protech BC-K200 User Manual

Intel 7th/6th gen. core/pentium/celeron industrial rackmount chassis
Table of Contents

Advertisement

Quick Links

USER
MANUAL
BC-K200 M1
BC-K200
Intel 7th/6th Gen. Core
Pentium / Celeron Industrial
Rackmount Chassis
/
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BC-K200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for protech BC-K200

  • Page 1 USER MANUAL BC-K200 Intel 7th/6th Gen. Core Pentium / Celeron Industrial Rackmount Chassis BC-K200 M1...
  • Page 2 BC-K200 ® Intel 7th / 6th Gen. Core / Pentium ® Celeron Industrial Rackmount Chassis COPYRIGHT NOTICE & TRADEMARK All trademarks and registered trademarks mentioned herein are the property of their respective owners. This manual is copyrighted in July 2020. You may not reproduce or transmit in any form or by any means, electronic, or mechanical, including photocopying and recording.
  • Page 3 FCC NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 4: Table Of Contents

    Contents Introduction ..................1-1 About This Manual ..............1-2 Getting Started ..................2-1 Packing List ................2-2 System Overview ............... 2-3 Front View ..................2-3 Rear View ..................2-3 Top View.................... 2-3 Quarter View ..................2-4 System Specifications ..............2-5 Safety Precautions ..............
  • Page 5 3.10 DVI (Digital Video Interface) Port ..........3-14 3.11 VGA Port .................. 3-15 3.12 Front Panel Connector ............. 3-16 3.13 LAN & USB Port ............... 3-17 3.14 Line-in, Line-out, Mic-in Port ............ 3-19 3.15 RS-232/422/485 (COM2) Selection ......... 3-20 3.16 COM2 Auto Detection Selection ..........3-21 3.17 Hardware Power Failure Selection ..........
  • Page 6 Software Utilities ................. 4-1 Introduction ................4-2 Intel ® Chipset Device Software Installer........4-5 Installing Utility for Windows 7/8.1/10 ........4-5 ® Installing Intel Trusted Execution Engine Installation Utility ..4-6 Installing VGA Driver Utility ............4-7 Installing LAN Driver Utility ............4-8 Sound Driver Utility ..............
  • Page 7 BC-K200 System Exploded Diagram ............A-2 BC-K200 System Fan Assembly Exploded Diagram ....... A-4 BC-K200 DVD & 3.5” HDD Module Assembly Exploded Diagram ... A-5 BC-K200 DVD & 2.5” HDD Module Assembly Exploded Diagram ... A-6 BC-K200 3.5” HDD Module Assembly Exploded Diagram ....... A-7 BC-K200 2.5”...
  • Page 8 Configuring WatchDog Timer ..............B-23 Flash BIOS Update ................. B-25...
  • Page 9 Revision History The revision history of BC-K200 User Manual is described below: Version No. Revision History Date 20120/07/16 Initial Release...
  • Page 10: Introduction

    Introduction This chapter provides the introduction for BC-K200 system as well as the framework of the user manual. The following topic is included: • About This Manual BC-K200 SERIES USER MANUAL Page: 1-1...
  • Page 11: About This Manual

    It is not intended for general users. The following section outlines the structure of this user manual. Chapter 1 Introduction This chapter provides the introduction for the BC-K200 system as well as the framework of the user manual. Chapter 2 Getting Started This chapter describes the package contents and outlines the system specifications.
  • Page 12: Getting Started

    Getting Started This chapter provides the information for the BC-K200 system. It describes the package contents and outlines the system specifications. The following topics are included: • Package List • System Overview • System Specification • Safety Precautions Experienced users can go to Chapter 3 System Configuration on page 3-1 for a quick start.
  • Page 13: Packing List

    2.1 Packing List If you discover any of the items listed below are damaged or lost, please contact your local distributor immediately. Item Q’ty BC-K200 Quick Reference Guide Manual / Driver DVD Mini Jumper (2.0 mm) BC-K200 SERIES USER MANUAL Page: 2-2...
  • Page 14: System Overview

    Chapter 2 Getting Started 2.2 System Overview Unit: mm Front View Rear View Top View 428.20 BC-K200 SERIES USER MANUAL Page: 2-3...
  • Page 15: Quarter View

    Chapter 2 Getting Started Quarter View BC-K200 SERIES USER MANUAL Page: 2-4...
  • Page 16: System Specifications

    ®  LAN1: Intel PHY 219LM (GbE) ®  LAN 2: Intel LAN 210AT (GbE)  Supports Wake-On-LAN  1 x CPU fan  2 x system fans (with iron mesh & air filter) BC-K200 SERIES USER MANUAL Page: 2-5...
  • Page 17  1 x Power Button Button  1 x Reset Button Environment Operating Temp.  0°C ~ 40°C (32°F ~ 104°F) Storage Temp.  -20°C ~ 80°C (-4°F ~ 176°F) Operating Humidity  20%~ 90% (non-condensing) BC-K200 SERIES USER MANUAL Page: 2-6...
  • Page 18: Safety Precautions

    Avoid direct sunlight exposure for a long period of time (for example, in a closed car in summer time. Also avoid the system from any heating device.). Or do not use BC-K200 when it has been left outdoors in a cold winter day. •...
  • Page 19: Hardware Configuration

    The following topics are included: • External I/O Ports Diagrams • Main Board Jumper Settings and Component Locations • How to Set Jumpers • Setting Main Board Connectors and Jumpers BC-K200 SERIES USER MANUAL Page: 3-1...
  • Page 20: External System I/O Ports Diagram

    Chapter 3 Hardware Configuration 3.1 External System I/O Ports Diagram I/O Ports Diagram RJ45 10/100/1000 Reset Button LAN Connector Power Button Power LED HDD LED COM2 Audio DVI-D Power Supply COM1 Connector PS/2 KB/ MS Connector BC-K200 SERIES USER MANUAL Page: 3-2...
  • Page 21: Jumper & Connector Quick Reference Table

    USB2, USB3 VGA Port RS-232/422/485 (COM2) Selection COM2 Auto Detection Selection Hardware Power Failure Selection Flash Descriptor Override Selection LAN2 Enable / Disable Selection Mini PCI Express Voltage Selection JP13 VCCIO Voltage Selection JP10 BC-K200 SERIES USER MANUAL Page: 3-3...
  • Page 22: Component Locations

    SATA3 SATA1 BU-2509 Connector, Jumper and Component Locations (Top Side) Note 1: BC-K200 uses motherboard BU-2509 Note 2: C236 SKU has SATA1~6, JDIMM1~4, PCI_E1~4 available. Q170 SKU has SATA1~6, JDIMM1~4, PCI_E1~4 available. H110 SKU only has SATA1~4, JDIMM2, 4, PCI_E1~3 available. USB1 is not available for H110 SKU.
  • Page 23 Chapter 3 Hardware Configuration BU-2509 Connector, Jumper and Component Locations (Bottom Side) BC-K200 SERIES USER MANUAL Page: 3-5...
  • Page 24: How To Set Jumpers

    PIN1 & PIN2 to create one setting by shorting. You can either connect PIN2 & PIN3 to create another setting. The same jumper diagrams are applied all through this manual. The figure below shows what the manual diagrams look and what they represent. BC-K200 SERIES USER MANUAL Page: 3-6...
  • Page 25 Jumper Block looks like this Jumper Settings 2 pin Jumper close(enabled) Looks like this 3 pin Jumper 2-3 pin close(enabled) Looks like this Jumper Block 1-2 pin close(enabled) Looks like this BC-K200 SERIES USER MANUAL Page: 3-7...
  • Page 26: Com Port And Connectors

    COM1: COM1 Connector, fixed as RS-232. ASSIGNMENT DCD# DTR# DSR# RTS# CTS# COM2: COM2 Connector selectable as RS-232/422/485. COM2/ The pin assignments are as follows: COM1 Signal RS-232 RS-422 RS-485 DCD# RS-485- RS-485+ DTR# DSR# RTS# CTS# BC-K200 SERIES USER MANUAL Page: 3-8...
  • Page 27 COM3, COM4, COM5, COM6: COM Connector, fixed as RS-232. ASSIGNMENT ASSIGNMENT DCD# DSR# RTS# CTS# DTR# COM3/ COM4/ Note: Pin 9 is selectable for RI, +5V or +12V for COM3 COM5/ and COM4 only. COM6 BC-K200 SERIES USER MANUAL Page: 3-9...
  • Page 28: Clear Cmos Data Selection

    Note 2: To clear CMOS data, users must power off the computer and set the jumper to “Clear CMOS” as shown above. After 5 to 6 seconds, set the jumper back to “NC” and power on the computer. BC-K200 SERIES USER MANUAL Page: 3-10...
  • Page 29: Com Port Ri / Voltage Selection

    Chapter 3 Hardware Configuration COM Port RI / Voltage Selection COM3 and COM4 RI & Voltage Selection Selection Jumper Setting Jumper Illustration JPCOM3/JPCOM4 JPCOM3/JPCOM4 JPCOM3/JPCOM4 Note: Manufacturing default is RI. BC-K200 SERIES USER MANUAL Page: 3-11...
  • Page 30: Digital I/O Port Connector

    Chapter 3 Hardware Configuration 3.8 Digital I/O Port Connector JDIO1 JDIO1: Digital Input / Output Port Connector: ASSIGNMENT ASSIGNMENT VCC5 VCC12 DIN1 DOUT1 DIN2 DOUT2 DIN3 DOUT3 DIN4 DOUT4 DIN5 DOUT5- DIN6 DOUT6 DIN7 DOUT7 DIN8 DOUT8 BC-K200 SERIES USER MANUAL Page: 3-12...
  • Page 31: Keyboard & Mouse Port

    Chapter 3 Hardware Configuration 3.9 Keyboard & Mouse Port KB_MS1: PS/2 Keyboard & Mouse Port Mouse: ASSIGNMENT ASSIGNMENT MSCLK VCC5 MSDATA Keyboard: ASSIGNMENT ASSIGNMENT KBCLK VCC5 KBDATA KB_MS1 BC-K200 SERIES USER MANUAL Page: 3-13...
  • Page 32: Dvi (Digital Video Interface) Port

    TMDS_D3- A DVI-D connector transfer only digital signals, providing faster transfer rates and better quality than their predecessor, the VGA cable. It is most commonly used to connect computer video cards to LCD monitors. BC-K200 SERIES USER MANUAL Page: 3-14...
  • Page 33: Vga Port

    Chapter 3 Hardware Configuration 3.11 VGA Port VGA: VGA (Video Graphics Array) Connector The pin assignments are as follows: ASSIGNMENT CRT_RED CRT_GREEN CRT_BLUE CRT_VCC CRT_SDA CRT_HSYNC CRT_VSYNC CRT_SCL BC-K200 SERIES USER MANUAL Page: 3-15...
  • Page 34: Front Panel Connector

    Chapter 3 Hardware Configuration 3.12 Front Panel Connector FP1: Front Panel Connector ASSIGNMENT ASSIGNMENT HDD_LED+ PWR_LED+ HDD_LED- PWR_LED- PWR_BTN RST_BTN VCC5 BC-K200 SERIES USER MANUAL Page: 3-16...
  • Page 35: Lan & Usb Port

    No LAN Switch/HUB connected Right Side LED Yellow Color Blinking LAN Message Active No LAN Message Active USB 3.0 signals: ASSIGNMENT ASSIGNMENT USB_N1 USB_N2 USB_P1 USB_P2 USB3_RX_N1 USB3_RX_N2 USB3_RX_P1 USB3_RX_P2 USB3_TX_N1 USB3_TX_N2 USB3_TX_P1 USB3_TX_P2 BC-K200 SERIES USER MANUAL Page: 3-17...
  • Page 36 No LAN Switch/HUB connected Right Side LED Yellow Color Blinking LAN Message Active No LAN Message Active USB 3.0 signals: ASSIGNMENT ASSIGNMENT USB_N3 USB_N4 USB_P3 USB_P4 USB3_RX_N3 USB3_RX_N4 USB3_RX_P3 USB3_RX_P4 USB3_TX_N3 USB3_TX_N4 USB3_TX_P3 USB3_TX_P4 BC-K200 SERIES USER MANUAL Page: 3-18...
  • Page 37: Line-In, Line-Out, Mic-In Port

    Chapter 3 Hardware Configuration 3.14 Line-in, Line-out, Mic-in Port AUDIO1: Line-In, Line-Out & Microphone The connector can also support only Microphone. Line-In: ASSIGNMENT HD_LINE-IN-L HD_LINE-IN-R Line-Out: ASSIGNMENT LINE-OUT-L AUDIO1 LINE-OUT-R MIC-In: ASSIGNMENT HD_MIC1-L_L HD_MIC1-R_L BC-K200 SERIES USER MANUAL Page: 3-19...
  • Page 38: Rs-232/422/485 (Com2) Selection

    3.15 RS-232/422/485 (COM2) Selection JP2: RS-232/422/485 (COM2) Selection The selections are as follows: Jumper Setting Selection Jumper Illustration (Pin Closed) Open RS-232 RS-422 1-2, 3-4, 9-10 RS-485 1-2, 5-6, 7-8 ***Manufacturing Default – RS-232. BC-K200 SERIES USER MANUAL Page: 3-20...
  • Page 39: Com2 Auto Detection Selection

    Chapter 3 Hardware Configuration 3.16 COM2 Auto Detection Selection JP4: COM2 Auto Detection Selection The selections are as follows: Jumper Setting Selection Jumper Illustration (Pin Closed) Normal Auto ***Manufacturing Default – Auto. BC-K200 SERIES USER MANUAL Page: 3-21...
  • Page 40: Hardware Power Failure Selection

    Chapter 3 Hardware Configuration 3.17 Hardware Power Failure Selection JP1: Hardware Power Failure Selection Selection Jumper Setting Jumper Illustration Enable Disable Note: Manufacturing default is Disable. BC-K200 SERIES USER MANUAL Page: 3-22...
  • Page 41: Flash Descriptor Override Selection

    JP3: Flash Descriptor Override Selection Description: Jumper for enable or disable the permission to updating BIOS ME firmware. The selections are as follows: Jumper Setting Selection Jumper Illustration (Pin Closed) Disable Open Enable ***Manufacturing Default – Disable. BC-K200 SERIES USER MANUAL Page: 3-23...
  • Page 42: Lan2 Enable / Disable Selection

    Chapter 3 Hardware Configuration 3.19 LAN2 Enable / Disable Selection JP5: LAN2 Enable / Disable Selection The selections are as follows: Jumper Setting Selection Jumper Illustration (Pin Closed) Enable Disable ***Manufacturing Default – Enable. BC-K200 SERIES USER MANUAL Page: 3-24...
  • Page 43: Mini Pcie Voltage Selection

    Chapter 3 Hardware Configuration 3.20 Mini PCIE Voltage Selection JP13: Mini PCIE Voltage Selection The selections are as follows: Jumper Setting Selection Jumper Illustration (Pin Closed) 3.3V JP13 3.3V_AUX JP13 ***Manufacturing Default –3.3V_AUX. BC-K200 SERIES USER MANUAL Page: 3-25...
  • Page 44: Vccio Voltage Selection

    Chapter 3 Hardware Configuration 3.21 VCCIO Voltage Selection JP10: VCCIO Voltage Selection The selections are as follows: Jumper Setting Selection Jumper Illustration (Pin Closed) 1.0V JP10 0.95V JP10 ***Manufacturing Default – 0.95V. BC-K200 SERIES USER MANUAL Page: 3-26...
  • Page 45: Mini Pci Express Slot

    Chapter 3 Hardware Configuration 3.22 MINI PCI Express Slot MPCIE1: Mini-PCI Express Slot ASSIGNMENT ASSIGNMENT WAKE_N 3.3V_SB 1.5V CLKREQ# REFCLK- REFCLK+ PERST# MPCIE1 PE_RX_N 3.3V_SB PE_RX_P 1.5V SMB_CLK PE_TX_N SMB_DATA PE_TX_P USB_N USB_P 3.3V_SB 3.3V_SB 1.5V 3.3V_SB BC-K200 SERIES USER MANUAL Page: 3-27...
  • Page 46: Pci Express Slots

    HSIP2 HSIN2 HSIP7 HSIN7 + 3.3V HSIP3 + 3.3V HSIN3 RSVD PERST# RSVD HSIP8 REFCLK+ RSVD HSIN8 REFCLK- HSIP4 HSIP0 HSIN4 HSIP9 HSIN0 HSIN9 RSVD HSIP5 HSIN5 HSIP10 HSIN10 HSIN12 HSIN14 HSIP11 HSIP13 HSIP15 BC-K200 SERIES USER MANUAL Page: 3-28...
  • Page 47 RSVD HSON8 + 3.3V_AXU PRSNT#2 WAKE# RSVD HSOP4 HSOP9 HSON4 HSON9 HSOP0 HSON0 HSOP5 HSOP10 PRSNT#2 HSON5 HSON10 HSOP1 HSON1 HSOP6 HSOP11 HSON6 HSON11 HSON13 HSIP15 HSIN15 HSOP12 HSON12 HSOP14 PRSNT#2 HSIN14 RSVD HSOP13 BC-K200 SERIES USER MANUAL Page: 3-29...
  • Page 48 HSIN3 + 3.3V + 3.3V HSIP1 RSVD PERST# HSIN1 + 12V RSVD HSOP2 + 12V HSON2 + 12V HSOP0 HSON0 SMB_CLK HSOP3 SMB_DATA PRSNT#2 HSON3 + 3.3V HSOP1 RSVD HSON1 PRSNT#2 + 3.3V_AXU WAKE# BC-K200 SERIES USER MANUAL Page: 3-30...
  • Page 49 ASSIGNMENT PRSNT#1 + 3.3V + 12V PERST# + 12V REFCLK+ REFCLK- HSIP0 HSIN0 + 3.3V ASSIGNMENT ASSIGNMENT + 12V + 3.3V_AXU + 12V WAKE# + 12V RSVD SMB_CLK HSOP0 SMB_DATA HSON0 + 3.3V PRSNT#2 BC-K200 SERIES USER MANUAL Page: 3-31...
  • Page 50: Cpu / System Fan Connectors

    Chapter 3 Hardware Configuration 3.24 CPU / System Fan Connectors CPU_FAN1: CPU Fan Connector SYS_FAN1: System Fan Connector 1 ASSIGNMENT CPU_FAN1 VCC12 CPU_FANTAC CPU_FANCTRL SYS_FAN1 SYS_FAN2: System Fan Connector 2 ASSIGNMENT VCC12 SYS_FAN2 BC-K200 SERIES USER MANUAL Page: 3-32...
  • Page 51: Serial Ata (Sata) Connectors

    SATA1, SATA2, SATA3, SATA4, SATA5, SATA6: SATA Connectors SATA1-6 Pin Assignment: ASSIGNMENT SATA1/ SATA_TX_P SATA3/ SATA_TX_N SATA5/ SATA_RX_N SATA_RX_P Notes: 1. C236 SKU supports SATA1~SATA6. 2. Q170 SKU supports SATA1~SATA6. SATA2/ 3. H110 SKU supports SATA1~SATA4. SATA4/ SATA6/ BC-K200 SERIES USER MANUAL Page: 3-33...
  • Page 52: Internal Usb 3.0 Connector

    Note: USB1 is only available for C236/Q170 SKU, not available for H110 SKU. 3.27 Internal USB 2.0 Conncetors USB2, USB3: Internal USB 2.0 Connector ASSIGNMENT ASSIGNMENT USB2_P USB2_P USB2_N USB2_N VCC5 VCC5 USB2/ USB3 BC-K200 SERIES USER MANUAL Page: 3-34...
  • Page 53: Display Port Connector

    Chapter 3 Hardware Configuration 3.28 Display Port Connector DP1: Display Port Connector ASSIGNMENT ASSIGNMENT VCC5 VCC3 VCC3 AUX+ AUX_EN# DATA3- DATA2- DATA3+ DATA2+ DATA1- DATA0- DATA1+ DATA0+ NOTE: BU-2509RA-D0P / D1P / D6P don’t support DP. BC-K200 SERIES USER MANUAL Page: 3-35...
  • Page 54: Power Input Connectors

    + 3.3V + 3.3V -12V + 3.3V PSON + 5V + 5V + 5V + 5V_SB + 5V + 12V + 5V + 12V + 3.3V ATX_PWR2: Power Connector ASSIGNMENT ASSIGNMENT +12V +12V ATX_PWR2 BC-K200 SERIES USER MANUAL Page: 3-36...
  • Page 55: Speaker Connector

    JSPEAKER: Speaker Connector ASSIGNMENT SPKR_SIGNAL SPKR_SIGNAL SPKR_SIGNAL SPKR_VCC JSPEAKER 3.31 LPC Connector JLPC1: LPC Connector ASSIGNMENT ASSIGNMENT DREQ0 SUS_TAT CLK RUN SERIRQ 3VSB SMBDATA SMBCLK LAD0 LAD1 VCC3 LAD2 LAD3 JLPC1 VCC5 RESET FRAME BC-K200 SERIES USER MANUAL Page: 3-37...
  • Page 56: Software Utilities

    • Installing Intel Chipset Device Software Installer • Installing Utility for Windows 7/8.1/10 ® • Installing Intel Trusted Execution Engine Installation Utility • Installing VGA Driver Utility • Installing LAN Driver Utility • Installing Sound Driver Utility BC-K200 SERIES USER MANUAL Page: 4-1...
  • Page 57: Introduction

    Chapter 4 Software Utilities 4.1 Introduction Enclosed with the BC-K200 Series package is our driver utilities contained in a DVD-ROM disk. Refer to the following table for driver locations: Filename (Assume that DVD Purpose ROM drive is D:) Shell Win7 Win8.1 Win10...
  • Page 58 (64-bit)\USB3.0 Host Controller ® D:\Q170\Driver\Platform\Win7 Intel Management Engine    (64-bit)\ME Components installer ® D:\Q170\Driver\Platform\Win7 Intel Rapid Storage    ® (64-bit)\RAID Technology (Intel RST). D:\Q170\Driver\Platform\ Intel® Chipset Device    BC-K200 SERIES USER MANUAL Page: 4-3...
  • Page 59 Intel USB 3.0 eXtensible    Win10(64-bit)\USB3.0 Host Controller ® D:\Q170\Driver\Platform\ Intel Management Engine    Win10(64-bit)\ME Components installer ® D:\Q170\Driver\Platform\ Intel Rapid Storage    ® Win10(64-bit)\RAID Technology (Intel RST). BC-K200 SERIES USER MANUAL Page: 4-4...
  • Page 60: Intel ® Chipset Device Software Installer

    OS installation. Please follow the steps below: Insert the driver disk into a DVD-ROM device. Under Windows system, go to the directory where the Utility driver is located. Run the application with the “Administrator” privilege. BC-K200 SERIES USER MANUAL Page: 4-5...
  • Page 61: Installing Intel ® Trusted Execution Engine Installation Utility

    Manager. Follow the steps below to install: Insert the driver disk into a DVD-ROM device. Under Windows system, go to the directory where the driver is located. Run the application with the “Administrator” privilege. BC-K200 SERIES USER MANUAL Page: 4-6...
  • Page 62: Installing Vga Driver Utility

    Chapter 4 Software Utilities 4.5 Installing VGA Driver Utility The VGA interface embedded with our BC-K200 can support a wide range of display. To install the VGA Driver, simply follow the following steps: Insert the driver disk into a DVD-ROM device.
  • Page 63: Installing Lan Driver Utility

    Chapter 4 Software Utilities 4.6 Installing LAN Driver Utility BC-K200 is enhanced with LAN function that can support various network adapters. Installation programs for LAN drivers are listed as follows: For more details on Installation procedure, please refer to Readme.txt file found on LAN Driver Utility.
  • Page 64: Sound Driver Utility

    Run the application with the “Administrator” privilege. Follow the instructions on the screen to complete the installation. Once the installation is completed, shut down the system and restart it in order for the changes to take effect. BC-K200 SERIES USER MANUAL Page: 4-9...
  • Page 65: Bios Setup

    Setup information is retained when the system is powered off. The BIOS Setup Utilities consist of the following menu items: Main Menu • Advanced Menu • Chipset Menu • Security Menu • Boot Menu • Save & Exit Menu • BC-K200 SERIES USER MANUAL Page: 5-1...
  • Page 66: Introduction

    Chapter 5 BIOS Setup 5.1 Introduction The BC-K200 System uses an AMI (American Megatrends Incorporated) Aptio BIOS that is stored in the Serial Peripheral Interface Flash Memory (SPI Flash) and can be updated. The SPI Flash contains the built-in BIOS setup program, Power-On Self-Test (POST), PCI auto-configuration utility, LAN EEPROM information, and Plug and Play support.
  • Page 67: Accessing Setup Utility

    POST message will be displayed: Figure 5-2. POST Screen with AMI Logo Press <Del> or <Esc> to access the Setup Utility program and the Main menu of the Aptio Setup Utility will appear on the screen as below: BC-K200 SERIES USER MANUAL Page: 5-3...
  • Page 68 English. You may use <↑> or <↓> key to select among the items and press <Enter> to confirm and enter the sub-menu. The following table provides the list of the navigation keys that you can use while operating the BIOS setup menu. BC-K200 SERIES USER MANUAL Page: 5-4...
  • Page 69 The CMOS battery is The battery may be losing power and users should bad or has been recently replace the battery immediately. Also, this message is replaced. displayed once the new battery is replaced. BC-K200 SERIES USER MANUAL Page: 5-5...
  • Page 70: Main

    Month/ Date/ Year]. Users can directly enter values or use <+> or <-> arrow keys to increase/decrease it. The “Day” is automatically changed. System Time Hour, minute, second Sets the system time. The format is [Hour: BC-K200 SERIES USER MANUAL Page: 5-6...
  • Page 71: Advanced

    Advanced Menu Screen BIOS Setting Options Description/Purpose Trusted Computing Sub-Menu Trusted Computing Settings. ACPI Settings Sub-Menu System ACPI Parameters. PCH-FW Sub-Menu Management Engine Technology Configuration Parameters. F81866 Super IO Sub-Menu System Super IO Chip Parameters. Configuration BC-K200 SERIES USER MANUAL Page: 5-7...
  • Page 72: Advanced - Trusted Computing

    Enables or Disables BIOS support for Security Device - Enabled security device. O.S will not show security Support Device. TCG EFI protocol and INT1A interface will not be available. Security Device No changeable options Security Device Information. Status BC-K200 SERIES USER MANUAL Page: 5-8...
  • Page 73: Advanced - Acpi Settings

    SUSPEND button RAM) is pressed. Lock Legacy - Disabled Enables or Disables Lock of Legacy Resources - Enabled Resources. - Disabled S3 Video Repost Enables or Disables S3 Video Repost. - Enabled BC-K200 SERIES USER MANUAL Page: 5-9...
  • Page 74: Advanced - Pch-Fw Configuration

    Options Description/Purpose ME Firmware No changeable options Displays the ME Firmware Version. Version ME Firmware No changeable options Displays the ME Firmware Mode. Mode ME Firmware No changeable options Displays the ME Firmware SKU. BC-K200 SERIES USER MANUAL Page: 5-10...
  • Page 75: Advanced - F81866 Super Io Configuration

    Serial Port 4 Sets parameters of Serial Port 4 Sub-Menu Configuration (COMD). Serial Port 5 Sets parameters of Serial Port 5 Sub-Menu Configuration (COME). Serial Port 6 Sets parameters of Serial Port 6 Sub-Menu Configuration (COMF). BC-K200 SERIES USER MANUAL Page: 5-11...
  • Page 76 No changeable options of Serial Port 1. - Auto Selects IRQ and I/O - IO=3F8h; IRQ=4; resource settings for Serial - IO=3F8h; IRQ=3,4,5,6,7,9,10,11,12; Port 1. Change Settings - IO=2F8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-12...
  • Page 77 No changeable options of Serial Port 2. - Auto Selects IRQ and I/O - IO=2F8h; IRQ=3; resource settings for Serial - IO=3F8h; IRQ=3,4,5,6,7,9,10,11,12; Port 2. Change Settings - IO=2F8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-13...
  • Page 78 No changeable options of Serial Port 3. - Auto Selects IRQ and I/O - IO=3E8h; IRQ=10; resource settings for Serial - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; Port 3. Change Settings - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2F0h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-14...
  • Page 79 No changeable options of Serial Port 4. - Auto Selects IRQ and I/O - IO=2E8h; IRQ=5; resource settings for Serial - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; Port 4. Change Settings - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2F0h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-15...
  • Page 80 No changeable options of Serial Port 5. - Auto Selects IRQ and I/O - IO=2F0h; IRQ=7; resource settings for Serial - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; Port 5. Change Settings - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2F0h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-16...
  • Page 81 No changeable options of Serial Port 6. - Auto Selects IRQ and I/O - IO=2E0h; IRQ=6; resource settings for Serial - IO=3E8h; IRQ=3,4,5,6,7,9,10,11,12; Port 6. Change Settings - IO=2E8h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2F0h; IRQ=3,4,5,6,7,9,10,11,12; - IO=2E0h; IRQ=3,4,5,6,7,9,10,11,12; BC-K200 SERIES USER MANUAL Page: 5-17...
  • Page 82: Advanced - Hardware Monitor

    Displays the VCORE CPU voltage in VCORE No changeable options supply. Displays the voltage level of VSB5V VSB5V No changeable options in supply. Displays the voltage level of VCC5V VCC5V No changeable options in supply. BC-K200 SERIES USER MANUAL Page: 5-18...
  • Page 83 Displays the voltage level of VCC3V VCC3V No changeable options in supply. Displays the voltage level of VSB3V VSB3V No changeable options in supply. Displays the voltage level of VSB5V VSB5V No changeable options in supply. BC-K200 SERIES USER MANUAL Page: 5-19...
  • Page 84: Advanced - Smart Fan Mode Configuration

    Fan1 Control - Auto Duty-Cycle Mode fan 1. Manual Duty Mode - Numeric Manual mode fan control. Users can (from 1 to 100) write the expected duty cycle (PWM fan type) from 1 to 100. BC-K200 SERIES USER MANUAL Page: 5-20...
  • Page 85: Advanced - F81866 Watchdog Configuration

    Selects 1s (second) or 60s (minute) as Watchdog timer unit - 60s the time unit of Watchdog timer. Count for Timer Numeric Sets the timeout for Watchdog timer. (Seconds) (from 1 to 255) (Max. value: 255 seconds or minutes) BC-K200 SERIES USER MANUAL Page: 5-21...
  • Page 86: Advanced - Cpu Configuration

    L4 Cache No changeable options L4 Cache Size CPU VMX hardware support for No changeable options virtual machines. SMX/TXT No changeable options Secure Mode extensions or TXT (LT) support. TXT stands for Trusted Execution Technology. BC-K200 SERIES USER MANUAL Page: 5-22...
  • Page 87 Enables/Disables Software Guard (SGX) - Enabled Extensions (SGX) Hyper-Threading - Disabled Enabled for Windows XP and Linux - Enabled (OS optimized for Hyper-Threading Technology) and Disabled for other OS (OS not optimized for Hyper-Threading Technology). BC-K200 SERIES USER MANUAL Page: 5-23...
  • Page 88: Advanced - Sata Configuration (Ahci Mode)

    Indicates whether the connected options SATA device supports Software Setting Preservation (SSP). Port 0-3 for H110 sku. - Disabled Enables or Disables SATA Port Port 0-5 for Q170 sku. - Enabled Device. Port 0-7 for C236 sku. BC-K200 SERIES USER MANUAL Page: 5-24...
  • Page 89 Chapter 5 BIOS Setup BIOS Setting Options Description/Purpose Hot Plug - Disabled Enables or Disables Hot Plug - Enabled function to designate a SATA port device as hot-pluggable. BC-K200 SERIES USER MANUAL Page: 5-25...
  • Page 90: Advanced - Network Stack Configuration

    Support - Enabled disabled, IPv4 PXE boot option will not be created. Ipv4 HTTP - Disabled Enables/Disables IPv4 HTTP boot Support - Enabled support. If disabled, IPv4 HTTP boot support will not be available. BC-K200 SERIES USER MANUAL Page: 5-26...
  • Page 91 Number of seconds to wait for PXE boot Numeric (from 0 to 5) time to abort after the Esc key is pressed. Media detect Number of times that the media presence Numeric (from 1 to 50) count will be checked. BC-K200 SERIES USER MANUAL Page: 5-27...
  • Page 92: Advanced - Usb Configuration

    The USB Configuration allows users to enable/disable USB mass storage driver support. USB Configuration Screen BIOS Setting Options Description/Purpose USB Mass Storage Driver - Disabled Enables/Disables USB mass storage driver Support - Enabled support. BC-K200 SERIES USER MANUAL Page: 5-28...
  • Page 93: Chipset

    This menu allows users to configure advanced Chipset settings such as System Agent (SA) and PCH-IO configuration parameters. Chipset Screen BIOS Setting Options Description/Purpose System Agent (SA) Sub-Menu System Agent (SA) parameters. Configuration PCH-IO Configuration Sub-Menu PCH parameters. BC-K200 SERIES USER MANUAL Page: 5-29...
  • Page 94: Chipset - System Agent (Sa) Configuration

    I/O devices in virtualized environment. Memory Displays the DRAM information on the Sub-Menu Configuration platform. BC-K200 SERIES USER MANUAL Page: 5-30...
  • Page 95 Chapter 5 BIOS Setup BIOS Setting Options Description/Purpose Graphics Sub-Menu Configures Graphics configurations. Configuration PEG Port Configuration Sub-Menu PEG Port Configuration. (PCI_E1) - Disabled VT-d Enables or Disables VT-d function. - Enabled BC-K200 SERIES USER MANUAL Page: 5-31...
  • Page 96: Chipset - Graphics Configuration

    Primary Display or selects - PEG SG for Switchable Gfx. - PCIE Internal Graphics - Auto Keeps IGFX enabled based on the setup - Disabled options. - Enabled LCD Control Sub-Menu LCD Control sub-menu. BC-K200 SERIES USER MANUAL Page: 5-32...
  • Page 97 Description/Purpose Primary IGFX - VBIOS Default Selects Primary Display device. Boot Display - DisplayPort - VGA - DVI Secondary IGFX - Disabled Selects Secondary Display device. Boot Display - DisplayPort - VGA - DVI BC-K200 SERIES USER MANUAL Page: 5-33...
  • Page 98: Chipset - Sa Configuration > Peg Port Configuration

    - Auto - Auto Configures PEG 0:1:0 maximum speed. - Gen 1 Max Link Speed - Gen 2 - Gen 3 Detect - Disabled Detects Non-Compliance PCI Express Non-Compliance - Enabled Device in PEG. Device BC-K200 SERIES USER MANUAL Page: 5-34...
  • Page 99: Chipset - Sa Configuration > Memory Configuration

    Displays the information of Channel 1 No changeable options Q170 and C236 sku. Slot 0. Channel 1 Slot 1 for Displays the information of Channel 1 No changeable options Q170 and C236 sku. Slot 1. BC-K200 SERIES USER MANUAL Page: 5-35...
  • Page 100: Chipset - Pch-Io Configuration

    Enables or Disables integrated LAN to Enable - Enabled wake up the system. Specifies what state to go to when power - Power On State After G3 is re-applied following a power failure - Power Off (G3 state). BC-K200 SERIES USER MANUAL Page: 5-36...
  • Page 101: Chipset - Pci Express Configuration

    Configures PCI Express Root Sub-Menu Port 7 settings. (PCI_E3) PCI Express Root Port 9 Configures PCI Express Root Sub-Menu Port 9 settings. (PCI_E2) Mini-PCI Express Root Configures Mini-PCI Express Sub-Menu Port 1 Root Port 1 settings. BC-K200 SERIES USER MANUAL Page: 5-37...
  • Page 102 - L1 mode that activates when the bus is - L0sL1 not being used. - Auto Force L0s – Force all links to L0s State Auto – BIOS Auto configure Disable – Disables ASPM BC-K200 SERIES USER MANUAL Page: 5-38...
  • Page 103 - Gen2 - Gen3 Detect Non-Compliance Device Detects a Non-Compliance PCI - Disabled Express device that is connected to - Enabled the PCI Express port. If enabled, it will take more time during POST. BC-K200 SERIES USER MANUAL Page: 5-39...
  • Page 104 - L1 mode that activates when the bus is - L0sL1 not being used. - Auto Force L0s – Force all links to L0s State Auto – BIOS Auto configure Disable – Disables ASPM BC-K200 SERIES USER MANUAL Page: 5-40...
  • Page 105 - Gen2 - Gen3 Detect Non-Compliance Device Detects a Non-Compliance PCI - Disabled Express device that is connected to - Enabled the PCI Express port. If enabled, it will take more time during POST. BC-K200 SERIES USER MANUAL Page: 5-41...
  • Page 106 - L1 mode that activates when the bus is - L0sL1 not being used. - Auto Force L0s – Force all links to L0s State Auto – BIOS Auto configure Disable – Disables ASPM BC-K200 SERIES USER MANUAL Page: 5-42...
  • Page 107 - Gen2 - Gen3 Detect Non-Compliance Device Detects a Non-Compliance PCI - Disabled Express device that is connected to - Enabled the PCI Express port. If enabled, it will take more time during POST. BC-K200 SERIES USER MANUAL Page: 5-43...
  • Page 108 Force L0s – Force all links to L0s State - Auto Auto – BIOS Auto configure Disable – Disables ASPM L1 Substates - Disabled PCI Express L1 Substates settings. - L1.1 - L1.2 - L1.1 & L1.2 BC-K200 SERIES USER MANUAL Page: 5-44...
  • Page 109 - Gen3 Detect Non-Compliance - Disabled Detects a Non-Compliance PCI Express Device device that is connected to the Mini PCI - Enabled Express root port. If enabled, it will take more time during POST. BC-K200 SERIES USER MANUAL Page: 5-45...
  • Page 110: Security

    Setup utility. Security Screen BIOS Setting Options Description/Purpose Administrator Password Password can be 3-20 Specifies the administrator alphanumeric characters. password. User Password Password can be 3-20 Specifies the user password. alphanumeric characters. BC-K200 SERIES USER MANUAL Page: 5-46...
  • Page 111 <Enter>, and the password dialog entry box appears. Select the configured Administrator Password or User Password that you want to delete. Leave the dialog box blank and press <Enter>. Press <Enter> again when the password confirmation box appears. BC-K200 SERIES USER MANUAL Page: 5-47...
  • Page 112: Boot

    Bootup NumLock State - On (default) Selects the NumLock state after the - Off system is powered on. • On: Enables the NumLock function automatically after the system is powered on. • Off: Disables the NumLock BC-K200 SERIES USER MANUAL Page: 5-48...
  • Page 113 Sets the system boot order. - Disabled Hard Drive BBS Priorities Sub-Menu Defines the boot order for all the hard drives connected to the system, e.g. SATA, USB drive. CSM Configuration Sub-Menu Configures CSM parameters. BC-K200 SERIES USER MANUAL Page: 5-49...
  • Page 114 USB storage. Press Enter to enter the sub-menu and press <↑> or <↓> arrow keys to select the device. Another way is to press <+> or <-> to move the selected device up/down in the priority list. BC-K200 SERIES USER MANUAL Page: 5-50...
  • Page 115: Boot - Csm Configuration

    Enables or Disables CSM Support. - Enabled CSM16 Module No changeable options Displays the CSM 16 Module version. Version Boot option filter - UEFI and Legacy This option controls Legacy/UEFI ROMs - Legacy only priority. - UEFI only BC-K200 SERIES USER MANUAL Page: 5-51...
  • Page 116 Controls the execution of UEFI and - UEFI Legacy Video Option ROM. - Legacy Other PCI - Do not launch Determines Option ROM execution policy devices - UEFI for devices other than Network, Storage or - Legacy Video. BC-K200 SERIES USER MANUAL Page: 5-52...
  • Page 117: Save & Exit

    Discard Changes and Reset to discard any changes you have made and restore the factory BIOS defaults. Load User Defaults You may simply press F3 at any time to load the Optimized Values which resets all BIOS settings to the factory defaults. Save & Exit Screen BC-K200 SERIES USER MANUAL Page: 5-53...
  • Page 118 Save the changes done so far as User Save as User Defaults No changeable options Defaults. Restore the User Defaults to all the Restore User Defaults No changeable options setup options. Forces to boot from selected Boot Override - [Drive(s)] [drive(s)]. BC-K200 SERIES USER MANUAL Page: 5-54...
  • Page 119: Appendix A System Diagrams

    BC-K200 system. The following topics are included: BC-K200 System Exploded Diagram • BC-K200 System Fan Assembly Exploded Diagram • BC-K200 DVD & 3.5” HDD Module Assembly • Exploded Diagram BC-K200 DVD & 2.5” HDD Module Assembly • Exploded Diagram BC-K200 3.5”...
  • Page 120 Appendix A System Diagrams BC-K200 System Exploded Diagram BC-K200 SERIES USER MANUAL Page: A-2...
  • Page 121 Appendix A System Diagrams Component Name P/N No. Q’ty BC-K200 BOT CASE PWS IO PLATE KIT 20-104-03061498 FOR TEL(w/Paint)(Black) FAN_FIXED_FRAME_PLATE_ASSY_EXP See Page A-4 FLAT HEAD SCREW #2 / M3x0.5Px5mm 22-215-30005011 HEX CU BOSS M3x0.5Px3L,H=5mm 22-290-30005051 BU-2509 Main PCB ASSY See Page A-10...
  • Page 122: Bc-K200 System Fan Assembly Exploded Diagram

    Appendix A System Diagrams BC-K200 System Fan Assembly Exploded Diagram 2 16X 1 2X Component Name P/N No. Q’ty KT-7290 SYSTEM FAN (80x80x20mm) 21-004-08080134 L=300mm FLAT HEAD SCREW #2 / T4.7x11mm 82-712-47011018 BC-K200 FAN FIXED FRAME PLATE 20-104-03062498 (w/Paint)(Black) Fan_holder_for_80-80...
  • Page 123: Bc-K200 Dvd & 3.5" Hdd Module Assembly Exploded Diagram

    Appendix A System Diagrams BC-K200 DVD & 3.5” HDD Module Assembly Exploded Diagram 5 4X Component Name P/N No. Q’ty BC-K200 DVD HDD HOLDER (w/Paint) (Black) 20-129-03061498 DVD Player FILLISTER HEAD SCREW M2x0.4Px2.5mm 22-272-20002011 HDD_3.5inch_SATA_STAND_RUBBER_KIT_ See Page A-7 WASHER (OD=Φ10mm,ID=Φ3mmx0.8T) 23-312-30080101 TRUSS HEAD SCREW M3x0.5Px6mm...
  • Page 124: Bc-K200 Dvd & 2.5" Hdd Module Assembly Exploded Diagram

    Appendix A System Diagrams BC-K200 DVD & 2.5” HDD Module Assembly Exploded Diagram 5 4X Component Name P/N No. Q’ty BC-K200 DVD HDD HOLDER(w/Paint)(Black) 20-129-03061498 DVD Player FILLISTER HEAD SCREW M2x0.4Px2.5mm 22-272-20002011 HDD_2.5inch_DOUBLE_SATA_STAND_ See Page A-8 RUBBER_KIT_EXP WASHER (OD=Φ10mm,ID=Φ3mmx0.8T) 23-312-30080101 TRUSS HEAD SCREW M3x0.5Px6mm...
  • Page 125: Bc-K200 3.5" Hdd Module Assembly Exploded Diagram

    Appendix A System Diagrams BC-K200 3.5” HDD Module Assembly Exploded Diagram 3 4X Component Name P/N No. Q’ty HDD Module BC-K200 3.5INCH HDD STAND (w/Paint)(Black) 20-117-03062498 PAN HEAD SCREW UNC-No.6-32, L=5mm 22-622-60005011 BC-B015 SHOCK ABSORB RUBBER (Black) 90-013-01100498 BC-K200 SERIES USER MANUAL...
  • Page 126: Bc-K200 2.5" Hdd Module Assembly Exploded Diagram

    Appendix A System Diagrams BC-K200 2.5” HDD Module Assembly Exploded Diagram 2 2X Component Name P/N No. Q’ty HDD_25_H7_SEAGATE_SATA SE-8210 SATA HDD & POWER CABLE 27-008-26105082 L=240mm BC-K200 2.5INCH DOUBLE HDD 20-117-03061498 STAND(w/Paint)(Black) BC-B015 SHOCK ABSORB RUBBER(Black) 90-013-01100498 FILLISTER HEAD SCREW #2 / M3x0.5Px5mm 22-272-30049015 BC-K200 2.5”...
  • Page 127: Bc-K200 Riser Card Assembly Exploded Diagram

    Appendix A System Diagrams BC-K200 Riser Card Assembly Exploded Diagram 5 2X Component Name P/N No. Q’ty BR-2509-1_ASM ROUND WASHER HEAD SCREW 22-242-30005311 (M3x0.5Px5mm) BR-2509-3_ASM BR-2509-2_ASM PDS-8080 IO BRACKET 80-006-21001006 BC-K200 RISER EXPAND CARD HOLDER 20-129-03062498 KIT(w/Paint)(Black) USB CABLE (WITH BRACKET) (USBx2 to 27-006-49806111 10F/P2.0) L=300mm...
  • Page 128: Bc-K200 Main Board I/O Shield Assembly Exploded Diagram

    Appendix A System Diagrams BC-K200 Main Board I/O Shield Assembly Exploded Diagram Component Name P/N No. Q’ty BU-2509_MAIN_PCB_ASSY HEX CU BOSS UNC No.4-40,L=5,H=6mm 22-392-40005301 BK-0940 IO SHIELD 80-010-07001357 BC-K200 SERIES USER MANUAL Page: A-10...
  • Page 129: Bc-K200 Rack Mount Holder Assembly Exploded Diagram

    Appendix A System Diagrams BC-K200 Rack Mount Holder Assembly Exploded Diagram 3 2X Component Name P/N No. Q’ty BC-K200 RACK MOUNT HOLDER 20-229-03061498 (w/Paint)(Black) ALUMINUM HANDLE 20-035-01001000 FLAT HEAD SCREW #2/M5x0.8Px8mm 22-215-50008011 BC-K200 SERIES USER MANUAL Page: A-11...
  • Page 130: Appendix B Technical Summary

    Appendix B Technical Summary This appendix will give you a brief introduction of the allocation maps for BC-K200 resources. The following topics are included: • Block Diagram • Interrupt Map • I/O Map • Memory Map • Configuring Watchdog Timer •...
  • Page 131: Block Diagram

    ALC 888S-VD2 High Definition Codec SPI FLASH ROM LOW PIN COUNT 80 PORT for Debug COM 1/3/4/5/6 RS232 FINTEK Connector COM3/4 support 5V/12V LPC SIO HW monitor COM 2 F81866AD-I RS232/422/485 PS/2 Keyboard Mouse BC-K200 SERIES USER MANUAL Page: B-2...
  • Page 132: Interrupt Map

    IRQ 86 Microsoft ACPI-Compliant System IRQ 87 Microsoft ACPI-Compliant System IRQ 88 Microsoft ACPI-Compliant System IRQ 89 Microsoft ACPI-Compliant System IRQ 90 Microsoft ACPI-Compliant System IRQ 91 Microsoft ACPI-Compliant System IRQ 92 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-3...
  • Page 133 IRQ 115 Microsoft ACPI-Compliant System IRQ 116 Microsoft ACPI-Compliant System IRQ 117 Microsoft ACPI-Compliant System IRQ 118 Microsoft ACPI-Compliant System IRQ 119 Microsoft ACPI-Compliant System IRQ 120 Microsoft ACPI-Compliant System IRQ 121 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-4...
  • Page 134 IRQ 144 Microsoft ACPI-Compliant System IRQ 145 Microsoft ACPI-Compliant System IRQ 146 Microsoft ACPI-Compliant System IRQ 147 Microsoft ACPI-Compliant System IRQ 148 Microsoft ACPI-Compliant System IRQ 149 Microsoft ACPI-Compliant System IRQ 150 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-5...
  • Page 135 IRQ 173 Microsoft ACPI-Compliant System IRQ 174 Microsoft ACPI-Compliant System IRQ 175 Microsoft ACPI-Compliant System IRQ 176 Microsoft ACPI-Compliant System IRQ 177 Microsoft ACPI-Compliant System IRQ 178 Microsoft ACPI-Compliant System IRQ 179 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-6...
  • Page 136 IRQ 266 Microsoft ACPI-Compliant System IRQ 267 Microsoft ACPI-Compliant System IRQ 268 Microsoft ACPI-Compliant System IRQ 269 Microsoft ACPI-Compliant System IRQ 270 Microsoft ACPI-Compliant System IRQ 271 Microsoft ACPI-Compliant System IRQ 272 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-7...
  • Page 137 IRQ 295 Microsoft ACPI-Compliant System IRQ 296 Microsoft ACPI-Compliant System IRQ 297 Microsoft ACPI-Compliant System IRQ 298 Microsoft ACPI-Compliant System IRQ 299 Microsoft ACPI-Compliant System IRQ 300 Microsoft ACPI-Compliant System IRQ 301 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-8...
  • Page 138 IRQ 324 Microsoft ACPI-Compliant System IRQ 325 Microsoft ACPI-Compliant System IRQ 326 Microsoft ACPI-Compliant System IRQ 327 Microsoft ACPI-Compliant System IRQ 328 Microsoft ACPI-Compliant System IRQ 329 Microsoft ACPI-Compliant System IRQ 33 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-9...
  • Page 139 IRQ 353 Microsoft ACPI-Compliant System IRQ 354 Microsoft ACPI-Compliant System IRQ 355 Microsoft ACPI-Compliant System IRQ 356 Microsoft ACPI-Compliant System IRQ 357 Microsoft ACPI-Compliant System IRQ 358 Microsoft ACPI-Compliant System IRQ 359 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-10...
  • Page 140 IRQ 382 Microsoft ACPI-Compliant System IRQ 383 Microsoft ACPI-Compliant System IRQ 384 Microsoft ACPI-Compliant System IRQ 385 Microsoft ACPI-Compliant System IRQ 386 Microsoft ACPI-Compliant System IRQ 387 Microsoft ACPI-Compliant System IRQ 388 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-11...
  • Page 141 IRQ 411 Microsoft ACPI-Compliant System IRQ 412 Microsoft ACPI-Compliant System IRQ 413 Microsoft ACPI-Compliant System IRQ 414 Microsoft ACPI-Compliant System IRQ 415 Microsoft ACPI-Compliant System IRQ 416 Microsoft ACPI-Compliant System IRQ 417 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-12...
  • Page 142 IRQ 440 Microsoft ACPI-Compliant System IRQ 441 Microsoft ACPI-Compliant System IRQ 442 Microsoft ACPI-Compliant System IRQ 443 Microsoft ACPI-Compliant System IRQ 444 Microsoft ACPI-Compliant System IRQ 445 Microsoft ACPI-Compliant System IRQ 446 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-13...
  • Page 143 IRQ 469 Microsoft ACPI-Compliant System IRQ 470 Microsoft ACPI-Compliant System IRQ 471 Microsoft ACPI-Compliant System IRQ 472 Microsoft ACPI-Compliant System IRQ 473 Microsoft ACPI-Compliant System IRQ 474 Microsoft ACPI-Compliant System IRQ 475 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-14...
  • Page 144 IRQ 498 Microsoft ACPI-Compliant System IRQ 499 Microsoft ACPI-Compliant System IRQ 500 Microsoft ACPI-Compliant System IRQ 501 Microsoft ACPI-Compliant System IRQ 502 Microsoft ACPI-Compliant System IRQ 503 Microsoft ACPI-Compliant System IRQ 504 Microsoft ACPI-Compliant System BC-K200 SERIES USER MANUAL Page: B-15...
  • Page 145 Microsoft ACPI-Compliant System IRQ 509 Microsoft ACPI-Compliant System IRQ 510 Microsoft ACPI-Compliant System IRQ 511 Microsoft ACPI-Compliant System Note: These resource information were gathered using Windows 10 (the IRQ could be assigned differently depending on OS). BC-K200 SERIES USER MANUAL Page: B-16...
  • Page 146: I/O Map

    0x00000A20-0x00000A2F Motherboard resources 0x0000002E-0x0000002F Motherboard resources 0x0000004E-0x0000004F Motherboard resources 0x00000061-0x00000061 Motherboard resources 0x00000063-0x00000063 Motherboard resources 0x00000065-0x00000065 Motherboard resources 0x00000067-0x00000067 Motherboard resources 0x00000080-0x00000080 Motherboard resources 0x00000092-0x00000092 Motherboard resources 0x000000B2-0x000000B3 Motherboard resources 0x00000680-0x0000069F Motherboard resources 0x00001800-0x000018FE Motherboard resources BC-K200 SERIES USER MANUAL Page: B-17...
  • Page 147 Programmable interrupt controller 0x00000038-0x00000039 Programmable interrupt controller 0x0000003C-0x0000003D Programmable interrupt controller 0x000000A0-0x000000A1 Programmable interrupt controller 0x000000A4-0x000000A5 Programmable interrupt controller 0x000000A8-0x000000A9 Programmable interrupt controller 0x000000AC-0x000000AD Programmable interrupt controller 0x000000B0-0x000000B1 Programmable interrupt controller 0x000000B2-0x000000B3 Programmable interrupt controller BC-K200 SERIES USER MANUAL Page: B-18...
  • Page 148 Appendix B Technical Summary I/O MAP ASSIGNMENT 0x000000B4-0x000000B5 Programmable interrupt controller 0x000000B8-0x000000B9 Programmable interrupt controller 0x000000BC-0x000000BD Programmable interrupt controller 0x000004D0-0x000004D1 Programmable interrupt controller 0x00000040-0x00000043 System timer 0x00000050-0x00000053 System timer BC-K200 SERIES USER MANUAL Page: B-19...
  • Page 149 0xDF730000-0xDF73FFFF Intel USB 3.0 eXtensible Host Controller ® 0xDF740000-0xDF743FFF High Definition Audio Controller 0xDF744000-0xDF747FFF Intel 100 Series Chipset Family PMC ® 0xDF748000-0xDF749FFF Standard SATA AHCI Controller 0xDF74A000-0xDF7470FF Intel 100 Series Chipset Family SMBus ® BC-K200 SERIES USER MANUAL Page: B-20...
  • Page 150: Memory Map

    Motherboard resource 0xFED00000-FED003FF Motherboard resource 0xFE000000-FE01FFFF High precision event timer 0xFED10000-FED17FFF Motherboard resource 0xFED18000-FED18FFF Motherboard resource 0xFED19000-FED19FFF Motherboard resource 0xFED20000-FED3FFFF Motherboard resource 0xFED45000-FED8FFFF Motherboard resource 0xFED90000-FED93FFF Motherboard resource 0xFEE00000-FEEFFFFF Motherboard resource 0xFF000000-FFFFFFFF Motherboard resource BC-K200 SERIES USER MANUAL Page: B-21...
  • Page 151 Appendix B Technical Summary MEMORY MAP ASSIGNMENT 0xFF000000-FFFFFFFF Intel 82802 Firmware Hub Device ® 0xFF000000-FFFFFFFF Intel 82802 Firmware Hub Device ® BC-K200 SERIES USER MANUAL Page: B-22...
  • Page 152 To exit the Extended Function Mode, writing 0xAA to the EFER is required. Once the chip exits the Extended Function Mode, it is in the normal running mode and is ready to enter the configuration mode. BC-K200 SERIES USER MANUAL Page: B-23...
  • Page 153 ;---------------------------------Enable Watch dog feature ---------------------------------------------- 030h ;------------------------------- Enable Watch PME-------------------------------------------------------- 0FAh ;-------------------------- Set second as counting unit -------------------------------------------------- 0f5h ; ---------------- Set timeout interval as 30seconds and start counting ----------------------- 0f6h ;---------------------------------Exit the extended function mode -------------------- 0aah BC-K200 SERIES USER MANUAL Page: B-24...
  • Page 154 (3) The system will go into the BIOS setup menu. (4) Select [Boot] menu and enter into [CSM Configuration] menu. (5) Set [Boot option filter] to [UEFI Only] and press <F4> key to save configuration and restart the system. BC-K200 SERIES USER MANUAL Page: B-25...
  • Page 155 (6) Press <ESC> or <DEL> to enter into BIOS setup menu again. (7) Select [Boot] menu and set [UEFI: Built-in EFI Shell] as the boot device. (8) Press <F4> key to save the configuration and restart the system to boot into EFI Shell environment. BC-K200 SERIES USER MANUAL Page: B-26...
  • Page 156 /?” to see all the definition of each control option. The recommended options for BIOS ROM update include the following parameters: Program main BIOS image. /B: Program Boot Block. /N: Program NVRAM. /X: Don’t check ROM ID. BC-K200 SERIES USER MANUAL Page: B-27...
  • Page 157 BIOS ROM and make the system unable to boot up next time. After BIOS update procedure is completed, the following picture will display: BC-K200 SERIES USER MANUAL Page: B-28...
  • Page 158 Restart the system and boot up with the new BIOS configurations. The BIOS Update is completed after the system is restarted. Reboot the system and verify if the BIOS version shown on the initialization screen has been updated. BC-K200 SERIES USER MANUAL Page: B-29...

Table of Contents