Installation - Curtis 1604 Manual

Switch mode battery chargers for lead-acid batteries

Advertisement

3
page 4
3. Restart: If the battery self-discharges below 12.9V for 12V batteries or below
25.7V for 24V batteries while the charger is in standby, the charger cycles into a
constant current of 1.0A (4A models)/2.0A (8A models) until the constant
voltage setpoint is reached. The unit will regulate and terminate as in Constant
Voltage Mode.
2.8 Indication Lights
The charger features built in diagnostics. Refer to the table below to interpret the
flashing of the yellow and green indicator lights. Flashing of the yellow indicator
means that the charging cycle has ended early and the battery may not be fully
charged. Refer to the Troubleshooting section to correct these faults.
Flash Pattern
Yellow on
Green on
Green blinking
Yellow & Green on simultaneously
Yellow & Green blink simultaneously
Yellow blinks 1X
Yellow blinks 2X
Yellow blinks 3X
Yellow blinks 4X
Yellow blinks 5X
Charger should be securely mounted on a flat surface.
The power cord to the IEC 320/C14 connector should be of the appropriate
gauge to carry a 10A current @ 120VAC, or a 5A current @ 230VAC for
the cable's length, to meet the requirements of applicable electrical codes.
A minimum of 30mm clearance should be provided at each end of the
charger for vented models.
The charger should not be installed in locations which restrict air flow.
Indication
AC power present
Charge complete
Charging
Charger in standby mode
No battery/reverse polarity
Not reaching constant voltage setpoint
Not reaching 24V within 2 hours
Charge current/voltage does not normalize
Battery voltage too high (over 32V)
Charger over temperature

INSTALLATION

Curtis 1604/08 Manual