Read this manual carefully before installing, operating,
servicing or repairing.
Working environment:
1.Using these tools in any potentially explosive environment is strictly prohibited.
2.It is always recommended that these types of tools must be operated when
3.Always use these tools in a well ventilated area.
4.Slipping, stumbling and falling are the major causes of potential serious injury,
therefore, a clean and clutter free surface in the working area before operating
the tools is strongly recommended.
Air supply and connection requirements:
1.The maximum recommended air pressure during operation must not exceed
90 psi (6.3bar). Higher air pressure may create unsafe operating conditions for
the tool and the user.
may still condense in the piping or hose and will enter the tool mechanism
causing premature damage to the tool. Therefore, it is recommended to install
3.Always use an air compressor of the proper capacity to operate each tool.
4.Clean the hose with a blast of compressed air before connecting the hose to
the air tool. This will prevent
both moisture and dust inside the hose from
entering the tool and causing possible rust or malfunction.
Warning:
1. This tool should only be used as a hand operated tool. It is powered by compressed
air and is not insulated against electric shock.
2. This tool is specially designed for chipping away surface materials or objects. Any
application or use of this tool other than what it is designed for is strictly prohibited.
3. High sound levels may cause hearing damage. Always wear hearing protection
when operating this tool.
4. User must wear proper clothing. Loose clothing, long hair, stings, straps, belts and
jewelry should not be worn when operating this tool.
5. Wearing eye/face protection can reduce the danger of high-speed materials being
ejected by the tool.
6. Working with certain materials may create emission of dust and fumes, which may
cause a potential explosive environment and a hazard to the health. Wearing correct
breathing protection and taking some preventive measures are recommended.
position while operating this tool.
8. Using this tool will cause the ejection of particles when chipping or demolishing.
Make sure there is no bystander within the vicinity of working area.
stead of free hand, to hold the chisel when necessary.
this tool.
11.Make sure that the direction of the chips generated from the chisel is properly
directed so as not to create a hazard.
12.Always turn off the air supply and disconnect the air hose before changing the
chisel or making adjustments on this tool.
13.Release the throttle trigger to avoid danger if there is a failure of energy supply and
when connecting or disconnecting the air hose.
Working environment:
Oil Filter
Filter ,Regulator&Lubricator
Shut-Off Cock
Shut-Off Cock
Refrigerated Air Dryer
Air Tank
Piping diameters and length requirement:
The diameter ΦB required for the branch pipe (from
.
ΦA.
ΦB = 2 x ΦA
The diameter ΦC required for the primary air supply (from
large as ΦA. ΦC = 3 x ΦA
The length for the inlet pipe
should be less than 15 feet (4.5m).
14.Beware if the compressed air hose breaks unexpectedly, or is being connected or
disconnected improperly. This whipping action may cause injury.
15.Prolonged use will cause user fatigue. Periodic breaks are recommended for user
safety.
16.It is recommended to stop operating the tool whenever the user experiences
discomfort, tingling or pain during use.
17.Make sure there is no gas or combustible material stored near the tool when
servicing, changing chisel, or storage.
18.Avoid storing this tool where it is subject to high humidity.
Maintenance:
1. Before connecting the air hose to this tool or after operating, apply 4 or 5 drops of
pneumatic oil into the air inlet and run it for several seconds, referring this operation
to the attached picture.
2. Maintain this tool regularly by performing the same oiling application every 3 to 4
hours of operation.
3. Do not lubricate tools with flammable or volatile liquids. Use only the lubricant
recommended by Mighty-Seven or authorized dealers. Any other lubricant will
lead to reduce performance of the tool and permanent damage. Whenever any
pneumatic oil.
4. Follow all the recycling laws of waste disposal once this tool is no longer usable.
Air Tool
Original Language
Serial Number: Please refer to the tool
Air Hammer
Water Drain
Item No.: SC-371C
Pressure Check Point
relevant provisions of Machinery Directive 2006/42/EC and its amendment and
is manufactured and tested according to the following standards:
EN ISO 11148-4 / EN ISO 15744 / EN ISO 28927-11
Declared in: Taichung, Taiwan
Dated:2021/10/01
Air Compressor
Manufacturer:
Mighty Seven International Co., Ltd.
No. 70-25,Ching Qunag Rd., Wu-Jih Shiang,
Taichung Hsien, 41466 Taiwan
to
) should be 2 times as large as
www.mighty-seven.com
to
) should be 3 times as
Pneumatic oil
Regular maintenance
CE DECLARATION OF CONFORMITY
Signature
Jay Lin
Declared by: QA Manager
King Tony Europe
3 Rue des imprimeurs ZI République Nord 1.
86000 POITIERS FRANCE
TEL : (+33) 5-49-30-30-90
E-MAIL : christian.aubineau@kingtony.eu
Air inlet
Need help?
Do you have a question about the SC-371C and is the answer not in the manual?
Questions and answers