fluidra Jandy JXiQ 200 Installation And Operation Manual

fluidra Jandy JXiQ 200 Installation And Operation Manual

Gas-fired pool and spa heater
Table of Contents

Advertisement

JXiQ
Gas-Fired Pool and Spa Heater
Model Size 200, 260, 400
ASME Compliant Model Size 260 & 400
WARNING |
IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed
where such state or local requirements exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with sufficient experience in
pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices
and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or
operation can create carbon monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Zodiac
Pool Systems LLC strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces. Improper installation
and/or operation may void the warranty.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage,
personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Immediately switch off main gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Jandy JXiQ 200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for fluidra Jandy JXiQ 200

  • Page 1 Installation and Operation Manual JXiQ Gas-Fired Pool and Spa Heater ™ Model Size 200, 260, 400 ASME Compliant Model Size 260 & 400 WARNING | IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists.
  • Page 2: Table Of Contents

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Table of Contents Section 1. Important Safety Instructions and Section 6. Electrical Connections ....35 General Information ....... 4 Service Access ..........36 Safety Instructions ........4 Main Wiring Connections ......
  • Page 3 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Section 12. Professional Service and Maintenance ......55 12.1 Header Bypass Reassembly Recommendations ........55 Section 13. Spare Parts ........56 13.1 Major Components ........56 13.2 Cabinet Assembly Spare Parts List and Exploded Parts Diagram ......
  • Page 4: Important Safety Instructions And General Information

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 1. Important Safety Instructions and General Information This manual provides safety, installation and operation instructions for the Jandy JXiQ pool and spa gas heater product line. READ THE SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
  • Page 5: Warranty

    The blower draws air and fuel through specially Details are included with this heater. designed orifices, delivering a precise mixture to the burner, located inside the sealed combustion Make all warranty claims to a Fluidra dealer or ® chamber. Water flows through the heat exchanger, directly to the factory.
  • Page 6: Specifications

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Specifications SUPPLY GAS NATURAL GAS (NG) CERTIFIED INDOOR, OUTDOOR / COVERED SHELTER Installation Location* LIQUID PROPANE (LP) OUTDOOR / COVERED SHELTER Outdoor Operation OUTDOOR OPERATION IN AMBIENT AIR DOWN TO Ambient Air 40°F (4°C) NATURAL GAS (NG)
  • Page 7: Dimensions

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Dimensions Versa Plumb Inlet ® 26.5 in 26.5 in (67 cm) (67 cm) Inlet Sacrificial 24.9 in 24.9 in Anode (63 cm) (63 cm) 18.5 in 18.5”...
  • Page 8 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ All Jandy heaters must be installed in accordance with the local building and installation codes as per the utility or Authority Having Jurisdiction (AHJ). In the absence of local codes, please refer to the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA54, and/or Natural Gas and Propane Installation Code, CSA B149.1.
  • Page 9: Heater Components

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Heater Components tooltip tooltip tooltip Header Monitors temperature at the exhaust flue. If Senses water temperature by Flue Temperature Sensor Pool/Spa Water Temperature Control Indicates a safety control equipped to protect internal components and extend the life of the heater. excessive temperatures are detected, means of a thermistor.
  • Page 10: Getting Started

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Water Pressure Switch: Senses whether or not water is available to the heater by measuring back pressure at the header inlet. If insufficient pressure is detected, the display will indicate a “Check Flow” fault and combustion will stop.
  • Page 11: Package Contents

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Package Contents For ASME compliant heater models JXiQ400NC, JXiQ400PC, JXiQ260NC, JXiQ260PC, JXiQ400NS, JXiQ400PS, JXiQ260NS, and JXiQ260PS please see Section Appendix A. ASME Compliant Header. ® Before completely unpacking the unit please inspect carton for damage.
  • Page 12: Required Equipment

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Required Equipment Please ensure that the following equipment is available to the installer at the time of installation. 2.2.1 Tools Safety Eyewear Gloves Phillips Screwdriver Flathead Screwdriver Pipe Wrench Adjustable Wrench...
  • Page 13: Location Requirements

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Section 3. Location Requirements Clearances The heater must be installed in a location that The JXiQ heater is shipped from the factory with allows clearances for maintenance and inspection. an exhaust vent configured for outdoor installation.
  • Page 14: Outdoor Installation

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Figure 2. Clearances Outdoor Installation other combustible and non-combustible materials. Some local installation codes may have Locate the heater: requirements that exceed those of the installation •...
  • Page 15 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ If the heater is installed close to a structure, protect it from rain water runoff with rain gutters on the roof or other measures. The area under an Be sure to divert rain water runoff away from heater overhang must be open on three sides to...
  • Page 16 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Drill a hole in the concrete using the lower anchor bracket hole as a guide. It is advised that Anchor Bracket Upper a hammer drill with an appropriate concrete drill Retaining Nut bit be used.
  • Page 17: Indoor And Outdoor Shelter Installation

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Indoor and Outdoor Shelter Installation When combustion air is supplied directly through an outside wall, each opening should have a Due to the higher risks and hazards of liquid minimum free area of 1 square inch per 4,000 propane (LP) gas, Zodiac Pool System LLC does not BTU/h (1.2 kW) input of the total input rating of all...
  • Page 18 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Greater Than 10 ft. (3 m) 10 ft. (3 m) Listed Vent Cap 2 ft. (61 cm) Min. Height required for any roof surface within 10 ft. ( 3m) 3 ft.
  • Page 19 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ 3.3.2 Direct Air Intake Air Orifice For indoor installations the exhaust In certain applications it may be necessary to supply must also be converted. Order part number R0731100 and follow the intake air directly to the heater.
  • Page 20 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ • Locate the vent terminal at a sufficient horizontal NOTE: Both combustion air and vent piping joints must be sealed appropriately. Connection of distance from any building opening. Take special combustion air and vent piping to the heater care to assure that combustion products do should be serviceable - i.e.
  • Page 21 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ • Do not terminate heater vents near air • Horizontal runs must be sloped upwards away conditioning or air supply fans which could from the heater to a vent terminal at a minimum pick up exhaust flue products, such as carbon of 1/4 in per horizontal foot (2 cm/m).
  • Page 22 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Remove the rain shield. WARNING Remove the remaining two screws securing the Vent pipe materials, sizing, and installation must be as required by exhaust backplate to the exhaust outlet. the National Fuel Gas Code NFPA 54/ANSI Z223.1 or the Canadian ®...
  • Page 23 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Exhaust Outlet Vent Elbow Vent Adapter Increaser t e g o r f o r C a 4" Vent Pipe I I I t e g o r y f o r C a 3.3.6 Indoor and Outdoor Shelter Exhaust Double check that there are no possible leak...
  • Page 24 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Refer to CSA B149 for requirements specific to Canadian installations. Check local installation codes which may require greater minimum distances from windows and doors to be maintained. 12 in (30 cm) min.
  • Page 25: Gas Connections

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ in the event of a blocked vent. An outside draft IMPORTANT inducer must be installed to pull and create negative pressure in the vent system. Refer to ANSI Z223.1 In the Commonwealth of Massachusetts, additional requirements, ®...
  • Page 26: Supply Gas Requirements

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Supply Gas Requirements Maximum Equivalent Pipe Length (Sch 40 Metallic Pipe) Natural Gas 1000BTU/FT — 0.60 Specific Gravity @ 0.5 in. W.C. Pressure Drop Propane Gas 2500BTU/FT —...
  • Page 27: Inlet Gas Pressure Test

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Inlet Gas Pressure Test Connect Hose to Before operating the heater it is necessary to test the Barbed Adapter input gas pressure to ensure that it falls within the required range as outlined in Table Supply Gas Input Pressure Requirements.
  • Page 28: Water Connections

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Pump Sizing IMPORTANT For ASME compliant heater models JXiQ400NC, For ALL installations the combustion air openings requirements JXiQ400PC, JXiQ260NC and JXiQ260PC please and NFPA54 / ANSI Z223.1 MUST be followed for safe and proper see Section Appendix A.
  • Page 29: Plumbing Connections

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ 20.0 i 200K BTU Heater JXi 260K BTU Heater 18.0 JXi 400K BTU Heater JXi VersaFlo™ Bypass 16.0 14.0 12.0 10.0 Flow Rate (GPM) Figure 10. Head Loss Chart NOTE: In order to properly establish head loss at flow for For ASME compliant heater models JXiQ400NC, a filter, remember that a “dirty”...
  • Page 30 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 5.2.1 Reversing Plumbing Connections There are two options for water inlet connections on the JXiQ. Both configurations use the same water The JXiQ heater is shipped with the manifold on outlet to return heated water to the pool.
  • Page 31: Sacrificial Anode Replacement

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ NOTE: Zodiac Pool Systems LLC recommends Weld-On ® To avoid an electrical shock hazard, which can result in serious injury 724TM PVC to CPVC Cement to glue Schedule 40 or death, ensure that all electrical power to the system is turned off PVC.
  • Page 32: Water Pressure Switch Adjustment

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Guide the anode wire through the grommet. heater water connections are outside this range Consult your local Zodiac representative for ® Attach the anode bonding wire ring terminal to recommendations.
  • Page 33: Check Valve Installation

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ With your fingers, turn the adjustment sprocket A pressure relief valve is not supplied with the JXiQ very slowly clockwise until the heater goes off. heater.
  • Page 34 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Header Heater Revision “L” and Later Figure 14. Remove Drain Plug/Temp Sensor Locate the threaded boss on the outlet port of the header, and find the dimple at the center. Use the dimple to center the drill bit.
  • Page 35: Auxiliary Components, Chlorinators, Ozone Generators And Sanitizing Chemicals

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Install a discharge pipe from the pressure relief Auxiliary Components, Chlorinators, valve discharge opening to a safe area. This is a Ozone Generators and Sanitizing precaution to prevent the possibility of personal Chemicals injury or property damage in the event scalding...
  • Page 36: Service Access

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ NOTE: Before the raceway can be rotated for the first WARNING time a shipping zip tie must be cut. This zip tie is threaded at the raceway release point see item (a). ELECTRICAL SHOCK HAZARD.
  • Page 37: Bonding

    MOTOR Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ IMPORTANT Maintenance Disconnect Means - The National Electrical Code (NEC ) requires one or more means to simultaneously ® ® USER disconnect all ungrounded conductors to be provided for all utilization INTERFACE equipment other than lighting.
  • Page 38: Optional Remote Controls

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 7. Optional Remote copper conductor not smaller than an 8 AWG (6 AWG in Canada). Controls Additionally, Zodiac Pool Systems LLC, requires The JXiQ heater controls can be wired for remote that the appliance be connected to a bonding loop operation.
  • Page 39: Connecting To An Aqualink Control System Or Remote Tstat (2-Wire Connection)

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ • Press and hold MENU, then the POOL and SPA CAUTION buttons for 5 seconds to access Service Setup mode. To avoid damage to the heater, do not connect the power supply of the heater to the output side of the clock if NOTE: The display will revert back to OFF 2 minutes after your time clock simply interrupts the high voltage power supply or has...
  • Page 40 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ NOTE: Only an AquaLink RS System with firmware ® revision “N”, or higher, will support the heater RS Control interface. Refer to Table AquaLink RS Power Indoor Controller System Center Board Identifying Features along with...
  • Page 41 • Press the POOL, SPA, and MENU buttons RS485 connector, as shown in figure 22. Contact simultaneously for 5 seconds. Fluidra customer service for a ferrite kit (PN# R1029700), provided free of charge. (Ferrite • From the Service Menu, scroll down to the WATER specs: Fair-Rite PN# 0431164281).
  • Page 42: Pairing

    27.0° Figure 23. Open Fluidra Pro Time to te Outlet water temp 47.4° Remote s Gas pressure Not Low Log into Fluidra Pro app using your User Id and Gas valve Total cycl SAFETY LOOP password. PRE-IGNITI Schedule Customers Claims...
  • Page 43: Operating Instructions

    Schedule Customers Claims Support Menu under water. Figure 28. Fluidra Pro JXiQ Diagnostics First-Time Start-Up Procedure Section 9. Operating Instructions WARNING Follow the instructions outlined below to start Vent pipes and heater tops get hot! These surfaces can cause serious the heater.
  • Page 44: To Turn Off Gas To The Heater

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ • When the heater starts, confirm there is adequate NOTE: If the heater does not start, check that the filter pump is ON, the filter is clean and that water is water flow.
  • Page 45: Normal Operation

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Normal Operation To Program the Display Language Heater must be in OFF mode to begin During normal operation, the control system measures the temperature of the water flowing POOL Hold for 5 Seconds MENU...
  • Page 46: Performing Seasonal Shutdown

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ To Program Display Light to Turn Off Automatically Temperature Set Point Lock Heater must be in OFF mode to begin Once you have programmed pool temperature and spa temperature set points, you can lock them so POOL that they may not be changed inadvertently.
  • Page 47: Section 10. Maintenance

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Section 10. Maintenance 10.1 Water Chemistry Proper Water Balance is the key to the enjoyment If the heater is not going to be used for an extended of your pool or spa experience and to the long life period of time and in colder climates, follow seasonal of your heater.
  • Page 48: Swimming Pool Energy Saving Tips

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 10.1.1 Saturation Index pool’s water chemistry can make the water less enjoyable to bathe in and result in permanent PH, Total Alkalinity (TA), temperature, Calcium damage to your heater and/or complete failure of Hardness and Total Dissolved Solids (TDS) play individual components.
  • Page 49: Winterizing

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ • Where possible, shelter the pool from prevailing 10.4 Spring Start-up winds with well-trimmed hedges or other When winterized, the heater should be reassembled landscaping, cabanas, or fencing. by a qualified professional technician in the Spring.
  • Page 50 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 10.5.1 Guidelines for Homeowner Inspection: • An ignition sequence should start shortly after the pump is turned back on. WARNING • Inspect the thermal regulator valve (TRV). Do not store or use gasoline or other flammable vapors, liquids or •...
  • Page 51: Section 11. Troubleshooting

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Section 11. Troubleshooting call Jandy Technical Support at 800.822.7933, or visit www.jandy.com. 11.1 Common Problems The following table lists some of the most common problems when running the heater. Most problems Zodiac Pool Systems LLC strongly recommends occur when the heater is started for the first time that you call a qualified service technician to perform...
  • Page 52: Service Diagnostic Messages

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Symptom Possible Cause Remedy Heater pounding or Water flow through heater too Look for obstruction or closed valve in system. knocking low. Check for damaged internal bypass. Failed Thermal Regulating Valve Variable speed pump set too low (TRV).
  • Page 53 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Fault Code Possible Cause Recommendations CHECK LOUVER If this feature is enabled, it means If feature is NOT being used: the louver isn't registering in the •...
  • Page 54 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Fault Code Possible Cause Recommendations CHK HEAT EXCHANGER Flue temperature in excess of 400° Check for sooting on outside of heat exchanger for > 5 minutes. tubes or anything that can inhibit water flow through the heat exchanger which can also cause other error codes to appear.
  • Page 55: Ignition Control Led Service Codes

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ 11.3 Ignition Control LED Service Codes WARNING The LEDs on the ignition controller are used to SERVICING SAFETY provide updates on the status of the controller. See Service procedures can be hazardous because they involve fuel gas, the table below for descriptions of the status LEDs.
  • Page 56: Section 13. Spare Parts

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 13. Spare Parts Zodiac does not sell parts directly to pool owners, so when it’s time for maintenance, please see Using genuine Zodiac factory replacement parts your local Preferred Professional Provider (PPP) helps to ensure the ongoing quality and reliability of of genuine parts.
  • Page 57: Cabinet Assembly Spare Parts List And Exploded Parts Diagram

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ 13.2 Cabinet Assembly Spare Parts List and Exploded Parts Diagram For ASME compliant heater models JXiQ400NC, JXiQ400PC, JXiQ260NC and JXiQ260PC please see Section Appendix A. ASME Compliant Header.
  • Page 58: Heat System Spare Parts List And Exploded Parts Diagrams

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 13.3 Heat System Spare Parts List and Exploded Parts Diagrams The following JXiQ Models are equipped with a Cupronickel (CuNi) heat exchanger. • JXiQ400NN, JXiQ400PN 13.3.1 Combustion Chamber Assembly For ASME compliant heater models JXiQ400NC, JXiQ400PC, JXiQ260NC and JXiQ260PC please see Section Appendix A.
  • Page 59 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Page 59...
  • Page 60 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 13.3.2 Burner Assembly Model 200 Model 260 Model 400 Description **LP Blower Assembly Kit R0591100 R0591100 R0591100 R0591100 R0591100 R0591100 Air Intake Grate Kit R0591200 R0591200 R0591200 R0591200...
  • Page 61: Water System Spare Parts List And Exploded Parts Diagrams

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ 13.4 Water System Spare Parts List and Exploded Parts Diagrams For ASME compliant heater models JXiQ400NC, JXiQ400PC, JXiQ260NC and JXiQ260PC please see Section Appendix A. ASME Compliant Header.
  • Page 62 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Header Type “A” Header Type “A” (Discontinued) (Discontinued) 10 9 Page 62...
  • Page 63: Electrical System Spare Parts List And Exploded Parts Diagrams

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ 13.5 Electrical System Spare Parts List and Exploded Parts Diagrams Description Model 200 Model 260 Model 400 Transformer Kit R0456301 R0456301 R0456301 User Interface Kit R0988800 R0988800 R0988800...
  • Page 64: Section 14. Appendix A. Asme

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ Section 14. Appendix A. ASME Compliant Header ® Please use the information below for the following ASME compliant heater Models, JXiQ400NC, JXiQ400NS, JXiQ400PC, JXiQ400PS, JXiQ260NC, JXiQ260NS, JXiQ260PC and JXiQ260PS. The corresponding sections from the manual are cross referenced with page numbers at the beginning of each section.
  • Page 65: Pump Sizing

    Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ 14.3 Pump Sizing Item Description Qty. JXiQ Heater (From Section Pump Sizing at front of manual) Connector Flange All JXiQ heaters utilize an internal bypass mechanism 2"...
  • Page 66 ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 14.3.1 Water Inlet Piping • Return all valves to their operating positions. • Restore power to the heater at the breaker. (From Section Water Inlet Piping at front of manual) •...
  • Page 67 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ Prior to installing or replacing this pressure relieve valve (PRV), ensure the following steps have been completed. • Turn off the electrical power to the heater. •...
  • Page 68: Cabinet Assembly Spare Parts List And Exploded Parts Diagram

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 14.4 Cabinet Assembly Spare Parts List and Exploded Parts Diagram (From Section 13.2 Cabinet Assembly Spare Parts List and Exploded Parts Diagram) Description Model 260 Model 400 Heater Jacket Top Kit (no User Interface) R0592400...
  • Page 69 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ 14.4.1 Combustion Chamber Assembly (From Section 13.3.1 Combustion Chamber Assembly) Description Model 260 Model 400 Exhaust Elbow Assembly Kit R0590200 R0590200 Band Clamp Kit R0590400 R0590400 Refractory Kit, Internal R0590500...
  • Page 70: Water System Spare Parts List And Exploded Parts Diagrams

    ENGLISH Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ® ™ 14.5 Water System Spare Parts List and Exploded Parts Diagrams (From Section 13.4 Water System Spare Parts List and Exploded Parts Diagrams) Description Model 260 Model 400 Thermal Regulator Valve Access Plate Kit R0820400...
  • Page 71 Jandy JXiQ Gas-Fired Pool and Spa Heater | Installation & Operation Manual ENGLISH ® ™ NOTES Page 71...
  • Page 72 Zodiac Pool Systems Canada, Inc. 2-3365 Mainway Burlington, ON L7M 1A6, Canada Jandy.ca | 1.800.822.7933 A Fluidra Brand ©2023 Zodiac Pool Systems LLC. All rights reserved. ZODIAC is a registered trademark of Zodiac International, ® S.A.S.U., used under license. All other trademarks are the property of their respective owners.

This manual is also suitable for:

Jandy jxiq 260Jandy jxiq 400Jxiq200nk

Table of Contents

Save PDF