Page 1
Instruments and Systems for Geotechnical and Structural Monitoring Portable Electronic Telependulum Instruction and User Manual Pizzi Instruments S.r.l. Strumenti e Sistemi per il Monitoraggio Geotecnico e Strutturale Via del Fornaccio, 46 – 50012 Bagno a Ripoli - Firenze, Italia Tel/Fax 0039 0556810722 email: info@pizzi-instruments.it, web: www.pizzi-instruments.it...
Page 2
Pizzi Instruments S.r.l. reserves the right to change the information contained in this document without notice. No part of this document may be reproduced without the prior written consent of Pizzi Instruments S.r.l . The instruments supplied by Pizzi Instruments S.r.l. are designed and optimized to be used and installed with simplicity.
Page 3
Customer shall assume all the costs of removing and shipping defective products to Pizzi Instruments S.r.l. and the costs of reinstalling the repaired/substituted instruments. The foregoing warranty shall not apply to any Pizzi Instruments S.r.l. products which have been subjected to modification, misuse, misapplication, neglect, improper service or maintenance, accidents of nature, improper installation.
Use of this manual This manual must be considered for the installation and use of the manual coordinometer – EGS Model. Dangers and safety Warning for the unpacking of the material: Be careful when handling the packaging to avoid damage to property and / or people.
Please check if all received items correspond with the packing list, your order confirmation and if the list of components (chapter 4.1) corresponds to the material effectively present. In case of discrepancy, please contact Pizzi Instruments or your local Representative. 2.1 Damage during shipment If requested at the moment of the order, all instruments can be insured prior to shipment.
Manual Procedure 4.2 Measuring System The manual coordinometer – EGS Model is a reading instrument for the monitoring of direct and inverted pendulums . This instrument allows to execute, manually, the reading of the horizontal movements of the plumb wire.
In GREEN colour is represented the automatic coordinometer In BLACK colour is represented the support plate of the manual coordinometer model EGS-2C In BLUE colour is represented the caisson of the inverted pendulum Instruction Manual / Portable Electronic Telependulum – EGS Model REV02 / 15.01.2014...
6 Operating Instructions 6.1 Reaing Manual Device To set up the EGS-2C unit for taking measurements, you have to proceed as follows : 1)Press the button ON to set up the unit in STAND-BY; the display will instantly visualize the following mask: ...
Page 11
Once achieved the 3rd passage, the display will visualize the SC1 and SC2 measurements, expressed in millimeters. In case you wish to repeat the measurement, press RESET and start a new cycle as described in point n.6. Instruction Manual / Portable Electronic Telependulum – EGS Model REV02 / 15.01.2014...
AVANTI of the movable group, as showed by the procedure. If the movable group position is not correct, the display will visualize the following mask : Instruction Manual / Portable Electronic Telependulum – EGS Model REV02 / 15.01.2014...
Page 13
The self switching-off The test unit has a temporized POWER – OFF procedure, that occurs after 20’ from the last measuring operation executed with the instrument. EGS-2C Instruction Manual / Portable Electronic Telependulum – EGS Model REV02 / 15.01.2014 Pag. 13/15...
Manual Procedure 6.3 Technical Assistance Pizzi Instruments S.r.l. has a wide range of service as phone assistance, installation, training, calibration, reparation and maintenance. For any additional information you can directly contact our technicians at the following address tec@pizzi-instruments.it Phone/fax : 0039/055/6810722 7 Maintenance The unit needs a particular care, as it is a measuring instrument qualified for executing precision checks.
Need help?
Do you have a question about the EGS and is the answer not in the manual?
Questions and answers