Add a 4-port NIC Card to the Web Gateway WBG-5000-E2 and
WBG-5500-E2 Appliances
Beginning in Q1 2022, the Web Gateway WBG-5500-E2 and WBG-5000-E2 appliances come equipped with four ports.
This marks a change from the previous WBG-5500-E and WBG-5000-E models, which had six ports. One of the
supported I/O modules is pre-installed on riser 1, located farthest from the PSU.
If desired, an additional supported 4-port fiber card can be added to increase the port count to eight. The add-on fiber
card must be inserted into riser slot 2, which is closest to the PSU.
For a comprehensive list of supported fiber cards, refer to the
Hardware
Guide.
Steps to install the additional 4-port fiber card:
1. Turn off the appliance and detach the power cables.
2. Detach the network cables from the NIC ports module.
3. Remove the tamper-proof label.
4. Remove the system top cover:
a. Loosen the two captive thumb screws located on the back of the system cover.
b. Slide the system top cover back.
c. Lift the cover upward.
5. Remove the riser card. Grasp the riser card #2 assembly, closest to the PSU, and carefully pull straight up.
6. Remove the filler panel from the add-in card slot. See Additional NIC illustration 1 - A in the Related Information
section.
7. Remove the one fastener screw from the riser card. See Additional NIC illustration 1 - B in the Related Information
section.
8. Insert the add-in card in the slot on the riser card until is fully seated. See Additional NIC illustration 2 - C in the
Related Information section.
9. Secure the add-in card to the riser bracket with the fastener screw. See Additional NIC illustration 2 - D in the
Related Information section.
10. Position the riser card edge connector over the riser slot on the server board.
11. Align the two hooks on the back edge of the riser assembly with the slot on the back of the chassis.
12. Once aligned, carefully press the riser assembly straight down into the riser slot.
IMPORTANT: Don't rock the riser assembly into place; doing so might damage the contact pins within the riser
slot.
https://success.skyhighsecurity.com/Skyhigh_Secure_Web_Gateway_(On_Prem)/Information_about_Secure_Web_Gateway...
"Adding a module
card" section of the
Downloaded: Wed, 10 Apr 2024 20:03:22 GMT
Web Gateway
1