  • Page 1 65 Camera dol-sensors a/s – Agro Food Park 15 – DK-8200 Aarhus N – T: +45 7217 5888 – F: +45 7217 5959 – www.dol-sensors.com...
  • Page 2: Product Description

    1 Product description iDOL 65 calculates the weight of the finishers. iDOL 65 uses a camera to calculate the weight based on the size of the pig, i.e. height, width, length. iDOL 65 Weighing precision has been tested and verified on piglets and pigs for slaughter in the weight range from 7-110 kg in breeding species DanBred.
  • Page 3: Product Survey

    2 Product survey 140324 iDOL 65 camera iDOL 65 camera calculates the weight of slaughter pigs. iDOL 65 uses a 3d camera to calculate the weight based on the size of the pig. Supplied with plastic glands, sealing plugs, split seals, and mounting bracket screws.
  • Page 4 3 Mounting iDOL 65 must be placed at an exact height and relative to the housing equipment in the pen, next to the feed dispenser at dry feeding and next to the drinking nipple at wet feeding. The minimum ceiling height is 2390 mm, there must be no pipes, wires, or anything else that can block the field of view of iDOL 65.
  • Page 5 Criteria for correct iDOL 65 installation. No.: Description: Value: Tolerance The box front must be facing the pen floor. 0° +/- 4° The camera must be hung horizontally, parallel to the floor. Height above the floor (measured from the front of the box)
  • Page 6 The iDOL 65 mounting bracket is mounteusing the screws supplied. Figure 3: iDOL 65 mounting brackets. Figure 4: Mounting example For correct mounting height and stability, mounting kit iDOL 65 can be used. Figure 5: Example of mounting with iDOL 65 mounting kit www.dol-sensors.com iDOL 65 Camera...
  • Page 7: Electrical Connection

    • LAN 1 is used in the direction of the router. • LAN 2 is used for the subsequent iDOL 65 in the ”series”. Note: If one iDOL 65 is offline for a while, data will be sent to the cloud when the iDOL 65 is back online. www.dol-sensors.com...
  • Page 8: Cable Plan

    65 must be able to communicate with the following endpoints (outgoing communication) for the camera to function properly. Description DNS / IP Port Protocol 8883 IOT Hub dol-DigitalServices-Omni-Production-IoTHub.azure- devices.net/* global.azure-devices-provisioning.net/* Google DNS 8.8.4.4 and 8.8.8.8 Device Registration https://dol-provisioning-prod.azurewebsites.net/api/ provisioning/* Blob Storage https://dolfirmware.blob.core.windows.net/*...
  • Page 9 Started / connected to cloud Firmware update ongoing Flashing quickly LAN 1 / LAN 2 LED is ON/flashes when there is an active connection through the network to another unit, for example, an iDOL 65 or a router. www.dol-sensors.com iDOL 65 Camera...
  • Page 10: Maintenance

    6 Maintenance iDOL 65 must be cleaned at a minimum after each batch or as needed, as dust and flies, etc. can block the camera's field of view (resulting in blurred images and thus fewer weighing). LED error 1 lights up solid red when the camera cannot make weighing and cleaning is required.
  • Page 11: Technical Data

    This product contains a Class 1 Laser unit under the EN/IEC 60825-1, Edition 3 (2014) interna- tionally. The laser unit complies with FDA performance standards for laser products except for confor- mance with IEC 60825-1 Ed. 3 as described in Laser Notice No. 56, dated May 8, 2019. 9.1.2. www.dol-sensors.com iDOL 65 Camera...
  • Page 12 8 Dimensions Dimensions in mm. dol-sensors a/s – Agro Food Park 15 – DK-8200 Aarhus N – T: +45 7217 5888 – F: +45 7217 5959 – www.dol-sensors.com...

Table of Contents