Quick Links

Access & Power Integration
Altronix/SALTO Kits
Models Include:
T1SAK3F4
4 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove1 enclosure with TSA1 Altronix/SALTO backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) ACM4 - Fused Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Fused Power Distribution Module
T2SAK7F8
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TSA2 Altronix/SALTO backplane
- (1) eFlow104NB - Power Supply/Charger
- (1) ACM8 - Fused Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Fused Power Distribution Module
T2SAK75F12
12 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with TSA2 Altronix/SALTO backplane
- (1) eFlow104NB - Power Supply/Charger
- (1) eFlow102NB - Power Supply/Charger
- (1) ACM8 - Fused Access Power Controller
- (1) ACM4 - Fused Access Power Controller
- (1) PDS8 - Dual Input Fused Power Distribution Module
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
Installation Guide
All registered trademarks are property of their respective owners.
Rev. TSAK_032919
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
T1SAK3F4D
4 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove1 enclosure with TSA1 Altronix/SALTO backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) ACM4CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input PTC Power Distribution Module
T2SAK7F8D
8 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2 enclosure with TSA2 Altronix/SALTO backplane
- (1) eFlow104NB - Power Supply/Charger
- (1) ACM8CB - PTC Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8CB - Dual Input PTC Power Distribution Module
T2SAK75F12D
12 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2 enclosure with TSA2 Altronix/SALTO backplane
- (1) eFlow104NB - Power Supply/Charger
- (1) eFlow102NB - Power Supply/Charger
- (1) ACM8CB - PTC Access Power Controller
- (1) ACM4CB - PTC Access Power Controller
- (1) PDS8CB - Dual Input PTC Power Distribution Module
More than just power.™

Advertisement

loading
Need help?

Need help?

Do you have a question about the SALTO TROVE T1SAK3F4D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Altronix SALTO TROVE T1SAK3F4D

  • Page 1 4 Door Kit with PTC Outputs Fully assembled kit includes: Fully assembled kit includes: - Trove1 enclosure with TSA1 Altronix/SALTO backplane - Trove1 enclosure with TSA1 Altronix/SALTO backplane - (1) eFlow6NB - Power Supply/Charger - (1) eFlow6NB - Power Supply/Charger...
  • Page 2: Configuration Chart

    Install the three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the Fig. 1 tamper switch bracket onto the edge of the enclosure approximately 2”...
  • Page 3 OUT7 OUT8 COM (--- ) HS4 Module COM (--- ) Pan Head Screw PWR2 + PWR2 + Common Power Outputs (NEG) Altronix VR6 is mounted under PDS8 Altronix eFlow6NB TRIGGER INPUT IN GND IN GND IN GND IN GND Altronix ACM4(CB)
  • Page 4 PWR1 + Altronix PDS8(CB) OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8 COM (--- ) COM (--- ) PWR2 + PWR2 + Common Power Outputs (NEG) Altronix VR6 is mounted under PDS8 - 4 - Trove SALTO Kits Installation Guide...
  • Page 5 3. Mount backplane to enclosure with hardware. Access Controller Position Chart for the Following Models: SALTO Access Controller Pem Mounting CU42E0, CU4200 or CU4EB8 Fig. 4 Fig. 4a Backplane Altronix eFlow104NB Spacer HS4 Module Pan Head Screw AC DC 1 min enable NO NC TRIGGER EOL...
  • Page 6 - UL Listed in the U.S. and Canada. - Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN. - Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.
  • Page 7 T1SAK3F4(D) Enclosure Dimensions (H x W x D): 18” x 14.5” x 4.625” (457mm x 368mm x 118mm) 14.5” (321.3mm) 7.25” (184.2mm) 1.45” (36.8mm) 1.95” (49.5mm) 4.5” (114.3mm) 13.0” (330.2mm) 1.25” (31.8mm) 1.25” (31.8mm) 1.5” (38.1mm) 1.5” (38.1mm) 0.6” (15.2mm) 0.57”...
  • Page 8 5.25” (133.4mm) Altronix is not responsible for any typographical errors. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IITrove SALTO Kits E22W MEMBER - 8 -...

This manual is also suitable for: