Download Print this page

DONG IL TECHNOLOGY ASG-PG Series Instruction Manual

Slim ion bar

Advertisement

Quick Links

Instruction Manual
SLIM ION BAR
ASG-PG Series
Read this instruction manual before using the product in order to achieve maximum performance.
Keep this instruction manual within your reach after reading so that it can be used at any time.
28, Namyang-ro 930beon-gil, Hwaseong-si, Gyeonggi-do, Korea
Tel 82.31.299.5453 Fax 82.31.357.2610

Advertisement

loading
Need help?

Need help?

Do you have a question about the ASG-PG Series and is the answer not in the manual?

Questions and answers

Summary of Contents for DONG IL TECHNOLOGY ASG-PG Series

  • Page 1 Instruction Manual SLIM ION BAR ASG-PG Series Read this instruction manual before using the product in order to achieve maximum performance. Keep this instruction manual within your reach after reading so that it can be used at any time. 28, Namyang-ro 930beon-gil, Hwaseong-si, Gyeonggi-do, Korea...
  • Page 2 DONG IL TECHNOLOGY LTD CONTENTS 1. Product Introduction 03Page 1.1 Features 1.2 Specification 1.3 Dimensions 1.4. Performance 1.5 Package contents 1.6 Part names 1.7 Cautions and warranty 2. Installation & Connection 08Page 2.1 Installation location 2.2 Purging and moving into CR 2.3 Wiring diagram...
  • Page 3 DONG IL TECHNOLOGY LTD 1.1 Features Welcome to become a customer of DIT! ASG-PG Series is a slim bar ionizer for 250mmand 300mm lengths that could not be supported by ASG-P series by maintaining the performance of ASG-P. ASG-PG Series is, ...
  • Page 4 DONG IL TECHNOLOGY LTD DONG IL TECHNOLOGY LTD 1. 3 Dimensions...
  • Page 5 DONG IL TECHNOLOGY LTD 1.4 Performance ※ Discharge time: the time necessary for static elimination  Relation between discharge time and distance(Distance: mm, discharge Time: sec) shows discharge time according to the distance measured in product’s side and front perspective.
  • Page 6 DONG IL TECHNOLOGY LTD 1.5 Package Contents  Package ① Main body(controller & power supply embedded) ② Support brackets and screws ③ Power cable (4PIN) ※ Contact to the seller for customizing ※ Length: 3M  Options ① Ion emitter Kit ②...
  • Page 7 DONG IL TECHNOLOGY LTD 1.7 Cautions Please be well informed of the cautions below before installation. Safety . To avoid the risk of electric shock or product malfunction, keep fingers and metallic objects away from the unit during operation. 3. 2 설치 상 주의사항...
  • Page 8  Keep at least 20cm distance between the Unit and the static charged object. 2. 2 Purging and moving into CR(Clean Room)  Purging ASG-PG series is packaged after purging in our clean room to remove dust. However, if needed, execute purging process according to the below. 1) Install the unit.
  • Page 9 DONG IL TECHNOLOGY LTD 2. 3 Wiring diagram Power cable...
  • Page 10 DONG IL TECHNOLOGY LTD 2.3 Wiring Diagram <ASG-PG Series PLC Circuit Diagram> RED: +24Vdc 24Vdc INPUT 5.6kΩ White: Alarm signal Black: GND Y ellow: PLC on/of f Signal Connection without PLC 1) Connect the black and yellow cables to field ground.
  • Page 11 DONG IL TECHNOLOGY LTD 2.4 Installing main body Installation order ① Assemble the brackets firmly into a main body Warning!! If you fix the Unit without using the brackets in package, be careful the weight not to be applied on the side cover, which can result in air leakage ②...
  • Page 12 DONG IL TECHNOLOGY LTD 2.4 Installing main body ④ Connect power cable Warning!! For guaranteed performance, make sure that GND line of the power cable should be earthed. ⑤ Feed the air 6 mm diameter tube is used in ASG-PG. Connect tube by pushing it through air fitting until you hear ‘click’...
  • Page 13 Our ASG-PG Series are ionization devices using Corona Discharge method. Ion emission and ion balance are subject to operation environment, please make yourself familiar to the device,...
  • Page 14 An emitter pin (inside a emitter) is a sharp, pin-shaped object, made from tungsten. ASG-PG series produces ions using corona discharge method. Thus, during an operation, high voltage is applied on its emitter pin, which rounds the sharp pin away as the time goes on.
  • Page 15 DONG IL TECHNOLOGY LTD 3. 2 How to clean and replace emitters  How to clean an emitter ① Prepare soft brush or cotton swab with alcohol. (No acetone) ② Power off the device and stop the air input. ③ Wipe out the white ‘Fuzzy ball’ on the end of the emitter pin softly enough not to damage or scratch it.
  • Page 16 DONG IL TECHNOLOGY LTD Trouble Shooting Problem Inspection 1) Check that the power cable is connected correctly.(refer Not power on p.9) 1) Check yellow cable is connected to ground. Even if you don’t use PLC, yellow cable should be Alarm LED is blinking in red connected to ground.
  • Page 17 Warranty We, Dong Il Technology Ltd. Manufactured this product under a strict quality control system and warrants it for1 year of period from the shipment date. However, we don’t have any responsibility for 1) Any damage if the product is used in a way different from that is explained in this manual or remade by users arbitrarily.

This manual is also suitable for:

Asg-p025g