the Setup Utility program and the Main menu of the Aptio Setup Utility will appear on the screen as below: BC-K200 SERIES USER MANUAL Page: 5-3...
Page 68
English. You may use <↑> or <↓> key to select among the items and press <Enter> to confirm and enter the sub-menu. The following table provides the list of the navigation keys that you can use while operating the BIOS setup menu. BC-K200 SERIES USER MANUAL Page: 5-4...
Page 69
The CMOS battery is The battery may be losing power and users should bad or has been recently replace the battery immediately. Also, this message is replaced. displayed once the new battery is replaced. BC-K200 SERIES USER MANUAL Page: 5-5...
Month/ Date/ Year]. Users can directly enter values or use <+> or <-> arrow keys to increase/decrease it. The “Day” is automatically changed. System Time Hour, minute, second Sets the system time. The format is [Hour: BC-K200 SERIES USER MANUAL Page: 5-6...
Enables or Disables BIOS support for Security Device - Enabled security device. O.S will not show security Support Device. TCG EFI protocol and INT1A interface will not be available. Security Device No changeable options Security Device Information. Status BC-K200 SERIES USER MANUAL Page: 5-8...
SUSPEND button RAM) is pressed. Lock Legacy - Disabled Enables or Disables Lock of Legacy Resources - Enabled Resources. - Disabled S3 Video Repost Enables or Disables S3 Video Repost. - Enabled BC-K200 SERIES USER MANUAL Page: 5-9...
Options Description/Purpose ME Firmware No changeable options Displays the ME Firmware Version. Version ME Firmware No changeable options Displays the ME Firmware Mode. Mode ME Firmware No changeable options Displays the ME Firmware SKU. BC-K200 SERIES USER MANUAL Page: 5-10...
Serial Port 4 Sets parameters of Serial Port 4 Sub-Menu Configuration (COMD). Serial Port 5 Sets parameters of Serial Port 5 Sub-Menu Configuration (COME). Serial Port 6 Sets parameters of Serial Port 6 Sub-Menu Configuration (COMF). BC-K200 SERIES USER MANUAL Page: 5-11...
Page 76
No changeable options of Serial Port 1. - Auto Selects IRQ and I/O - IO=3F8h; IRQ=4; resource settings for Serial - IO=3F8h; IRQ=3,4,5,6,7,9,10,11,12; Port 1. Change Settings - IO=2F8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-12...
Page 77
No changeable options of Serial Port 2. - Auto Selects IRQ and I/O - IO=2F8h; IRQ=3; resource settings for Serial - IO=3F8h; IRQ=3,4,5,6,7,9,10,11,12; Port 2. Change Settings - IO=2F8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-13...
Page 78
No changeable options of Serial Port 3. - Auto Selects IRQ and I/O - IO=3E8h; IRQ=10; resource settings for Serial - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; Port 3. Change Settings - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2F0h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-14...
Page 79
No changeable options of Serial Port 4. - Auto Selects IRQ and I/O - IO=2E8h; IRQ=5; resource settings for Serial - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; Port 4. Change Settings - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2F0h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-15...
Page 80
No changeable options of Serial Port 5. - Auto Selects IRQ and I/O - IO=2F0h; IRQ=7; resource settings for Serial - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; Port 5. Change Settings - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2F0h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-16...
Page 81
No changeable options of Serial Port 6. - Auto Selects IRQ and I/O - IO=2E0h; IRQ=6; resource settings for Serial - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; Port 6. Change Settings - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2F0h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-17...
Displays the VCORE CPU voltage in VCORE No changeable options supply. Displays the voltage level of VSB5V VSB5V No changeable options in supply. Displays the voltage level of VCC5V VCC5V No changeable options in supply. BC-K200 SERIES USER MANUAL Page: 5-18...
Page 83
Displays the voltage level of VCC3V VCC3V No changeable options in supply. Displays the voltage level of VSB3V VSB3V No changeable options in supply. Displays the voltage level of VSB5V VSB5V No changeable options in supply. BC-K200 SERIES USER MANUAL Page: 5-19...
Fan1 Control - Auto Duty-Cycle Mode fan 1. Manual Duty Mode - Numeric Manual mode fan control. Users can (from 1 to 100) write the expected duty cycle (PWM fan type) from 1 to 100. BC-K200 SERIES USER MANUAL Page: 5-20...
Selects 1s (second) or 60s (minute) as Watchdog timer unit - 60s the time unit of Watchdog timer. Count for Timer Numeric Sets the timeout for Watchdog timer. (Seconds) (from 1 to 255) (Max. value: 255 seconds or minutes) BC-K200 SERIES USER MANUAL Page: 5-21...
L4 Cache No changeable options L4 Cache Size CPU VMX hardware support for No changeable options virtual machines. SMX/TXT No changeable options Secure Mode extensions or TXT (LT) support. TXT stands for Trusted Execution Technology. BC-K200 SERIES USER MANUAL Page: 5-22...
Page 87
Enables/Disables Software Guard (SGX) - Enabled Extensions (SGX) Hyper-Threading - Disabled Enabled for Windows XP and Linux - Enabled (OS optimized for Hyper-Threading Technology) and Disabled for other OS (OS not optimized for Hyper-Threading Technology). BC-K200 SERIES USER MANUAL Page: 5-23...
Indicates whether the connected options SATA device supports Software Setting Preservation (SSP). Port 0-3 for H110 sku. - Disabled Enables or Disables SATA Port Port 0-5 for Q170 sku. - Enabled Device. Port 0-7 for C236 sku. BC-K200 SERIES USER MANUAL Page: 5-24...
Page 89
Chapter 5 BIOS Setup BIOS Setting Options Description/Purpose Hot Plug - Disabled Enables or Disables Hot Plug - Enabled function to designate a SATA port device as hot-pluggable. BC-K200 SERIES USER MANUAL Page: 5-25...
Support - Enabled disabled, IPv4 PXE boot option will not be created. Ipv4 HTTP - Disabled Enables/Disables IPv4 HTTP boot Support - Enabled support. If disabled, IPv4 HTTP boot support will not be available. BC-K200 SERIES USER MANUAL Page: 5-26...
Page 91
Number of seconds to wait for PXE boot Numeric (from 0 to 5) time to abort after the Esc key is pressed. Media detect Number of times that the media presence Numeric (from 1 to 50) count will be checked. BC-K200 SERIES USER MANUAL Page: 5-27...
The USB Configuration allows users to enable/disable USB mass storage driver support. USB Configuration Screen BIOS Setting Options Description/Purpose USB Mass Storage Driver - Disabled Enables/Disables USB mass storage driver Support - Enabled support. BC-K200 SERIES USER MANUAL Page: 5-28...
This menu allows users to configure advanced Chipset settings such as System Agent (SA) and PCH-IO configuration parameters. Chipset Screen BIOS Setting Options Description/Purpose System Agent (SA) Sub-Menu System Agent (SA) parameters. Configuration PCH-IO Configuration Sub-Menu PCH parameters. BC-K200 SERIES USER MANUAL Page: 5-29...
I/O devices in virtualized environment. Memory Displays the DRAM information on the Sub-Menu Configuration platform. BC-K200 SERIES USER MANUAL Page: 5-30...
Page 95
Chapter 5 BIOS Setup BIOS Setting Options Description/Purpose Graphics Sub-Menu Configures Graphics configurations. Configuration PEG Port Configuration Sub-Menu PEG Port Configuration. (PCI_E1) - Disabled VT-d Enables or Disables VT-d function. - Enabled BC-K200 SERIES USER MANUAL Page: 5-31...
Primary Display or selects - PEG SG for Switchable Gfx. - PCIE Internal Graphics - Auto Keeps IGFX enabled based on the setup - Disabled options. - Enabled LCD Control Sub-Menu LCD Control sub-menu. BC-K200 SERIES USER MANUAL Page: 5-32...
- Auto - Auto Configures PEG 0:1:0 maximum speed. - Gen 1 Max Link Speed - Gen 2 - Gen 3 Detect - Disabled Detects Non-Compliance PCI Express Non-Compliance - Enabled Device in PEG. Device BC-K200 SERIES USER MANUAL Page: 5-34...
Displays the information of Channel 1 No changeable options Q170 and C236 sku. Slot 0. Channel 1 Slot 1 for Displays the information of Channel 1 No changeable options Q170 and C236 sku. Slot 1. BC-K200 SERIES USER MANUAL Page: 5-35...
Enables or Disables integrated LAN to Enable - Enabled wake up the system. Specifies what state to go to when power - Power On State After G3 is re-applied following a power failure - Power Off (G3 state). BC-K200 SERIES USER MANUAL Page: 5-36...
Configures PCI Express Root Sub-Menu Port 7 settings. (PCI_E3) PCI Express Root Port 9 Configures PCI Express Root Sub-Menu Port 9 settings. (PCI_E2) Mini-PCI Express Root Configures Mini-PCI Express Sub-Menu Port 1 Root Port 1 settings. BC-K200 SERIES USER MANUAL Page: 5-37...
Page 102
- L1 mode that activates when the bus is - L0sL1 not being used. - Auto Force L0s – Force all links to L0s State Auto – BIOS Auto configure Disable – Disables ASPM BC-K200 SERIES USER MANUAL Page: 5-38...
Page 103
- Gen2 - Gen3 Detect Non-Compliance Device Detects a Non-Compliance PCI - Disabled Express device that is connected to - Enabled the PCI Express port. If enabled, it will take more time during POST. BC-K200 SERIES USER MANUAL Page: 5-39...
Page 104
- L1 mode that activates when the bus is - L0sL1 not being used. - Auto Force L0s – Force all links to L0s State Auto – BIOS Auto configure Disable – Disables ASPM BC-K200 SERIES USER MANUAL Page: 5-40...
Page 105
- Gen2 - Gen3 Detect Non-Compliance Device Detects a Non-Compliance PCI - Disabled Express device that is connected to - Enabled the PCI Express port. If enabled, it will take more time during POST. BC-K200 SERIES USER MANUAL Page: 5-41...
Page 106
- L1 mode that activates when the bus is - L0sL1 not being used. - Auto Force L0s – Force all links to L0s State Auto – BIOS Auto configure Disable – Disables ASPM BC-K200 SERIES USER MANUAL Page: 5-42...
Page 107
- Gen2 - Gen3 Detect Non-Compliance Device Detects a Non-Compliance PCI - Disabled Express device that is connected to - Enabled the PCI Express port. If enabled, it will take more time during POST. BC-K200 SERIES USER MANUAL Page: 5-43...
Page 108
Force L0s – Force all links to L0s State - Auto Auto – BIOS Auto configure Disable – Disables ASPM L1 Substates - Disabled PCI Express L1 Substates settings. - L1.1 - L1.2 - L1.1 & L1.2 BC-K200 SERIES USER MANUAL Page: 5-44...
Page 109
- Gen3 Detect Non-Compliance - Disabled Detects a Non-Compliance PCI Express Device device that is connected to the Mini PCI - Enabled Express root port. If enabled, it will take more time during POST. BC-K200 SERIES USER MANUAL Page: 5-45...
Setup utility. Security Screen BIOS Setting Options Description/Purpose Administrator Password Password can be 3-20 Specifies the administrator alphanumeric characters. password. User Password Password can be 3-20 Specifies the user password. alphanumeric characters. BC-K200 SERIES USER MANUAL Page: 5-46...
Page 111
<Enter>, and the password dialog entry box appears. Select the configured Administrator Password or User Password that you want to delete. Leave the dialog box blank and press <Enter>. Press <Enter> again when the password confirmation box appears. BC-K200 SERIES USER MANUAL Page: 5-47...
Bootup NumLock State - On (default) Selects the NumLock state after the - Off system is powered on. • On: Enables the NumLock function automatically after the system is powered on. • Off: Disables the NumLock BC-K200 SERIES USER MANUAL Page: 5-48...
Page 113
Sets the system boot order. - Disabled Hard Drive BBS Priorities Sub-Menu Defines the boot order for all the hard drives connected to the system, e.g. SATA, USB drive. CSM Configuration Sub-Menu Configures CSM parameters. BC-K200 SERIES USER MANUAL Page: 5-49...
Page 114
USB storage. Press Enter to enter the sub-menu and press <↑> or <↓> arrow keys to select the device. Another way is to press <+> or <-> to move the selected device up/down in the priority list. BC-K200 SERIES USER MANUAL Page: 5-50...
Enables or Disables CSM Support. - Enabled CSM16 Module No changeable options Displays the CSM 16 Module version. Version Boot option filter - UEFI and Legacy This option controls Legacy/UEFI ROMs - Legacy only priority. - UEFI only BC-K200 SERIES USER MANUAL Page: 5-51...
Page 116
Controls the execution of UEFI and - UEFI Legacy Video Option ROM. - Legacy Other PCI - Do not launch Determines Option ROM execution policy devices - UEFI for devices other than Network, Storage or - Legacy Video. BC-K200 SERIES USER MANUAL Page: 5-52...
Discard Changes and Reset to discard any changes you have made and restore the factory BIOS defaults. Load User Defaults You may simply press F3 at any time to load the Optimized Values which resets all BIOS settings to the factory defaults. Save & Exit Screen BC-K200 SERIES USER MANUAL Page: 5-53...
Page 118
Save the changes done so far as User Save as User Defaults No changeable options Defaults. Restore the User Defaults to all the Restore User Defaults No changeable options setup options. Forces to boot from selected Boot Override - [Drive(s)] [drive(s)]. BC-K200 SERIES USER MANUAL Page: 5-54...
BC-K200 system. The following topics are included: BC-K200 System Exploded Diagram • BC-K200 System Fan Assembly Exploded Diagram • BC-K200 DVD & 3.5” HDD Module Assembly • Exploded Diagram BC-K200 DVD & 2.5” HDD Module Assembly • Exploded Diagram BC-K200 3.5”...
Page 120
Appendix A System Diagrams BC-K200 System Exploded Diagram BC-K200 SERIES USER MANUAL Page: A-2...
Page 121
Appendix A System Diagrams Component Name P/N No. Q’ty BC-K200 BOT CASE PWS IO PLATE KIT 20-104-03061498 FOR TEL(w/Paint)(Black) FAN_FIXED_FRAME_PLATE_ASSY_EXP See Page A-4 FLAT HEAD SCREW #2 / M3x0.5Px5mm 22-215-30005011 HEX CU BOSS M3x0.5Px3L,H=5mm 22-290-30005051 BU-2509 Main PCB ASSY See Page A-10...
Appendix A System Diagrams BC-K200 System Fan Assembly Exploded Diagram 2 16X 1 2X Component Name P/N No. Q’ty KT-7290 SYSTEM FAN (80x80x20mm) 21-004-08080134 L=300mm FLAT HEAD SCREW #2 / T4.7x11mm 82-712-47011018 BC-K200 FAN FIXED FRAME PLATE 20-104-03062498 (w/Paint)(Black) Fan_holder_for_80-80...
Appendix A System Diagrams BC-K200 DVD & 3.5” HDD Module Assembly Exploded Diagram 5 4X Component Name P/N No. Q’ty BC-K200 DVD HDD HOLDER (w/Paint) (Black) 20-129-03061498 DVD Player FILLISTER HEAD SCREW M2x0.4Px2.5mm 22-272-20002011 HDD_3.5inch_SATA_STAND_RUBBER_KIT_ See Page A-7 WASHER (OD=Φ10mm,ID=Φ3mmx0.8T) 23-312-30080101 TRUSS HEAD SCREW M3x0.5Px6mm...
Appendix A System Diagrams BC-K200 DVD & 2.5” HDD Module Assembly Exploded Diagram 5 4X Component Name P/N No. Q’ty BC-K200 DVD HDD HOLDER(w/Paint)(Black) 20-129-03061498 DVD Player FILLISTER HEAD SCREW M2x0.4Px2.5mm 22-272-20002011 HDD_2.5inch_DOUBLE_SATA_STAND_ See Page A-8 RUBBER_KIT_EXP WASHER (OD=Φ10mm,ID=Φ3mmx0.8T) 23-312-30080101 TRUSS HEAD SCREW M3x0.5Px6mm...
Appendix A System Diagrams BC-K200 Main Board I/O Shield Assembly Exploded Diagram Component Name P/N No. Q’ty BU-2509_MAIN_PCB_ASSY HEX CU BOSS UNC No.4-40,L=5,H=6mm 22-392-40005301 BK-0940 IO SHIELD 80-010-07001357 BC-K200 SERIES USER MANUAL Page: A-10...
Appendix A System Diagrams BC-K200 Rack Mount Holder Assembly Exploded Diagram 3 2X Component Name P/N No. Q’ty BC-K200 RACK MOUNT HOLDER 20-229-03061498 (w/Paint)(Black) ALUMINUM HANDLE 20-035-01001000 FLAT HEAD SCREW #2/M5x0.8Px8mm 22-215-50008011 BC-K200 SERIES USER MANUAL Page: A-11...
Appendix B Technical Summary This appendix will give you a brief introduction of the allocation maps for BC-K200 resources. The following topics are included: • Block Diagram • Interrupt Map • I/O Map • Memory Map • Configuring Watchdog Timer •...
ALC 888S-VD2 High Definition Codec SPI FLASH ROM LOW PIN COUNT 80 PORT for Debug COM 1/3/4/5/6 RS232 FINTEK Connector COM3/4 support 5V/12V LPC SIO HW monitor COM 2 F81866AD-I RS232/422/485 PS/2 Keyboard Mouse BC-K200 SERIES USER MANUAL Page: B-2...
IRQ 86 Microsoft ACPI-Compliant System IRQ 87 Microsoft ACPI-Compliant System IRQ 88 Microsoft ACPI-Compliant System IRQ 89 Microsoft ACPI-Compliant System IRQ 90 Microsoft ACPI-Compliant System IRQ 91 Microsoft ACPI-Compliant System IRQ 92 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-3...
Page 133
IRQ 115 Microsoft ACPI-Compliant System IRQ 116 Microsoft ACPI-Compliant System IRQ 117 Microsoft ACPI-Compliant System IRQ 118 Microsoft ACPI-Compliant System IRQ 119 Microsoft ACPI-Compliant System IRQ 120 Microsoft ACPI-Compliant System IRQ 121 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-4...
Page 134
IRQ 144 Microsoft ACPI-Compliant System IRQ 145 Microsoft ACPI-Compliant System IRQ 146 Microsoft ACPI-Compliant System IRQ 147 Microsoft ACPI-Compliant System IRQ 148 Microsoft ACPI-Compliant System IRQ 149 Microsoft ACPI-Compliant System IRQ 150 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-5...
Page 135
IRQ 173 Microsoft ACPI-Compliant System IRQ 174 Microsoft ACPI-Compliant System IRQ 175 Microsoft ACPI-Compliant System IRQ 176 Microsoft ACPI-Compliant System IRQ 177 Microsoft ACPI-Compliant System IRQ 178 Microsoft ACPI-Compliant System IRQ 179 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-6...
Page 136
IRQ 266 Microsoft ACPI-Compliant System IRQ 267 Microsoft ACPI-Compliant System IRQ 268 Microsoft ACPI-Compliant System IRQ 269 Microsoft ACPI-Compliant System IRQ 270 Microsoft ACPI-Compliant System IRQ 271 Microsoft ACPI-Compliant System IRQ 272 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-7...
Page 137
IRQ 295 Microsoft ACPI-Compliant System IRQ 296 Microsoft ACPI-Compliant System IRQ 297 Microsoft ACPI-Compliant System IRQ 298 Microsoft ACPI-Compliant System IRQ 299 Microsoft ACPI-Compliant System IRQ 300 Microsoft ACPI-Compliant System IRQ 301 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-8...
Page 138
IRQ 324 Microsoft ACPI-Compliant System IRQ 325 Microsoft ACPI-Compliant System IRQ 326 Microsoft ACPI-Compliant System IRQ 327 Microsoft ACPI-Compliant System IRQ 328 Microsoft ACPI-Compliant System IRQ 329 Microsoft ACPI-Compliant System IRQ 33 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-9...
Page 139
IRQ 353 Microsoft ACPI-Compliant System IRQ 354 Microsoft ACPI-Compliant System IRQ 355 Microsoft ACPI-Compliant System IRQ 356 Microsoft ACPI-Compliant System IRQ 357 Microsoft ACPI-Compliant System IRQ 358 Microsoft ACPI-Compliant System IRQ 359 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-10...
Page 140
IRQ 382 Microsoft ACPI-Compliant System IRQ 383 Microsoft ACPI-Compliant System IRQ 384 Microsoft ACPI-Compliant System IRQ 385 Microsoft ACPI-Compliant System IRQ 386 Microsoft ACPI-Compliant System IRQ 387 Microsoft ACPI-Compliant System IRQ 388 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-11...
Page 141
IRQ 411 Microsoft ACPI-Compliant System IRQ 412 Microsoft ACPI-Compliant System IRQ 413 Microsoft ACPI-Compliant System IRQ 414 Microsoft ACPI-Compliant System IRQ 415 Microsoft ACPI-Compliant System IRQ 416 Microsoft ACPI-Compliant System IRQ 417 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-12...
Page 142
IRQ 440 Microsoft ACPI-Compliant System IRQ 441 Microsoft ACPI-Compliant System IRQ 442 Microsoft ACPI-Compliant System IRQ 443 Microsoft ACPI-Compliant System IRQ 444 Microsoft ACPI-Compliant System IRQ 445 Microsoft ACPI-Compliant System IRQ 446 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-13...
Page 143
IRQ 469 Microsoft ACPI-Compliant System IRQ 470 Microsoft ACPI-Compliant System IRQ 471 Microsoft ACPI-Compliant System IRQ 472 Microsoft ACPI-Compliant System IRQ 473 Microsoft ACPI-Compliant System IRQ 474 Microsoft ACPI-Compliant System IRQ 475 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-14...
Page 144
IRQ 498 Microsoft ACPI-Compliant System IRQ 499 Microsoft ACPI-Compliant System IRQ 500 Microsoft ACPI-Compliant System IRQ 501 Microsoft ACPI-Compliant System IRQ 502 Microsoft ACPI-Compliant System IRQ 503 Microsoft ACPI-Compliant System IRQ 504 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-15...
Page 145
Microsoft ACPI-Compliant System IRQ 509 Microsoft ACPI-Compliant System IRQ 510 Microsoft ACPI-Compliant System IRQ 511 Microsoft ACPI-Compliant System Note: These resource information were gathered using Windows 10 (the IRQ could be assigned differently depending on OS). BC-K200 SERIES USER MANUAL Page: B-16...
Page 148
Appendix B Technical Summary I/O MAP ASSIGNMENT 0x000000B4-0x000000B5 Programmable interrupt controller 0x000000B8-0x000000B9 Programmable interrupt controller 0x000000BC-0x000000BD Programmable interrupt controller 0x000004D0-0x000004D1 Programmable interrupt controller 0x00000040-0x00000043 System timer 0x00000050-0x00000053 System timer BC-K200 SERIES USER MANUAL Page: B-19...
Page 149
0xDF730000-0xDF73FFFF Intel USB 3.0 eXtensible Host Controller ® 0xDF740000-0xDF743FFF High Definition Audio Controller 0xDF744000-0xDF747FFF Intel 100 Series Chipset Family PMC ® 0xDF748000-0xDF749FFF Standard SATA AHCI Controller 0xDF74A000-0xDF7470FF Intel 100 Series Chipset Family SMBus ® BC-K200 SERIES USER MANUAL Page: B-20...
Page 151
Appendix B Technical Summary MEMORY MAP ASSIGNMENT 0xFF000000-FFFFFFFF Intel 82802 Firmware Hub Device ® 0xFF000000-FFFFFFFF Intel 82802 Firmware Hub Device ® BC-K200 SERIES USER MANUAL Page: B-22...
Page 152
To exit the Extended Function Mode, writing 0xAA to the EFER is required. Once the chip exits the Extended Function Mode, it is in the normal running mode and is ready to enter the configuration mode. BC-K200 SERIES USER MANUAL Page: B-23...
Page 153
;---------------------------------Enable Watch dog feature ---------------------------------------------- 030h ;------------------------------- Enable Watch PME-------------------------------------------------------- 0FAh ;-------------------------- Set second as counting unit -------------------------------------------------- 0f5h ; ---------------- Set timeout interval as 30seconds and start counting ----------------------- 0f6h ;---------------------------------Exit the extended function mode -------------------- 0aah BC-K200 SERIES USER MANUAL Page: B-24...
Page 154
(3) The system will go into the BIOS setup menu. (4) Select [Boot] menu and enter into [CSM Configuration] menu. (5) Set [Boot option filter] to [UEFI Only] and press <F4> key to save configuration and restart the system. BC-K200 SERIES USER MANUAL Page: B-25...
Page 155
(6) Press <ESC> or <DEL> to enter into BIOS setup menu again. (7) Select [Boot] menu and set [UEFI: Built-in EFI Shell] as the boot device. (8) Press <F4> key to save the configuration and restart the system to boot into EFI Shell environment. BC-K200 SERIES USER MANUAL Page: B-26...
Page 156
/?” to see all the definition of each control option. The recommended options for BIOS ROM update include the following parameters: Program main BIOS image. /B: Program Boot Block. /N: Program NVRAM. /X: Don’t check ROM ID. BC-K200 SERIES USER MANUAL Page: B-27...
Page 157
BIOS ROM and make the system unable to boot up next time. After BIOS update procedure is completed, the following picture will display: BC-K200 SERIES USER MANUAL Page: B-28...
Page 158
Restart the system and boot up with the new BIOS configurations. The BIOS Update is completed after the system is restarted. Reboot the system and verify if the BIOS version shown on the initialization screen has been updated. BC-K200 SERIES USER MANUAL Page: B-29...
Need help?
Do you have a question about the BC-K200 and is the answer not in the manual?
Questions and answers