BD Pyxis iMX113 Service And Maintenance Manual

Es refrigerator tower
Hide thumbs Also See for Pyxis iMX113:

Advertisement

Quick Links

iMX113 BD Pyxis™ ES Refrigerator Tower
Service and Maintenance Manual
April 2024
360396 REV G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pyxis iMX113 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BD Pyxis iMX113

  • Page 1 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual April 2024 360396 REV G...
  • Page 2 BD and Helmer Scientific. BD and Helmer Scientific assume no responsibility or liability for any errors or inaccuracies that may appear in the informational content contained in this material. For the purpose of clarity, BD and Helmer Scientific consider only the most recent revision of this document to be valid.
  • Page 3: Table Of Contents

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Contents About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Intended Audience .
  • Page 4 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Alarm Tests .
  • Page 5: About This Manual

    Intended Audience This manual is intended for use by end users of the iMX113 BD Pyxis ES Refrigerator Tower. For information on how to use the Pyxis MedStation™ ES which provides medication management capabilities to the iMX113 BD Pyxis ES Refrigerator Tower, please refer to the Pyxis MedStation™...
  • Page 6: Avoiding Injury

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual The following symbols may be found on the refrigerator or refrigerator packaging: Caution: Risk of damage to equipment or Earth / ground terminal danger to operator Caution: Hot surface Protective earth / ground terminal...
  • Page 7: Model And Input Power

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual 1 .5 Model and Input Power Note Service information varies depending on the model and power requirements. Table 1 . Model and Input Power Current Model Voltage Frequency Draw 60Hz 2.3A...
  • Page 8: Installation And Configuration

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Installation and Configuration 2 .1 Location Requirements Keep all ventilation openings in the enclosure or, in the structure for building-in, clear of obstruction. ♦ Grounded outlet meeting the electrical requirements listed on the product specification label.
  • Page 9: Connect Back-Up Power

    2 .3 Connect Back-Up Power The iMX113 BD Pyxis ™ ES Refrigerator Tower is equipped with a back-up battery system. The back-up battery is located on top of the refrigerator. The back-up battery system provides electrical power to the i.C temperature monitoring system, alarm system, and magnetic door lock.
  • Page 10: Module Installation

    • Use caution when installing additional modules to avoid pinching fingers or hands between modules. Modules can be added to the BD Pyxis™ ES Refrigerator Tower for additional compartmentalized storage. Module service kits are available in standard and deep sizes. Contact Pyxis Technical Support Center for module service kits. Installation instructions are provided with the service kit.
  • Page 11: Configure Storage

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual 2.7 Configure Storage NOTICE • Before moving bins, ensure they are completely empty for safe removing. Notes • Before moving storage components, protect stored items in refrigerator from extended exposure to adverse temperature.
  • Page 12: Controls

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Controls The iMX113 BD Pyxis™ ES Refrigerator Tower is equipped with the i.C temperature monitoring and control system. The i.C system combines temperature control and monitoring into a single user interface.
  • Page 13: Alarm Reference

    • The Settings screen is password protected. If viewing settings for the first time, enter factory default password of “1234”. • Settings appearing in the column on the right are not visible when the BD Pyxis™ ES Refrigerator Tower is connected to the MedStation.
  • Page 14 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Temperature Setpoint The setpoint is the temperature at which the refrigerator operates. Notes • The Settings screen is password protected. If viewing settings for the first time, enter factory default password of “1234”.
  • Page 15 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Temperature History The Temperature History screen displays a graph showing the temperature history of the Primary Monitor probe. The graph may be viewed in a one-day or seven-day format. The zoom feature may be used to allow a more detailed view of a particular segment of the temperature graph.
  • Page 16 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Change Password The Administrator password can be changed by selecting the Change Password button. Notes • The factory preset password is “1234”. • Once the password is changed, ensure the new password is recorded and kept in a safe place.
  • Page 17 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Factory Default Settings Settings listed below may be simultaneously returned to factory default values. NOTICE Ethernet port must be ON to communicate with the MedStation. Note Some factory default settings may not be the same as the settings that were factory-calibrated before the refrigerator was shipped.
  • Page 18: Maintenance

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Maintenance Maintenance tasks should be completed according to the schedule below. NOTICE Maintenance should only be performed by trained refrigeration technicians. Notes • The preventive maintenance schedule provides recommended minimum requirements. Regulations or physical conditions at your organization may require maintenance items be performed more frequently, or only by designated service personnel.
  • Page 19: Alarm Tests

    Alarm Tests Test alarms to ensure they are working correctly. The BD Pyxis™ ES Refrigerator Tower has alarms for chamber temperature, compressor temperature, power failure, probe failure, and door open (time). Alarms can only be tested when the refrigerator is not connected and communicating with the MedStation.
  • Page 20: Sensor Calibration

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Power Failure Alarm Test Note During a power failure, the power failure alarm sounds and the battery provides power to the monitoring system and magnetic lock. 1. Change the Power Failure delay setting to 0 minutes by touching + or – on the Power Failure spin box to change the value to 0.
  • Page 21: Upgrade System Firmware

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Note Using putty to seal the probe hole when using a thermocouple wire to calibrate is recommended. Calibrate Primary Monitor Probe 1. Ensure the Primary Monitor Probe is securely installed in the ballast 2.
  • Page 22: Condensate Heater

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual 4 .4 Condensate Heater NOTICE The condensate evaporator and water evaporation tray are hot. Check Condensate Heater 1. Using a #2 Phillips screwdriver, loosen and remove the six (6) screws securing the cover of the electrical box. Remove the cover and set aside.
  • Page 23: Led Lamp Strip

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual 4 .6 LED Lamp Strip Check LED Lamp Strip Ensure the chamber light turns on when the refrigerator door is opened. Remove and Replace LED Lamp Strip 1. Switch the main power switch to OFF; switch the battery back-up and maglock key switches to OFF; disconnect the AC power cord from the power receptacle.
  • Page 24: Re-Apply Silver Conductive Grease To Upper Door Hinge

    To prevent damage to electrical components and to prevent the possibility of electric shock, safely shut down, turn off and unplug all BD Pyxis products before washing them. BD Pyxis products are typically cleaned with mild soap and warm water.
  • Page 25 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual i .C³ Touchscreen ® To remove any dirt or fingerprints from the front surface of displays or touch screens, use an alcohol pad and a clean, lint-free cloth. All electronic areas must be completely dry and free of foreign material before returning the product to service.
  • Page 26 Disconnect refrigerator from AC power when cleaning. Note In environments where the BD Pyxis™ ES refrigerator is exposed to excessive lint or dust, condenser grill may require cleaning more frequently than stated in preventive maintenance schedule. Position the refrigerator to gain access to the back of the unit. Clean the condenser grill using a soft brush and a vacuum cleaner.
  • Page 27: Service

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Service 5.1 Refrigerant Risk of fire or explosion. Flammable refrigerant used. To be repaired only by trained service personnel. DO NOT puncture refrigerant tubing. NOTICE • Review all safety instructions prior to recharging refrigerant.
  • Page 28: Csv Download

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual 5 .2 CSV Download A CSV download captures historical data from the refrigerator and allows it to be placed on a removable storage device. The amount and type of data downloaded will vary depending on whether a User or Tech (Technician) data set is selected.
  • Page 29: Troubleshooting

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Troubleshooting NOTICE Review all safety instructions prior to troubleshooting. 6 .1 Access System Problems Problem Possible Cause Action Door does not lock. Door lock key switch is in the Turn the key to the on “-” position.
  • Page 30: Chamber Temperature Problems

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual 6 .2 Chamber Temperature Problems Problem Possible Cause Action Temperature display Display temperature needs to Follow temperature calibration process. does not match actual be calibrated. temperature. Chamber temperature is too Display temperature needs to Follow temperature calibration process.
  • Page 31: Condensation Problems

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual 6 .4 Condensation Problems Problem Possible Cause Action Excess condensation/ Foreign liquid spilled within Verify liquid products are sealed, wipe up spilled liquid if necessary. moisture inside chamber. chamber. Unit cooler condensation Check level of refrigerator and unit cooler drain pan, level if needed for proper pan is not draining.
  • Page 32: Parts

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Parts Notes • Before replacing parts, protect items in refrigerator from extended exposure to adverse temperature. • Allow refrigerator temperature to stabilize at setpoint after replacing parts or after extended door opening.
  • Page 33 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual NOTICE • Disconnect the refrigerator from AC power before opening the electrical box. • Do not remove the cover from the condensate evaporator tray. Letter Description Volts Part Number Letter...
  • Page 34: Schematics

    BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Schematics (iG) MAIN POWER Reset Bezel Mount 115V~ (±10%) 60Hz Components 230V~ (±10%) 50Hz 230V~ (±10%) 60Hz Speaker TO ETHERNET i.C3 Display PCB i(F) ROUTER PORT 2 USB Host POWER CORD i.C3 LCD...
  • Page 35 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Door information to Control Board. FRONT DOOR FROM J15 SWITCH (401143-1) N.O. FROM J31 - i.C3 CONTROL PCB ETHERNET PORT FROM J6 FROM J9 - 401783-1 (401783-1) 401275-1 CAC/BBB POWER...
  • Page 36 BD Pyxis™ ES Refrigerator Tower Service and Maintenance Manual Compliance 9.1 Regulatory Compliance This device complies with the requirements of the following directives: 2011/65/EU (Restriction of Hazardous Substances), 2014/30/EU (Electromagnetic Compatibility (EMC) Directive), and 2014/35/EU (Low Voltage Directive). This product is certified to applicable UL and CAN/CSA standards by a NRTL.
  • Page 37 Helmer Scientific Becton Dickinson and Company 14400 Bergen Boulevard, Noblesville, IN 46060 USA Franklin Lakes, NJ United States | 201.847.6800 | BD.com 360396/G Copyright © 2024 Helmer, Inc.